SFB 400/180

Sine filter SFB

Version SFB 400/180
Rated voltage max. 3 x 520 Vac Rated current 180 A for motor rated output approx. 120.69 HP
Version Rated voltage Rated current for motor rated output approx.
SFB 400/4 max. 3 x 520 Vac 4 A 2.01 HP
SFB 400/10 max. 3 x 520 Vac 10 A 5.36 HP
SFB 400/16,5 max. 3 x 520 Vac 16.5 A 10.06 HP
SFB 400/23,5 max. 3 x 520 Vac 23.5 A 14.75 HP
SFB 400/32 max. 3 x 520 Vac 32 A 20.12 HP
SFB 400/37 max. 3 x 520 Vac 37 A 24.81 HP
SFB 400/48 max. 3 x 520 Vac 48 A 29.50 HP
SFB 400/115 max. 3 x 520 Vac 115 A 73.76 HP
SFB 400/150 max. 3 x 520 Vac 150 A 100.58 HP
SFB 400/180 max. 3 x 520 Vac 180 A 120.69 HP
SFB 400/250 max. 3 x 520 Vac 250 A 177.01 HP
SFB 400/440 max. 3 x 520 Vac 440 A 335.25 HP
SFB 400/480 max. 3 x 520 Vac 480 A 348.66 HP
SFB-N 400/61 max. 3 x 520 Vac 61 A 40.23 HP
SFB-N 400/72 max. 3 x 520 Vac 72 A 49.62 HP
SFB-N 400/90 max. 3 x 520 Vac 90 A 60.34 HP
Image of BLOCK Item: SFB 400/180

Technical Data for SFB 400/180

Operating data
Rated voltage max. 3 x 520 Vac
Voltage range 0 - 520 Vac
Voltage drop 7.5 % @ 400 Vac
Rated current 180 A
for motor rated output approx. 120.69 HP
Rated frequency 0 - 60 Hz
Switching frequency 4 - 8 kHz
Approvals
Approvals cURus
Environment
Ambient temperature max. 104.0 °F
Safety and protection
Type Open type
Insulation class H
Protection index IP 00
Safety class (prepared) I
Test voltage 3000 Vac, 50 Hz
Terminal and mounting
Terminals phase Screw clamp, 150 mm²
Connection type Bolt, M8
Fixing method Fixing rail
Fixing screws M10
Mounting position only for vertical mounting
Measures and weights
Depth 14.17 inch
Height 17.52 inch
Width 14.37 inch
Weight 165.35 lbs

Information for SFB series

General Data
  • For switching frequencies of 4 to 8 kHz
  • Ambient temperature 14 °F / -10 °C to +104 °F / +40 °C
  • Insulation class H
  • Rated frequency from 0 to 150 Hz
  • For motor rated output 2 to 348 HP
  • Rated current 4 to 480 A
  • Rated voltage 3 x 400 Vac
  • Degree of protection IP 00
Benefits
  • Prevention of overvoltages on the motor
  • Very good corrosion protection and low noise due to vacuum impregnation
  • Long cable lengths possible
  • Reduction in motor noise
  • Reduction in line-borne and field-borne emitted interference
  • Reduction in motor losses

Our recommendations for you

BLOCK product: HLD 110-500/180
HLD 110-500/180
Radio interference suppression filter, three-phase
3 x 520 Vac, 3 x 8 – 3 x 250 A, Leakage current 20.00 to 37.00 mA, For enhanced EMI suppression
View accessory
BLOCK product: MR3-AD200-483-0
MR3-AD200-483-0
Motor reactor
3 x 480 Vac, 1 – 400 A, For motor rated output 0.5 to 300 HP
View accessory
BLOCK product: SF4-CE110-500-0
SF4-CE110-500-0
All-pole sine filter
max. 3 x 500 Vac, 6 – 165 A, For motor rated output 3 to 120.69 HP, For switching frequencies ≥ 4 kHz
View accessory