NKE 2/25,50
Line reactor NKE 230 / 400
Version NKE 2/25,50
Rated voltage
max. 400 Vac
Rated current
2 A
Version | Rated voltage | Rated current | ||
---|---|---|---|---|
NKE 2/14,65 | max. 230 Vac | 2 A | ||
NKE 2/25,50 | max. 400 Vac | 2 A | ||
NKE 4/7,33 | max. 230 Vac | 4 A | ||
NKE 4/12,75 | max. 400 Vac | 4 A | ||
NKE 6/4,88 | max. 230 Vac | 6 A | ||
NKE 6/8,50 | max. 400 Vac | 6 A | ||
NKE 10/2,93 | max. 230 Vac | 10 A | ||
NKE 10/5,10 | max. 400 Vac | 10 A | ||
NKE 16/1,83 | max. 230 Vac | 16 A | ||
NKE 16/3,19 | max. 400 Vac | 16 A | ||
NKE 20/1,47 | max. 230 Vac | 20 A | ||
NKE 20/2,55 | max. 400 Vac | 20 A | ||
NKE 25/1,17 | max. 230 Vac | 25 A | ||
NKE 25/2,04 | max. 400 Vac | 25 A | ||
NKE 35/0,84 | max. 230 Vac | 35 A | ||
NKE 35/1,46 | max. 400 Vac | 35 A | ||
NKE 40/0,73 | max. 230 Vac | 40 A | ||
NKE 40/1,28 | max. 400 Vac | 40 A | ||
NKE 50/0,59 | max. 230 Vac | 50 A | ||
NKE 50/1,02 | max. 400 Vac | 50 A | ||
NKE 63/0,49 | max. 230 Vac | 63 A | ||
NKE 63/0,81 | max. 400 Vac | 63 A | ||
NKE 100/0,29 | max. 230 Vac | 100 A | ||
NKE 125/0,23 | max. 230 Vac | 125 A |
DOWNLOADS
Technical files
Data sheet
Approvals / Manufacturer's declaration
EU-Declaration of Conformity
Technical Data for NKE 2/25,50
Operating data | |
---|---|
Rated voltage | max. 400 Vac |
Voltage drop | 9,2 Vac |
Rated current | 2 A |
Rated frequency | 50 - 60 Hz |
Inductance | 25.5 mH |
Inductance deviation | ±10% |
Approvals | |
---|---|
Approvals | cURus |
Environment | |
---|---|
Ambient temperature | 14 °F to +104 °F |
Type of cooling | AN |
Safety and protection | |
---|---|
Insulation class | B |
Protection index | IP 00 |
Safety class (prepared) | I |
Type | Open type |
Test voltage | 2500 Vac |
Terminal and mounting | |
---|---|
Terminals phase | Screw clamp, 2.5 mm² |
Connection type | Tab connector, 6.3 x 0.8 mm |
Fixing method | Base plate |
Fixing screws | M3 |
Measures and weights | |
---|---|
Depth | 2.36 inch |
Height | 3.07 inch |
Width | 2.60 inch |
Weight | 1.10 lbs |
Information for NKE 230 / 400 series
General Data
- Insulation class B
- Inductance 1.170 to 12.750 mH
- Degree of protection IP 00
- Ambient temperature 14 °F / -10 °C to +104 °F / +40 °C
- Rated voltage 230 or 400 Vac
- Rated current 2 - 63 A
Benefits
- Use as line reactor, commutating reactor or PFC reactor
- Peak current limitation
- Bridging voltage dips
- Very good corrosion protection and low noise due to vacuum impregnation
- Low ripple
- Increases the service life of equipment
- Starting current limitation
- Power harmonic damping