EB-MODBUS-RTU
Communication modules for the EasyB series
Version | ||||
---|---|---|---|---|
EB-MODBUS-RTU | ||||
EB-IO-LINK | ||||
EB-IO-LINK1 |
DOWNLOADS
Technical files
Instruction manual
Manual
Dimension sheet
Approvals / Manufacturer's declaration
UL 508 Listed USA (E219022)
UL 508 Listed Canada (E219022)
COC UL 508 & CSA 22.2
Marine DNV GL (TAA000022T)
EU-Declaration of Conformity
CAD/CAE data
3D-CAD-Model (STEP)
Additional information
Brochure EasyB
Technical Data for EB-MODBUS-RTU
For use with | |
---|---|
EB-0824-xxx-x, EB-1824-xxx-x, EB-3824-xxx-x | max. 40 |
Process data | |
---|---|
Number | - |
Content | - |
Signaling | |
---|---|
Isolated group input | "13" Solid State Relay 58 Vdc/ 40 Vac/ 100 mA |
Potential-free signal output | "14" Solid State Relay 58 Vdc/ 40 Vac/ 100 mA |
Potential-free signal output | "24" Solid State Relay 58 Vdc/ 40 Vac/ 100 mA |
Signal output (ON/OFF/Reset) | Reset input Level high = min. 11 Vdc, max. 30 Vdc Level low = min. 0 Vdc, max. 5 Vdc Jitter: +/- 5 %; +/- 5 ms |
Approvals | |
---|---|
Approvals | UL (prepared), DNV GL |
Environment | |
---|---|
Ambient temperature | -13 °F to + 158 °F |
Storage temperature | -13 °F … +185 °F |
Derating | - |
Climatic category | 3K3 |
Required minimum spacing (left/right) | 0.00 inch |
Type of cooling | Natural convection |
Required minimum spacing (over/under) | 1.18 inch |
Relative humidity | 5...96 % without condensation |
Safety and protection | |
---|---|
Protection index | IP 20 |
Safety class | III, without PE connection |
Degree of pollution | 2 |
Terminal and mounting | |
---|---|
Terminals input, (spring clamp terminal) | - |
Terminals interface (spring clamp terminal) | max. 2,5 mm² |
Terminals signalling, (spring clamp terminal) | max. 2,5 mm² |
Mounting position | horizontal for standard rail DIN TS35 |
Measures and weights | |
---|---|
Width | 0.47 inch |
Height | 3.90 inch |
Depth | 2.36 inch |
Weight | 0.09 lbs |
Information for EB-Communication series
General Data
- 18 - 30 Vdc
- 24 Vdc
- Ambient temperature -13 °F / -25 °C … +158 °F / +70 °C
- Protection index IP 20
- Input rated voltage 24 Vdc
- Suppressor diode 33 V
-
17.5 V (Turn-off Threshold 16.7 V),
± 0.7 V - 0.4 W / 0.85 W
- 26 mA
- RTU-Modus, 8Bit, No Parity, 1 Stop Bit, max. bus participants 32
-
Read:-state (tripped, On, Off)
-set/active current
-input voltage
-firmware version/serial number
Write:-state (on, off, reset) - 35 Vdc
- 3 %
- 4,68 ms
Benefits
- Intelligent interface for reading and writing of information of connected EasyB modules
- Automatic feedthrough of all signal levels
- Can be used to adjust tripping current
- EasyB channels switchable individually