Line reactor, three-phase

LR3-AE125-483-0

Characteristics

Benefits

 Use as line reactor, commutating reactor or PFC reactor

 Ensuring the short-circuit voltage of 4 % to the mains

 Power harmonic damping

 Starting current limitation

 Increases the service life of consumers

 Low ripple

 Bridging voltage dips

 Peak current limitation

 Very good corrosion protection and low noise due to vacuum impregnation

 AD and AE types with UL approval

Product Search
Product (Headline_Detailseite) Line reactor, three-phase
Order number (PF_Teilenummer) LR3-AE125-483-0
Series (PF_Baureihe) LR3-A
Inductance (PF_Drossel_Phasen_Induktivitaet) 3x 0.18 mH
Rated current (PF_Drossel_Phasen_Strom) 3x 125 Aac
Linear current (PF_Drossel_Phasen_Linearitaetsstrom) 3x 187.5 Aac
Rated voltage range (PF_Bemessungsspannungsbereich) 0 V to 690 V
Rated voltage (PF_Bemessungsspannung) 480 V
Phases (PF_Phasen) 3
Frequency range (PF_Frequenzbereich) 50 Hz to 60 Hz
Short circuit voltage (PF_Drossel_Kurzschlussspannung) 3% @ 480 V
Motor or converter power (PF_Motor_bzw_Umrichterleistung) 75 kW / 100.58 HP
EN Insulation class (PF_EN_Isolierstoffklasse) H (180°C)
UL Insulation class (PF_UL_Isolierstoffklasse) class 180
Duty Cycle (PF_Einschaltdauer) 100 %
Power loss (PF_Verlustleistung_W) 260.00 W
Wire material (PF_Leitermaterial) Aluminum
General
Duty Cycle (PF_Einschaltdauer) 100 %
Cooling type (PF_Kuehlungsart) AN
Switching group (PF_Schaltgruppe) III0
Environment
Ambient temperature (PF_Umgebungstemperatur) -10 °C to 40 °C / 14 °F to 104 °F
Max. installation height (PF_max_Aufstellhoehe_m) 186 m / 610 ft
Protection and Safety
Protection type (PF_Schutzart) IP00
Protection class (prepared) (PF_Schutzklasse) I
Degree of contamination (PF_Verschmutzungsgrad) 2
Electrical Connections
Input terminal (PF_Anschluss_Eingang) Bolt connection
Output terminal (PF_Anschluss_Ausgang) Bolt connection
Terminal PE (PF_Anschluss_PE) Bolt connection
Size and Weight
Width (PF_Breite_mm) 400 mm / 15.75 in
Height (PF_Hoehe_mm) 186.5 mm / 7.34 in
Depth (PF_Tiefe_mm) 180 mm / 7.09 in
Weight (PF_Gewicht_kg) 16.8 kg / 37.038 lbs
Low Voltage Directive EN 61558-2-20
RoHS compliant EN IEC 63000
Approval cURus - Recognized UL 508; CSA 22.2
Image of BLOCK Item: COV 425x185x108

COV 425x185x108

Cover set

This could also be of interest to you

NKE 40/1,28
Line reactor • 1ph • 0-400 Vac • 40 A • 50-60 Hz • uk:4%@400 V • 1,28 mH
Product details
NKE 6/4,88
Line reactor • 1ph • 0-230 Vac • 6 A • 50-60 Hz • uk:4%@230 V • 4,88 mH
Product details
MDB 400/61
Motor reactor • 3ph • 0-690 Vac • 61 A • 0-120 Hz • P:30 kW • 0,1 mH
Product details
LR3 40-4/20
Line reactor • 3ph • 0-690 Vac • 20 A • 50-60 Hz • uk:4%@400 V • 1,47 mH
Product details
LR3 40-4/4
Line reactor • 3ph • 0-690 Vac • 4 A • 50-60 Hz • uk:4%@400 V • 7,35 mH
Product details
LR3 40-4/40
Line reactor • 3ph • 0-690 Vac • 40 A • 50-60 Hz • uk:4%@400 V • 0,73 mH
Product details