TT3-A125-4040-0
Isolating transformer TT3 Neo
Version TT3-A125-4040-0
Rated input voltage
3 x 400 Vac
Rated output voltage
3 x 400 Vac
Power
125,000 VA
Version | Rated input voltage | Rated output voltage | Power | |
---|---|---|---|---|
--toBeInserted-- | ||||
TT3-A010-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 10,000 VA | |
TT3-A016-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 16,000 VA | |
TT3-A020-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 20,000 VA | |
TT3-A025-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 25,000 VA | |
TT3-A030-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 30,000 VA | |
TT3-A040-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 40,000 VA | |
TT3-A050-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 50,000 VA | |
TT3-A063-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 63,000 VA | |
TT3-A080-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 80,000 VA | |
TT3-A100-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 100,000 VA | |
TT3-A125-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 125,000 VA | |
TT3-A160-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 160,000 VA | |
TT3-A200-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 200,000 VA | |
TT3-A250-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 250,000 VA | |
TT3-A315-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 315,000 VA | |
TT3-A400-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 400,000 VA | |
TT3-A500-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 500,000 VA | |
TT3-A630-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 630,000 VA | |
TT3C1000-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 1,000,000 VA | |
TT3-A800-4040-0 | 3 x 400 Vac | 3 x 400 Vac | 800,000 VA |
Technical Data for TT3-A125-4040-0
Input | |
---|---|
Rated input voltage | 3 x 400 Vac |
Rated frequency | 50 - 60 Hz |
Output | |
---|---|
Rated output voltage | 3 x 400 Vac |
Power | 125,000 VA |
Output rated current | 3 x 180.4 A |
Short circuit voltage | 4,4 % |
Vector group | Dyn 5 |
Environment | |
---|---|
Ambient temperature max. | 104.0 °F |
Safety and protection | |
---|---|
Insulation class | F |
Protection index | IP 00 |
Type | Open type |
Safety class (prepared) | I |
Short circuit strength | non-short-circuit proof |
Terminal and mounting | |
---|---|
Terminals | Screw-type terminal 70 mm² |
Fixing method | Fixing rail |
Terminals Input | Screw clamp, 70 mm² |
Terminals Output | Screw clamp, 70 mm² |
Connection type | Screw-type terminal, 70 mm² |
Measures and weights | |
---|---|
Width | 29.13 inch |
Height | 31.69 inch |
Depth | 15.75 inch |
Core type | 3UC 594/175 |
Weight | 903.90 lbs |
Information for TT3 Neo series
General Data
- Degree of protection IP 00
- Rated power 10 kVA - 1 MVA
- Insulation class F
- Maximum ambient temperature 104 °F / 40 °C
- Rated output voltage 3 x 400 Vac
- Rated input voltage 3 x 400 Vac
Benefits
- Safe galvanic isolation
- Very good corrosion protection and low noise due to BLOCK IMPEX vacuum impregnation
- Integrated crane eyes
- If needed, voltages up to 1 KV are available
- Very good discharging of thermal losses by means of optimally arranged cooling channels within the coils