4-Channel circuit breaker
PM-0724-400-1
Characteristics
Benefits
› Adjustable tripping current for each output channel via current selector switch
› Ability to turn-on high load capacitance at each channel
› Sequential and load-dependent switching-on of channels
› Comprehensive single-channel-diagnostics and remote switching on/off of each output channel via 2-wire-interface, potential-free signal output or IO-Link
› LED signalisation and remote request for each output channel
› Group alarm contact
› 3 years warranty
| Product | 4-Channel circuit breaker | 
| Order number | PM-0724-400-1 | 
| Series | ECONOMY SMART | 
Input
| Rated input voltage | 24 Vdc | 
| Input voltage range | 18 Vdc to 30 Vdc | 
| Max. continuous current of the module | 40 A | 
| Max. continuous current feed terminal (+) | 40 A | 
| Max. ripple of the feeding input voltage | 3 % | 
| Switch-on threshold | 20.00 V | 
Output
| Rated output voltage | 24 Vdc | 
| Rated Output Current | 10 A | 
| Rated Output Current Adjustable | 2,3,4,6,8,10 | 
| Rated Output Current per Output Channel | 10 A | 
| Output voltage range | 24 Vdc | 
| Number of Output Channels | 4 | 
| Switch-off threshold | 18 V | 
| Max. voltage drop between input and output | 200 mV | 
| Max. power loss | 10 W @ 4 x 10 A | 
| Max. waiting time after switching off an output after an overload (thermal relaxation) | 20 s | 
| Idle current @ 24 V | 35 mA | 
| Max. feedback resistance | 35 Vdc | 
| Power losses in stand-by mode | 0.84 W | 
| Parallel connection of outputs | Not allowed | 
| Series connection of outputs | Not allowed | 
| Release Characteristics | Thermomagnetic characteristic | 
Signaling
| Signal output S2 | 24 Vdc, max. 25 mA (status output channels) | 
| Signal output S3 | 24 Vdc, max. 25 mA (Common signalling output) | 
| Status display | Green, yellow, red LED | 
Environment
| Climate class according to EN 60721 | 3K3 | 
| Ambient temperature | -25 °C to 70 °C / -13 °F to 158 °F | 
| Storage temperature | -25 °C to 85 °C / -13 °F to 185 °F | 
| Humidity without condensation | 5 % to 96 % | 
| Cooling type | natural convection | 
| Required minimum distance (side) | 0 mm | 
| Required minimum distance (top/bottom) | 40 mm | 
Protection and Safety
| Degree of pollution | 2 | 
| Protection class according to EN 61140 | III, without PE connection | 
| Safety extra low voltage (SELV/PELV) | IEC 60364-4-41 (DIN VDE 0100-410) | 
Size and Weight
| Width | 45 mm / 1.77 in | 
| Height | 90 mm / 3.54 in | 
| Depth | 91.5 mm / 3.6 in | 
| Depth incl. DIN TH35 | 122.5 mm / 4.82 in | 
| Weight | 0.2 kg / 0.441 lbs | 
| UR | UL 2367 - Recognized | 
| cULus | UL 508 - Listed | 
 
            
    
                 
         
         
         
         
        