Low profile transformer, safety isolating transformer
FL 14/14014/9 - Discontinued types – not for new designs
Characteristics
Benefits
› Minimum size at high output
› Low height
› Double input voltage for series or parallel connection
› Permanent corrosion protection, high insulation value and maximum electrical reliability thanks to XtraDenseFill resin encapsulation
› Coil shell in 2-chamber technology
› Self-extinguishing potting material
Input
| 1. Eingang |
115 V o |
| 2. Eingang |
115 V o |
| 01. Input voltage | 115 V |
| 02. Input voltage | 115 V |
| Input voltage | 115 V |
| Frequency range | 50 Hz to 60 Hz |
Output
| 1. Ausgang |
9 V o 0.43 A Recommended protection:0,40AT |
| 2. Ausgang |
14 V o 0.22 A Recommended protection:0,250AT |
| 3. Ausgang |
14 V o 0.22 A Recommended protection:0,250AT |
| 01. Output fuse int/ext | Recommended protection: |
| 01. Output fuse | 0,40AT |
| 01. Output voltage | 9 V |
| 02. Output fuse int/ext | Recommended protection |
| 02. Output fuse | 0,250AT |
| 02. Output voltage | 14 V |
| 03. Output fuse int/ext | Recommended protection |
| 03. Output fuse | 0,250AT |
| 03. Output voltage | 14 V |
| 01. Output current | 0.43 A |
| 02. Output current | 0.22 A |
| 03. Output current | 0.22 A |
| Output voltage | 9 V to 14 V |
| Rated output voltage | 9 Vac / 14 Vac / 14 Vac |
General
| Smoothing capacitors SEC I | 1000 µF |
| Smoothing capacitors SEC II | 2 x 220 µF |
| No-Load Voltage (Approx. x Factor) | 1.28 |
| No-Load Losses | 0.31 W |
| Power | 10 VA |
| Phases | 1 |
| Voltage regulator SEC I | 7805 |
| Voltage regulator SEC II | 317L, 337LZ |
| Power loss | 3.41 W |
General
| Switching group | IIii0 |
| Design | Encapsulated |
| Duty Cycle | 100 % |
| Short circuit proof | not short-circuit proof |
| Short circuit voltage uk | 21.6 % |
| Short-Circuit Losses | 3.1 W |
| Wire material | Copper |
| Magnetic axis | lying |
Environment
| Cooling type | AN |
| Storage temperature | -20 °C to 85 °C / -4 °F to 185 °F |
| UL Insulation class | class 105 |
| Ambient temperature | -20 °C to 40 °C / -4 °F to 104 °F |
| Degree of contamination | 2 |
Safety and protection
| Protection class (prepared) | II |
| Protection class (prepared) | II |
| Max. installation height | 1,000 m / 3,281 ft |
| Overvoltage category | III |
| Protection type | IP00 |
Input
| Input terminal | Pin |
Output
| Output terminal | Pin |
| Weight | 0.322 kg / 0.71 lbs |
| Low Voltage Directive | EN 61558-2-6 |
| RoHS compliant | EN IEC 63000 |
| Approval cURus - Recognized | UL 5085-1/-2; CSA 22.2 |
| VDE Approval |
VDE 0570-2-x (DIN EN 61558-2-x) |