Control- and isolating transformer

TT1 8-44-23

Characteristics

General data

The control transformers of the TT1 series ensure safe galvanic isolation of the primary circuit from the secondary circuit. The unique BLOCK IMPEX vacuum impregnation process provides excellent protection against external influences while reducing noise levels. The transformers stand out with a wide range of mounting options and integrated crane eyelets for transport and installation.

Benefits

 Control and isolating transformer according to EN (IEC) 61558-2-2 and EN (IEC) 61558-2-4

 Patented mounting technology

 Primary side ±5% taps for voltage adjustment

 Fixed, touch-protected screw terminals according to UVV BGV A3

 Space-saving due to upright design

Product (Headline_Detailseite) Control- and isolating transformer
Order number (PF_Teilenummer) TT1 8-44-23
Series (PF_Baureihe) TT1
Power (PF_Leistung_VA_W) 8,000 VA
Input (PF_Trafo_Eingang) 418 V / 440 V / 462 V
Output (PF_Trafo_Ausgang) 2 x 115 V • 34.8 Aac
Phases (PF_Phasen) 1
Frequency range (PF_Frequenzbereich) 50 Hz to 60 Hz
Short-Circuit Losses (PF_Kurzschlussverluste_W) 217 W
No-Load Losses (PF_Leerlaufverluste_W) 107 W
Short-Term Power / instantaneous output (PF_Kurzzeitleistung_VA) 28,000 VA
Short circuit voltage uk (PF_Kurzschlussspannung) 2.7 %
EN Insulation class (PF_EN_Isolierstoffklasse) F (155°C)
UL Insulation class (PF_UL_Isolierstoffklasse) class 155
Duty Cycle (PF_Einschaltdauer) 100 %
Wire material (PF_Leitermaterial) Copper
Efficiency (PF_Wirkungsgrad) 96.1 %
General
Short circuit proof (PF_Kurzschlussfestigkeit_KS_Festigkeit) not short-circuit proof
Switching group (PF_Schaltgruppe) Iii0
Cooling type (PF_Kuehlungsart) AN
Environment
Ambient temperature (PF_Umgebungstemperatur) -20 °C to 40 °C / -4 °F to 104 °F
Max. installation height (PF_max_Aufstellhoehe_m) 2,000 m / 6,562 ft
Protection and Safety
Protection type (PF_Schutzart) IP XX B
Protection class (prepared) (PF_Schutzklasse) I
Overvoltage category (PF_ueberspannungskategorie) III
Degree of contamination (PF_Verschmutzungsgrad) 1
Electrical Connections
Input terminal (PF_Anschluss_Eingang) Screw terminal
Output terminal (PF_Anschluss_Ausgang) Screw terminal
Terminal PE (PF_Anschluss_PE) Screw terminal
Size and Weight
Width (PF_Breite_mm) 280 mm / 11.02 in
Height (PF_Hoehe_mm) 385 mm / 15.16 in
Depth (PF_Tiefe_mm) 215 mm / 8.46 in
Weight (PF_Gewicht_kg) 60 kg / 132.277 lbs
Low Voltage Directive EN 61558-2-2
EN 61558-2-4
Approval cURus - Recognized UL 5085-1/-2; CSA 22.2

This could also be of interest to you

TT1 10-44-23
Control- and isolating transformer • 1ph • 10000 VA • IN: 418-462 Vac • OUT: 2 x 115 Vac
Product details
TT1 6,3-44-23
Control- and isolating transformer • 1ph • 6300 VA • IN: 418-462 Vac • OUT: 2 x 115 Vac
Product details
UTT1-6-23
Control- and isolating transformer • 1ph • 6000 VA • IN: 208-600 Vac • OUT:  115-230 Vac
Product details
TT1 5-44-23
Control- and isolating transformer • 1ph • 5000 VA • IN: 418-462 Vac • OUT: 2 x 115 Vac
Product details
TT1 4-44-23
Control- and isolating transformer • 1ph • 4000 VA • IN: 418-462 Vac • OUT: 2 x 115 Vac
Product details
UTT1-4-23
Control- and isolating transformer • 1ph • 4000 VA • IN: 208-600 Vac • OUT:  115-230 Vac
Product details