RKD 1600/2x115
Isolating transformer
Version RKD 1600/2x115
Rated input voltage
2 x 115 Vac
Rated output voltage
2 x 115 Vac
Power
1,600 VA
Version | Rated input voltage | Rated output voltage | Power | |
---|---|---|---|---|
RKD 15/2x6 | 2 x 115 Vac | 2 x 6 Vac | 15 VA | |
RKD 15/2x9 | 2 x 115 Vac | 2 x 9 Vac | 15 VA | |
RKD 15/2x12 | 2 x 115 Vac | 2 x 12 Vac | 15 VA | |
RKD 15/2x15 | 2 x 115 Vac | 2 x 15 Vac | 15 VA | |
RKD 15/2x18 | 2 x 115 Vac | 2 x 18 Vac | 15 VA | |
RKD 20/2x12 | 2 x 115 Vac | 2 x 12 Vac | 20 VA | |
RKD 20/2x15 | 2 x 115 Vac | 2 x 15 Vac | 20 VA | |
RKD 20/2x18 | 2 x 115 Vac | 2 x 18 Vac | 20 VA | |
RKD 20/2x24 | 2 x 115 Vac | 2 x 24 Vac | 20 VA | |
RKD 30/2x6 | 2 x 115 Vac | 2 x 6 Vac | 30 VA | |
RKD 30/2x9 | 2 x 115 Vac | 2 x 9 Vac | 30 VA | |
RKD 30/2x12 | 2 x 115 Vac | 2 x 12 Vac | 30 VA | |
RKD 30/2x15 | 2 x 115 Vac | 2 x 15 Vac | 30 VA | |
RKD 30/2x18 | 2 x 115 Vac | 2 x 18 Vac | 30 VA | |
RKD 30/2x24 | 2 x 115 Vac | 2 x 24 Vac | 30 VA | |
RKD 40/2x6 | 2 x 115 Vac | 2 x 6 Vac | 40 VA | |
RKD 40/2x9 | 2 x 115 Vac | 2 x 9 Vac | 40 VA | |
RKD 40/2x12 | 2 x 115 Vac | 2 x 12 Vac | 40 VA | |
RKD 40/2x15 | 2 x 115 Vac | 2 x 15 Vac | 40 VA | |
RKD 40/2x18 | 2 x 115 Vac | 2 x 18 Vac | 40 VA | |
RKD 40/2x24 | 2 x 115 Vac | 2 x 24 Vac | 40 VA | |
RKD 50/2x12 | 2 x 115 Vac | 2 x 12 Vac | 50 VA | |
RKD 50/2x15 | 2 x 115 Vac | 2 x 15 Vac | 50 VA | |
RKD 50/2x18 | 2 x 115 Vac | 2 x 18 Vac | 50 VA | |
RKD 50/2x24 | 2 x 115 Vac | 2 x 24 Vac | 50 VA | |
RKD 60/2x6 | 2 x 115 Vac | 2 x 6 Vac | 60 VA | |
RKD 60/2x9 | 2 x 115 Vac | 2 x 9 Vac | 60 VA | |
RKD 60/2x12 | 2 x 115 Vac | 2 x 12 Vac | 60 VA | |
RKD 60/2x15 | 2 x 115 Vac | 2 x 15 Vac | 60 VA | |
RKD 60/2x18 | 2 x 115 Vac | 2 x 18 Vac | 60 VA | |
RKD 60/2x24 | 2 x 115 Vac | 2 x 24 Vac | 60 VA | |
RKD 60/2x30 | 2 x 115 Vac | 2 x 30 Vac | 60 VA | |
RKD 80/2x12 | 2 x 115 Vac | 2 x 12 Vac | 80 VA | |
RKD 80/2x15 | 2 x 115 Vac | 2 x 15 Vac | 80 VA | |
RKD 80/2x18 | 2 x 115 Vac | 2 x 18 Vac | 80 VA | |
RKD 80/2x24 | 2 x 115 Vac | 2 x 24 Vac | 80 VA | |
RKD 100/2x9 | 2 x 115 Vac | 2 x 9 Vac | 100 VA | |
RKD 100/2x12 | 2 x 115 Vac | 2 x 12 Vac | 100 VA | |
RKD 100/2x15 | 2 x 115 Vac | 2 x 15 Vac | 100 VA | |
RKD 100/2x18 | 2 x 115 Vac | 2 x 18 Vac | 100 VA | |
RKD 100/2x24 | 2 x 115 Vac | 2 x 24 Vac | 100 VA | |
RKD 100/2x30 | 2 x 115 Vac | 2 x 30 Vac | 100 VA | |
RKD 120/2x9 | 2 x 115 Vac | 2 x 9 Vac | 120 VA | |
RKD 120/2x12 | 2 x 115 Vac | 2 x 12 Vac | 120 VA | |
RKD 120/2x15 | 2 x 115 Vac | 2 x 15 Vac | 120 VA | |
RKD 120/2x18 | 2 x 115 Vac | 2 x 18 Vac | 120 VA | |
RKD 120/2x24 | 2 x 115 Vac | 2 x 24 Vac | 120 VA | |
RKD 120/2x30 | 2 x 115 Vac | 2 x 30 Vac | 120 VA | |
RKD 160/2x12 | 2 x 115 Vac | 2 x 12 Vac | 160 VA | |
RKD 160/2x15 | 2 x 115 Vac | 2 x 15 Vac | 160 VA | |
RKD 160/2x18 | 2 x 115 Vac | 2 x 18 Vac | 160 VA | |
RKD 160/2x24 | 2 x 115 Vac | 2 x 24 Vac | 160 VA | |
RKD 160/2x30 | 2 x 115 Vac | 2 x 30 Vac | 160 VA | |
RKD 160/2x35 | 2 x 115 Vac | 2 x 35 Vac | 160 VA | |
RKD 200/2x12 | 2 x 115 Vac | 2 x 12 Vac | 200 VA | |
RKD 200/2x15 | 2 x 115 Vac | 2 x 15 Vac | 200 VA | |
RKD 200/2x18 | 2 x 115 Vac | 2 x 18 Vac | 200 VA | |
RKD 200/2x24 | 2 x 115 Vac | 2 x 24 Vac | 200 VA | |
RKD 225/2x12 | 2 x 115 Vac | 2 x 12 Vac | 225 VA | |
RKD 225/2x15 | 2 x 115 Vac | 2 x 15 Vac | 225 VA | |
RKD 225/2x18 | 2 x 115 Vac | 2 x 18 Vac | 225 VA | |
RKD 225/2x24 | 2 x 115 Vac | 2 x 24 Vac | 225 VA | |
RKD 225/2x30 | 2 x 115 Vac | 2 x 30 Vac | 225 VA | |
RKD 250/2x12 | 2 x 115 Vac | 2 x 12 Vac | 250 VA | |
RKD 250/2x18 | 2 x 115 Vac | 2 x 18 Vac | 250 VA | |
RKD 250/2x24 | 2 x 115 Vac | 2 x 24 Vac | 250 VA | |
RKD 250/2x30 | 2 x 115 Vac | 2 x 30 Vac | 250 VA | |
RKD 300/2x12 | 2 x 115 Vac | 2 x 12 Vac | 300 VA | |
RKD 300/2x18 | 2 x 115 Vac | 2 x 18 Vac | 300 VA | |
RKD 300/2x24 | 2 x 115 Vac | 2 x 24 Vac | 300 VA | |
RKD 330/2x18 | 2 x 115 Vac | 2 x 18 Vac | 330 VA | |
RKD 400/2x18 | 2 x 115 Vac | 2 x 18 Vac | 400 VA | |
RKD 400/2x24 | 2 x 115 Vac | 2 x 24 Vac | 400 VA | |
RKD 400/2x30 | 2 x 115 Vac | 2 x 30 Vac | 400 VA | |
RKD 500/2x24 | 2 x 115 Vac | 2 x 24 Vac | 500 VA | |
RKD 500/2x30 | 2 x 115 Vac | 2 x 30 Vac | 500 VA | |
RKD 500/2x35 | 2 x 115 Vac | 2 x 35 Vac | 500 VA | |
RKD 625/2x30 | 2 x 115 Vac | 2 x 30 Vac | 625 VA | |
RKD 625/2x115 | 2 x 115 Vac | 2 x 115 Vac | 625 VA | |
RKD 800/2x40 | 2 x 115 Vac | 2 x 40 Vac | 800 VA | |
RKD 800/2x115 | 2 x 115 Vac | 2 x 115 Vac | 800 VA | |
RKD 1000/2x50 | 2 x 115 Vac | 2 x 50 Vac | 1,000 VA | |
RKD 1000/2x115 | 2 x 115 Vac | 2 x 115 Vac | 1,000 VA | |
RKD 1200/2x115 | 2 x 115 Vac | 2 x 115 Vac | 1,200 VA | |
RKD 1600/2x115 | 2 x 115 Vac | 2 x 115 Vac | 1,600 VA | |
RKD 2000/2x115 | 2 x 115 Vac | 2 x 115 Vac | 2,000 VA | |
RKD 3000/2x115 | 2 x 115 Vac | 2 x 115 Vac | 3,000 VA |
Technical Data for RKD 1600/2x115
Input | |
---|---|
Rated input voltage | 2 x 115 Vac |
Rated frequency | 50 - 60 Hz |
Output | |
---|---|
Rated output voltage | 2 x 115 Vac |
Power | 1,600 VA |
No-load voltage (app. x factor) | 1.02 |
No-load loss (typ.) | 9.6 W |
Efficiency | 97 % |
Secondary circuit | 2 |
Standards | |
---|---|
Classification | Isolating transformer |
Approvals | |
---|---|
Approvals | cURus |
Environment | |
---|---|
Ambient temperature max. | 104.0 °F |
Safety and protection | |
---|---|
Type | Open type |
Insulation class | VDE=B, UL=class 105 |
Protection index | IP 00 |
Safety class (prepared) | II |
Short circuit strength | non-short-circuit proof |
Test voltage | 4,000 Vac, 50 Hz |
Terminal and mounting | |
---|---|
Fixing method | Remaining hole casting, with integrated mounting holes |
Terminals | Connecting leads, 200 mm |
Measures and weights | |
---|---|
Major diameter Ø | 7.95 inch |
Outside diameter in the area of the wire lead Ø | 8.07 inch |
Height without mounting | 4.13 inch |
Weight | 28.00 lbs |
Information for RKD series
General Data
- Power 15 - 3,000 VA
- Efficiency up to 98 %
- Maximum ambient temperature 104 °F / 40 °C
- Insulation class B
- Degree of protection IP 00
- Rated output voltage 2 x 6 - 2 x 115 Vac
- Rated input voltage 2 x 115 Vac
Benefits
- Low weight
- Outstanding temperature behavior due to low magnetic leakage field
- Minimum size at high power
- Minimal no-load losses
- Dual input and dual output voltage for series or parallel connection
- Very low noise field