UTT1-4-23
Control- and isolating transformer
Rated input voltage
208 Vac/ 230 Vac/ 380 Vac/ 400 Vac/ 415 Vac/ 440 Vac/ 460 Vac/ 480 Vac/ 500 Vac/ 525 Vac/ 550 Vac/ 575 Vac/ 600 Vac
Rated output voltage
2 x 115 Vac
Rated power VDE (DB cos phi=1)
4000 VA
Version | Rated input voltage | Rated output voltage | Rated power VDE (DB cos phi=1) | |
---|---|---|---|---|
UTT1-4-23 | 208 Vac/ 230 Vac/ 380 Vac/ 400 Vac/ 415 Vac/ 440 Vac/ 460 Vac/ 480 Vac/ 500 Vac/ 525 Vac/ 550 Vac/ 575 Vac/ 600 Vac | 2 x 115 Vac | 4000 VA | |
UTT1-6-23 | 208 Vac/ 230 Vac/ 380 Vac/ 400 Vac/ 415 Vac/ 440 Vac/ 460 Vac/ 480 Vac/ 500 Vac/ 525 Vac/ 550 Vac/ 575 Vac/ 600 Vac | 2 x 115 Vac | 6000 VA |
Technical Data for UTT1-4-23
Input | |
---|---|
Rated input voltage | 208 Vac/ 230 Vac/ 380 Vac/ 400 Vac/ 415 Vac/ 440 Vac/ 460 Vac/ 480 Vac/ 500 Vac/ 525 Vac/ 550 Vac/ 575 Vac/ 600 Vac |
Rated frequency | 50 - 60 Hz |
Output | |
---|---|
Rated output voltage | 2 x 115 Vac |
Rated power VDE (DB cos phi=1) | 4000 VA |
Rated power VDE (KB cos phi=0.5) | 11000 VA |
No-load voltage (app. x factor) | 1.03 |
Efficiency | 94.8 % |
Standards | |
---|---|
Classification | Control- and isolating transformer |
Approvals | |
---|---|
Approvals | cURus |
Environment | |
---|---|
Ambient temperature max. | 104.0 °F |
Type of cooling | AN |
Safety and protection | |
---|---|
Type | Open type |
Insulation class | VDE=F, UL=class 155 |
Protection index | IP 00 IPXXB on request |
Safety class (prepared) | I |
Short circuit strength | non-short-circuit proof |
Terminal and mounting | |
---|---|
Fixing method | Base plate |
Fixing screws | M10 |
Terminals Input | Screw clamp, 4 mm² |
Terminals Output | Screw clamp, 10 mm² |
Connection type | Screw-type terminal, 4 mm² |
Measures and weights | |
---|---|
Depth | 7.28 inch |
Height | 13.19 inch |
Width | 9.45 inch |
Weight | 79.37 lbs |
Information for UTT1 series
General Data
- Efficiency up to 96 %
- Rated power 4000 – 6000 VA
- Maximum ambient temperature 104 °F / 40 °C
- Insulation class F
- Rated input voltage 208 - 600 Vac
- Rated output voltage 2 x 115 Vac
- Degree of protection IP 00
Benefits
- Fixed, contact protected screw connection terminals complying with UVV BGV A3
- Universal input voltages 208 to 600 Vac
- Primary side ±5 % taps for voltage adjustment
- Safe galvanic isolation
- Multi-functional mounting brackets with 8 slots
- Very good corrosion protection and low noise due to BLOCK IMPEX vacuum impregnation
- Space saving due to horizontal design
- Integrated crane eyes
- Non-slip terminals
- Patented assembly technology