LR3 40-5/25

Line reactor LR3 400

Version LR3 40-5/25
Rated voltage 3 x 400 Vac Rated current 3 x 25 A Short circuit voltage uK 5 % @ 400 Vac
Version Rated voltage Rated current Short circuit voltage uK
LR3 40-3/2 3 x 400 Vac 3 x 2 A 3 % @ 400 Vac
LR3 40-4/2 3 x 400 Vac 3 x 2 A 4 % @ 400 Vac
LR3 40-5/2 3 x 400 Vac 3 x 2 A 5 % @ 400 Vac
LR3 40-3/4 3 x 400 Vac 3 x 4 A 3 % @ 400 Vac
LR3 40-4/4 3 x 400 Vac 3 x 4 A 4 % @ 400 Vac
LR3 40-5/4 3 x 400 Vac 3 x 4 A 5 % @ 400 Vac
LR3 40-3/6 3 x 400 Vac 3 x 6 A 3 % @ 400 Vac
LR3 40-4/6 3 x 400 Vac 3 x 6 A 4 % @ 400 Vac
LR3 40-5/6 3 x 400 Vac 3 x 6 A 5 % @ 400 Vac
LR3 40-3/8 3 x 400 Vac 3 x 8 A 3 % @ 400 Vac
LR3 40-4/8 3 x 400 Vac 3 x 8 A 4 % @ 400 Vac
LR3 40-5/8 3 x 400 Vac 3 x 8 A 5 % @ 400 Vac
LR3 40-3/10 3 x 400 Vac 3 x 10 A 3 % @ 400 Vac
LR3 40-4/10 3 x 400 Vac 3 x 10 A 4 % @ 400 Vac
LR3 40-5/10 3 x 400 Vac 3 x 10 A 5 % @ 400 Vac
LR3 40-3/16 3 x 400 Vac 3 x 16 A 3 % @ 400 Vac
LR3 40-4/16 3 x 400 Vac 3 x 16 A 4 % @ 400 Vac
LR3 40-5/16 3 x 400 Vac 3 x 16 A 5 % @ 400 Vac
LR3 40-3/20 3 x 400 Vac 3 x 20 A 3 % @ 400 Vac
LR3 40-4/20 3 x 400 Vac 3 x 20 A 4 % @ 400 Vac
LR3 40-5/20 3 x 400 Vac 3 x 20 A 5 % @ 400 Vac
LR3 40-3/25 3 x 400 Vac 3 x 25 A 3 % @ 400 Vac
LR3 40-4/25 3 x 400 Vac 3 x 25 A 4 % @ 400 Vac
LR3 40-5/25 3 x 400 Vac 3 x 25 A 5 % @ 400 Vac
LR3 40-3/30 3 x 400 Vac 3 x 30 A 3 % @ 400 Vac
LR3 40-4/30 3 x 400 Vac 3 x 30 A 4 % @ 400 Vac
LR3 40-5/30 3 x 400 Vac 3 x 30 A 5 % @ 400 Vac
LR3 40-3/35 3 x 400 Vac 3 x 35 A 3 % @ 400 Vac
LR3 40-4/35 3 x 400 Vac 3 x 35 A 4 % @ 400 Vac
LR3 40-5/35 3 x 400 Vac 3 x 35 A 5 % @ 400 Vac
LR3 40-3/40 3 x 400 Vac 3 x 40 A 3 % @ 400 Vac
LR3 40-4/40 3 x 400 Vac 3 x 40 A 4 % @ 400 Vac
LR3 40-5/40 3 x 400 Vac 3 x 40 A 5 % @ 400 Vac
LR3 40-3/45 3 x 400 Vac 3 x 45 A 3 % @ 400 Vac
LR3 40-4/45 3 x 400 Vac 3 x 45 A 4 % @ 400 Vac
LR3 40-5/45 3 x 400 Vac 3 x 45 A 5 % @ 400 Vac
LR3 40-3/50 3 x 400 Vac 3 x 50 A 3 % @ 400 Vac
LR3 40-4/50 3 x 400 Vac 3 x 50 A 4 % @ 400 Vac
LR3 40-5/50 3 x 400 Vac 3 x 50 A 5 % @ 400 Vac
LR3 40-3/63 3 x 400 Vac 3 x 63 A 3 % @ 400 Vac
LR3 40-4/63 3 x 400 Vac 3 x 63 A 4 % @ 400 Vac
LR3 40-5/63 3 x 400 Vac 3 x 63 A 5 % @ 400 Vac
LR3 40-3/70 3 x 400 Vac 3 x 70 A 3 % @ 400 Vac
LR3 40-4/70 3 x 400 Vac 3 x 70 A 4 % @ 400 Vac
LR3 40-5/70 3 x 400 Vac 3 x 70 A 5 % @ 400 Vac
LR3 40-3/80 3 x 400 Vac 3 x 80 A 3 % @ 400 Vac
LR3 40-4/80 3 x 400 Vac 3 x 80 A 4 % @ 400 Vac
LR3 40-5/80 3 x 400 Vac 3 x 80 A 5 % @ 400 Vac
LR3 40-3/90 3 x 400 Vac 3 x 90 A 3 % @ 400 Vac
LR3 40-4/90 3 x 400 Vac 3 x 90 A 4 % @ 400 Vac
LR3 40-5/90 3 x 400 Vac 3 x 90 A 5 % @ 400 Vac
LR3 40-3/100 3 x 400 Vac 3 x 100 A 3 % @ 400 Vac
LR3 40-4/100 3 x 400 Vac 3 x 100 A 4 % @ 400 Vac
LR3 40-5/100 3 x 400 Vac 3 x 100 A 5 % @ 400 Vac
LR3 40-3/115 3 x 400 Vac 3 x 115 A 3 % @ 400 Vac
LR3 40-4/115 3 x 400 Vac 3 x 115 A 4 % @ 400 Vac
LR3 40-5/115 3 x 400 Vac 3 x 115 A 5 % @ 400 Vac
LR3 40-3/125 3 x 400 Vac 3 x 125 A 3 % @ 400 Vac
LR3 40-4/125 3 x 400 Vac 3 x 125 A 4 % @ 400 Vac
LR3 40-5/125 3 x 400 Vac 3 x 125 A 5 % @ 400 Vac
LR3 40-3/160 3 x 400 Vac 3 x 160 A 3 % @ 400 Vac
LR3 40-4/160 3 x 400 Vac 3 x 160 A 4 % @ 400 Vac
LR3 40-5/160 3 x 400 Vac 3 x 160 A 5 % @ 400 Vac
LR3 40-3/180 3 x 400 Vac 3 x 180 A 3 % @ 400 Vac
LR3 40-4/180 3 x 400 Vac 3 x 180 A 4 % @ 400 Vac
LR3 40-5/180 3 x 400 Vac 3 x 180 A 5 % @ 400 Vac
LR3 40-3/200 3 x 400 Vac 3 x 200 A 3 % @ 400 Vac
LR3 40-4/200 3 x 400 Vac 3 x 200 A 4 % @ 400 Vac
LR3 40-5/200 3 x 400 Vac 3 x 200 A 5 % @ 400 Vac
LR3 40-3/250 3 x 400 Vac 3 x 250 A 3 % @ 400 Vac
LR3 40-4/250 3 x 400 Vac 3 x 250 A 4 % @ 400 Vac
LR3 40-5/250 3 x 400 Vac 3 x 250 A 5 % @ 400 Vac
LR3 40-3/300 3 x 400 Vac 3 x 300 A 3 % @ 400 Vac
LR3 40-4/300 3 x 400 Vac 3 x 300 A 4 % @ 400 Vac
LR3 40-5/300 3 x 400 Vac 3 x 300 A 5 % @ 400 Vac
LR3 40-3/400 3 x 400 Vac 3 x 400 A 3 % @ 400 Vac
LR3 40-4/400 3 x 400 Vac 3 x 400 A 4 % @ 400 Vac
LR3 40-5/400 3 x 400 Vac 3 x 400 A 5 % @ 400 Vac
LR3 40-3/500 3 x 400 Vac 3 x 500 A 3 % @ 400 Vac
LR3 40-4/500 3 x 400 Vac 3 x 500 A 4 % @ 400 Vac
LR3 40-5/500 3 x 400 Vac 3 x 500 A 5 % @ 400 Vac
LR3 40-3/630 3 x 400 Vac 3 x 630 A 3 % @ 400 Vac
LR3 40-4/630 3 x 400 Vac 3 x 630 A 4 % @ 400 Vac
LR3 40-5/630 3 x 400 Vac 3 x 630 A 5 % @ 400 Vac
LR3 40-3/710 3 x 400 Vac 3 x 710 A 3 % @ 400 Vac
LR3 40-4/710 3 x 400 Vac 3 x 710 A 4 % @ 400 Vac
LR3 40-5/710 3 x 400 Vac 3 x 710 A 5 % @ 400 Vac
LR3 40-3/800 3 x 400 Vac 3 x 800 A 3 % @ 400 Vac
LR3 40-4/800 3 x 400 Vac 3 x 800 A 4 % @ 400 Vac
LR3 40-5/800 3 x 400 Vac 3 x 800 A 5 % @ 400 Vac
LR3 40-3/1000 3 x 400 Vac 3 x 1000 A 3 % @ 400 Vac
LR3 40-4/1000 3 x 400 Vac 3 x 1000 A 4 % @ 400 Vac
LR3 40-5/1000 3 x 400 Vac 3 x 1000 A 5 % @ 400 Vac
LR3 40-3/1200 3 x 400 Vac 3 x 1200 A 3 % @ 400 Vac
LR3 40-4/1200 3 x 400 Vac 3 x 1200 A 4 % @ 400 Vac
LR3 40-5/1200 3 x 400 Vac 3 x 1200 A 5 % @ 400 Vac
LR3 40-3/1400 3 x 400 Vac 3 x 1400 A 3 % @ 400 Vac
LR3 40-4/1400 3 x 400 Vac 3 x 1400 A 4 % @ 400 Vac
LR3 40-5/1400 3 x 400 Vac 3 x 1400 A 5 % @ 400 Vac
LR3 40-3/1600 3 x 400 Vac 3 x 1600 A 3 % @ 400 Vac
LR3 40-4/1600 3 x 400 Vac 3 x 1600 A 4 % @ 400 Vac
LR3 40-5/1600 3 x 400 Vac 3 x 1600 A 5 % @ 400 Vac
Image of BLOCK Item: LR3 40-5/25
Approvals / Manufacturer's declaration EU-Declaration of Conformity

Technical Data for LR3 40-5/25

Operating data
Rated voltage 3 x 400 Vac
Rated voltage (IEC) 3 x 690 Vac
Rated voltage (UL) 3 x 600 Vac
Short circuit voltage uK 5 % @ 400 Vac
Voltage drop 11.6 Vac
Rated current 3 x 25 A
Rated frequency 50 - 60 Hz
Inductance 1.47 mH
Inductance deviation ±10%
Output
Power loss 87.1 W
Approvals
Approvals cURus
Environment
Ambient temperature 14 °F to +104 °F
Type of cooling AN
Safety and protection
Type Open type
Insulation class IEC=F, UL=class 155
Protection index IP 00
Safety class (prepared) I
Test voltage 4000 Vac
Terminal and mounting
Terminals phase Screw clamp, 10 mm²
Connection type for M4
Fixing method Fixing rail
Fixing screws M5
Measures and weights
Width 6.10 inch
Height 6.97 inch
Depth 4.33 inch
Weight 12.90 lbs

Information for LR3 400 series

General Data
  • Rated current 3 x 2 - 3 x 1600A
  • Ambient temperature 14 °F / -10 °C to +104 °F / +40 °C
  • Insulation class B, F or H
  • Inductance 0.019 - 18.500 mH
  • Short-circuit voltage (uK) 3 - 5 %
  • Rated voltage 3 x 400 Vac
  • Degree of protection IP 00
Benefits
  • Power harmonic mitigation
  • Ensuring the short-circuit voltage of 3, 4 or 5 % to the mains
  • Low ripple
  • Bridging voltage dips
  • Increases the service life of equipment
  • Starting current limitation
  • Use as line reactor, commutating reactor or PFC reactor
  • Peak current limitation
  • Very good corrosion protection and low noise due to vacuum impregnation
  • Integrated lifting rings
  • Multifunctional fixing rails

Our recommendations for you

BLOCK product: HF1K 18-400
HF1K 18-400
Harmonic filter
3 x 400 Vac, 3 x 10 – 3 x 144 A , 5.5 – 90 kW, Power factor >0,95 at rated current
View accessory
BLOCK product: LR3-AD025-404-0
LR3-AD025-404-0
Line reactor, three-phase
3 x 400 Vac, 3 x 4 - 3 x 900 A, 7,350 – 0,024 mH, Use as line reactor, commutating reactor or PFC reactor
View accessory
BLOCK product: HLD 110-500/30
HLD 110-500/30
Radio interference suppression filter, three-phase
3 x 520 Vac, 3 x 8 – 3 x 250 A, Leakage current 20.00 to 37.00 mA, For enhanced EMI suppression
View accessory