STE 100/23/24

Control- and safety isolating transformer

Version STE 100/23/24
Rated input voltage 230 Vac Rated output voltage 24 Vac Rated power VDE (DB cos phi=1) 100 VA
Version Rated input voltage Rated output voltage Rated power VDE (DB cos phi=1)
STE 63/23/24 230 Vac 24 Vac 63 VA
STE 63/4/24 400 Vac 24 Vac 63 VA
STE 63/4/23 400 Vac 230 Vac 63 VA
STE 100/23/24 230 Vac 24 Vac 100 VA
STE 100/4/23 400 Vac 230 Vac 100 VA
STE 160/23/24 230 Vac 24 Vac 160 VA
STE 160/4/23 400 Vac 230 Vac 160 VA
STE 250/23/24 230 Vac 24 Vac 250 VA
STE 250/4/24 400 Vac 24 Vac 250 VA
STE 250/4/23 400 Vac 230 Vac 250 VA
STE 320/23/24 230 Vac 24 Vac 320 VA
STE 320/4/23 400 Vac 230 Vac 320 VA
STE 400/23/24 230 Vac 24 Vac 400 VA
STE 400/4/23 400 Vac 230 Vac 400 VA
STE 500/23/24 230 Vac 24 Vac 500 VA
STE 500/4/24 400 Vac 24 Vac 500 VA
STE 500/4/23 400 Vac 230 Vac 500 VA
STE 630/4/23 400 Vac 230 Vac 630 VA
STE 800/4/23 400 Vac 230 Vac 800 VA
STE 1000/4/23 400 Vac 230 Vac 1,000 VA
STE 1600/4/23 400 Vac 230 Vac 1,600 VA
STE 2000/4/23 400 Vac 230 Vac 2.000 VA
STE 2500/4/23 400 Vac 230 Vac 2.500 VA
Image of BLOCK Item: STE 100/23/24
Technical files Data sheet CAD/CAE data 3D-CAD-Model (STEP) ePlan Makro

Technical Data for STE 100/23/24

Input
Rated input voltage 230 Vac
Tappings Input ±5 %
Rated frequency 50 - 60 Hz
Output
Rated output voltage 24 Vac
Rated power VDE (DB cos phi=1) 100 VA
Rated power VDE (KB cos phi=0.5) 310 VA
No-load voltage (app. x factor) 1.07
Efficiency 87 %
Approvals
Approvals cURus
Environment
Ambient temperature max. 104.0 °F
Type of cooling self-cooling
Safety and protection
Type Open type
Insulation class VDE=B, UL=class 130
Protection index IP 00
Safety class (prepared) I
Short circuit strength non-short-circuit proof
PRI Fusing recommendation by circuit breaker with tripping characteristic type 20 x Irated related to set)
Setting range 0.40 - 0.63 A
Setting value 0.5 A
Terminal and mounting
Fixing method Dual purpose base plate also for installation on mounting rails
Fixing screws M4
Terminals Input push-in terminals, 4 mm²
Terminals Output push-in terminals, 4 mm²
Connection type Tab connector, 6.3 x 0.8 mm
Measures and weights
Width 3.31 inch
Height 3.86 inch
Depth 4.41 inch
Weight 4.41 lbs

Information for STE series

General Data
  • Rated power 63 - 2,500 VA
  • Degree of protection IP 00
  • Efficiency up to 95 %
  • Maximum ambient temperature 104 °F / 40 °C
  • Insulation class B
  • Rated output voltage 24 - 230 Vac
  • Rated input voltage 230 - 400 Vac
Benefits
  • DIN rail clamp included up to 250 VA
  • Very good corrosion protection and low noise due to BLOCK IMPEX vacuum impregnation
  • Reduced inrush current
  • High power density due to a compact construction design
  • Primary side ±5 % taps for voltage adjustment
  • Simple mounting due to robust metal footplate with oval slots
  • Fast installation because of the use of push-in terminals
  • Contact protected screw connection terminals complying with UVV BGV A3

Our recommendations for you

BLOCK product: CT-010-048-24-1
CT-010-048-24-1
Control power transformer
Base plate, PRI 2 x 240 Vac, 600 Vac, SEC 24 Vac, 120 Vac, 50 – 2,500 VA
View accessory
BLOCK product: BGUK 1
BGUK 1
Metal enclosures
Integrated rail system for the installation of different product sizes, Degree of protection IP 20 - IP 23, For wall and floor mounting, For Power 63 - 25,000 VA
View accessory
BLOCK product: ACT 100
ACT 100
Safety isolating transformer
Panel installation on mounting rails, PRI 230 Vac, SEC 24 Vac, 10 - 100 VA
View accessory
BLOCK product: CT-010-048-24-0
CT-010-048-24-0
Control power transformer
Base plate, PRI 2 x 240 Vac, 600 Vac, SEC 24 Vac, 120 Vac, 50 – 2,500 VA
View accessory
BLOCK product: CT-010-048-24-2
CT-010-048-24-2
Control power transformer
Base plate, PRI 2 x 240 Vac, 600 Vac, SEC 24 Vac, 120 Vac, 50 – 2,500 VA