TT3-A125-4040-0

Isolating transformer TT3 Neo

Version TT3-A125-4040-0
Rated input voltage 3 x 400 Vac Rated output voltage 3 x 400 Vac Power 125,000 VA
Version Rated input voltage Rated output voltage Power
--toBeInserted--
TT3-A010-4040-0 3 x 400 Vac 3 x 400 Vac 10,000 VA
TT3-A016-4040-0 3 x 400 Vac 3 x 400 Vac 16,000 VA
TT3-A020-4040-0 3 x 400 Vac 3 x 400 Vac 20,000 VA
TT3-A025-4040-0 3 x 400 Vac 3 x 400 Vac 25,000 VA
TT3-A030-4040-0 3 x 400 Vac 3 x 400 Vac 30,000 VA
TT3-A040-4040-0 3 x 400 Vac 3 x 400 Vac 40,000 VA
TT3-A050-4040-0 3 x 400 Vac 3 x 400 Vac 50,000 VA
TT3-A063-4040-0 3 x 400 Vac 3 x 400 Vac 63,000 VA
TT3-A080-4040-0 3 x 400 Vac 3 x 400 Vac 80,000 VA
TT3-A100-4040-0 3 x 400 Vac 3 x 400 Vac 100,000 VA
TT3-A125-4040-0 3 x 400 Vac 3 x 400 Vac 125,000 VA
TT3-A160-4040-0 3 x 400 Vac 3 x 400 Vac 160,000 VA
TT3-A200-4040-0 3 x 400 Vac 3 x 400 Vac 200,000 VA
TT3-A250-4040-0 3 x 400 Vac 3 x 400 Vac 250,000 VA
TT3-A315-4040-0 3 x 400 Vac 3 x 400 Vac 315,000 VA
TT3-A400-4040-0 3 x 400 Vac 3 x 400 Vac 400,000 VA
TT3-A500-4040-0 3 x 400 Vac 3 x 400 Vac 500,000 VA
TT3-A630-4040-0 3 x 400 Vac 3 x 400 Vac 630,000 VA
TT3C1000-4040-0 3 x 400 Vac 3 x 400 Vac 1,000,000 VA
TT3-A800-4040-0 3 x 400 Vac 3 x 400 Vac 800,000 VA
Image of BLOCK Item: TT3-A125-4040-0

Technical Data for TT3-A125-4040-0

Input
Rated input voltage 3 x 400 Vac
Rated frequency 50 - 60 Hz
Output
Rated output voltage 3 x 400 Vac
Power 125,000 VA
Output rated current 3 x 180.4 A
Short circuit voltage 4,4 %
Vector group Dyn 5
Environment
Ambient temperature max. 104.0 °F
Safety and protection
Insulation class F
Protection index IP 00
Type Open type
Safety class (prepared) I
Short circuit strength non-short-circuit proof
Terminal and mounting
Terminals Screw-type terminal 70 mm²
Fixing method Fixing rail
Terminals Input Screw clamp, 70 mm²
Terminals Output Screw clamp, 70 mm²
Connection type Screw-type terminal, 70 mm²
Measures and weights
Width 29.13 inch
Height 31.69 inch
Depth 15.75 inch
Core type 3UC 594/175
Weight 903.90 lbs

Information for TT3 Neo series

General Data
  • Degree of protection IP 00
  • Rated power 10 kVA - 1 MVA
  • Insulation class F
  • Maximum ambient temperature 104 °F / 40 °C
  • Rated output voltage 3 x 400 Vac
  • Rated input voltage 3 x 400 Vac
Benefits
  • Safe galvanic isolation
  • Very good corrosion protection and low noise due to BLOCK IMPEX vacuum impregnation
  • Integrated crane eyes
  • If needed, voltages up to 1 KV are available
  • Very good discharging of thermal losses by means of optimally arranged cooling channels within the coils

Our recommendations for you

BLOCK product: BGE-115
BGE-115
Metal enclosure
Flexible mounting for easy installation, Degree of protection IP 23, For floor mounting, For power 3,000 – 420,000 VA
View accessory