LR3 40-3/710
Line reactor LR3 400
Version LR3 40-3/710
Rated voltage
3 x 400 Vac
Rated current
3 x 710 A
Short circuit voltage uK
3 % @ 400 Vac
Version | Rated voltage | Rated current | Short circuit voltage uK | |
---|---|---|---|---|
LR3 40-3/2 | 3 x 400 Vac | 3 x 2 A | 3 % @ 400 Vac | |
LR3 40-4/2 | 3 x 400 Vac | 3 x 2 A | 4 % @ 400 Vac | |
LR3 40-5/2 | 3 x 400 Vac | 3 x 2 A | 5 % @ 400 Vac | |
LR3 40-3/4 | 3 x 400 Vac | 3 x 4 A | 3 % @ 400 Vac | |
LR3 40-4/4 | 3 x 400 Vac | 3 x 4 A | 4 % @ 400 Vac | |
LR3 40-5/4 | 3 x 400 Vac | 3 x 4 A | 5 % @ 400 Vac | |
LR3 40-3/6 | 3 x 400 Vac | 3 x 6 A | 3 % @ 400 Vac | |
LR3 40-4/6 | 3 x 400 Vac | 3 x 6 A | 4 % @ 400 Vac | |
LR3 40-5/6 | 3 x 400 Vac | 3 x 6 A | 5 % @ 400 Vac | |
LR3 40-3/8 | 3 x 400 Vac | 3 x 8 A | 3 % @ 400 Vac | |
LR3 40-4/8 | 3 x 400 Vac | 3 x 8 A | 4 % @ 400 Vac | |
LR3 40-5/8 | 3 x 400 Vac | 3 x 8 A | 5 % @ 400 Vac | |
LR3 40-3/10 | 3 x 400 Vac | 3 x 10 A | 3 % @ 400 Vac | |
LR3 40-4/10 | 3 x 400 Vac | 3 x 10 A | 4 % @ 400 Vac | |
LR3 40-5/10 | 3 x 400 Vac | 3 x 10 A | 5 % @ 400 Vac | |
LR3 40-3/16 | 3 x 400 Vac | 3 x 16 A | 3 % @ 400 Vac | |
LR3 40-4/16 | 3 x 400 Vac | 3 x 16 A | 4 % @ 400 Vac | |
LR3 40-5/16 | 3 x 400 Vac | 3 x 16 A | 5 % @ 400 Vac | |
LR3 40-3/20 | 3 x 400 Vac | 3 x 20 A | 3 % @ 400 Vac | |
LR3 40-4/20 | 3 x 400 Vac | 3 x 20 A | 4 % @ 400 Vac | |
LR3 40-5/20 | 3 x 400 Vac | 3 x 20 A | 5 % @ 400 Vac | |
LR3 40-3/25 | 3 x 400 Vac | 3 x 25 A | 3 % @ 400 Vac | |
LR3 40-4/25 | 3 x 400 Vac | 3 x 25 A | 4 % @ 400 Vac | |
LR3 40-5/25 | 3 x 400 Vac | 3 x 25 A | 5 % @ 400 Vac | |
LR3 40-3/30 | 3 x 400 Vac | 3 x 30 A | 3 % @ 400 Vac | |
LR3 40-4/30 | 3 x 400 Vac | 3 x 30 A | 4 % @ 400 Vac | |
LR3 40-5/30 | 3 x 400 Vac | 3 x 30 A | 5 % @ 400 Vac | |
LR3 40-3/35 | 3 x 400 Vac | 3 x 35 A | 3 % @ 400 Vac | |
LR3 40-4/35 | 3 x 400 Vac | 3 x 35 A | 4 % @ 400 Vac | |
LR3 40-5/35 | 3 x 400 Vac | 3 x 35 A | 5 % @ 400 Vac | |
LR3 40-3/40 | 3 x 400 Vac | 3 x 40 A | 3 % @ 400 Vac | |
LR3 40-4/40 | 3 x 400 Vac | 3 x 40 A | 4 % @ 400 Vac | |
LR3 40-5/40 | 3 x 400 Vac | 3 x 40 A | 5 % @ 400 Vac | |
LR3 40-3/45 | 3 x 400 Vac | 3 x 45 A | 3 % @ 400 Vac | |
LR3 40-4/45 | 3 x 400 Vac | 3 x 45 A | 4 % @ 400 Vac | |
LR3 40-5/45 | 3 x 400 Vac | 3 x 45 A | 5 % @ 400 Vac | |
LR3 40-3/50 | 3 x 400 Vac | 3 x 50 A | 3 % @ 400 Vac | |
LR3 40-4/50 | 3 x 400 Vac | 3 x 50 A | 4 % @ 400 Vac | |
LR3 40-5/50 | 3 x 400 Vac | 3 x 50 A | 5 % @ 400 Vac | |
LR3 40-3/63 | 3 x 400 Vac | 3 x 63 A | 3 % @ 400 Vac | |
LR3 40-4/63 | 3 x 400 Vac | 3 x 63 A | 4 % @ 400 Vac | |
LR3 40-5/63 | 3 x 400 Vac | 3 x 63 A | 5 % @ 400 Vac | |
LR3 40-3/70 | 3 x 400 Vac | 3 x 70 A | 3 % @ 400 Vac | |
LR3 40-4/70 | 3 x 400 Vac | 3 x 70 A | 4 % @ 400 Vac | |
LR3 40-5/70 | 3 x 400 Vac | 3 x 70 A | 5 % @ 400 Vac | |
LR3 40-3/80 | 3 x 400 Vac | 3 x 80 A | 3 % @ 400 Vac | |
LR3 40-4/80 | 3 x 400 Vac | 3 x 80 A | 4 % @ 400 Vac | |
LR3 40-5/80 | 3 x 400 Vac | 3 x 80 A | 5 % @ 400 Vac | |
LR3 40-3/90 | 3 x 400 Vac | 3 x 90 A | 3 % @ 400 Vac | |
LR3 40-4/90 | 3 x 400 Vac | 3 x 90 A | 4 % @ 400 Vac | |
LR3 40-5/90 | 3 x 400 Vac | 3 x 90 A | 5 % @ 400 Vac | |
LR3 40-3/100 | 3 x 400 Vac | 3 x 100 A | 3 % @ 400 Vac | |
LR3 40-4/100 | 3 x 400 Vac | 3 x 100 A | 4 % @ 400 Vac | |
LR3 40-5/100 | 3 x 400 Vac | 3 x 100 A | 5 % @ 400 Vac | |
LR3 40-3/115 | 3 x 400 Vac | 3 x 115 A | 3 % @ 400 Vac | |
LR3 40-4/115 | 3 x 400 Vac | 3 x 115 A | 4 % @ 400 Vac | |
LR3 40-5/115 | 3 x 400 Vac | 3 x 115 A | 5 % @ 400 Vac | |
LR3 40-3/125 | 3 x 400 Vac | 3 x 125 A | 3 % @ 400 Vac | |
LR3 40-4/125 | 3 x 400 Vac | 3 x 125 A | 4 % @ 400 Vac | |
LR3 40-5/125 | 3 x 400 Vac | 3 x 125 A | 5 % @ 400 Vac | |
LR3 40-3/160 | 3 x 400 Vac | 3 x 160 A | 3 % @ 400 Vac | |
LR3 40-4/160 | 3 x 400 Vac | 3 x 160 A | 4 % @ 400 Vac | |
LR3 40-5/160 | 3 x 400 Vac | 3 x 160 A | 5 % @ 400 Vac | |
LR3 40-3/180 | 3 x 400 Vac | 3 x 180 A | 3 % @ 400 Vac | |
LR3 40-4/180 | 3 x 400 Vac | 3 x 180 A | 4 % @ 400 Vac | |
LR3 40-5/180 | 3 x 400 Vac | 3 x 180 A | 5 % @ 400 Vac | |
LR3 40-3/200 | 3 x 400 Vac | 3 x 200 A | 3 % @ 400 Vac | |
LR3 40-4/200 | 3 x 400 Vac | 3 x 200 A | 4 % @ 400 Vac | |
LR3 40-5/200 | 3 x 400 Vac | 3 x 200 A | 5 % @ 400 Vac | |
LR3 40-3/250 | 3 x 400 Vac | 3 x 250 A | 3 % @ 400 Vac | |
LR3 40-4/250 | 3 x 400 Vac | 3 x 250 A | 4 % @ 400 Vac | |
LR3 40-5/250 | 3 x 400 Vac | 3 x 250 A | 5 % @ 400 Vac | |
LR3 40-3/300 | 3 x 400 Vac | 3 x 300 A | 3 % @ 400 Vac | |
LR3 40-4/300 | 3 x 400 Vac | 3 x 300 A | 4 % @ 400 Vac | |
LR3 40-5/300 | 3 x 400 Vac | 3 x 300 A | 5 % @ 400 Vac | |
LR3 40-3/400 | 3 x 400 Vac | 3 x 400 A | 3 % @ 400 Vac | |
LR3 40-4/400 | 3 x 400 Vac | 3 x 400 A | 4 % @ 400 Vac | |
LR3 40-5/400 | 3 x 400 Vac | 3 x 400 A | 5 % @ 400 Vac | |
LR3 40-3/500 | 3 x 400 Vac | 3 x 500 A | 3 % @ 400 Vac | |
LR3 40-4/500 | 3 x 400 Vac | 3 x 500 A | 4 % @ 400 Vac | |
LR3 40-5/500 | 3 x 400 Vac | 3 x 500 A | 5 % @ 400 Vac | |
LR3 40-3/630 | 3 x 400 Vac | 3 x 630 A | 3 % @ 400 Vac | |
LR3 40-4/630 | 3 x 400 Vac | 3 x 630 A | 4 % @ 400 Vac | |
LR3 40-5/630 | 3 x 400 Vac | 3 x 630 A | 5 % @ 400 Vac | |
LR3 40-3/710 | 3 x 400 Vac | 3 x 710 A | 3 % @ 400 Vac | |
LR3 40-4/710 | 3 x 400 Vac | 3 x 710 A | 4 % @ 400 Vac | |
LR3 40-5/710 | 3 x 400 Vac | 3 x 710 A | 5 % @ 400 Vac | |
LR3 40-3/800 | 3 x 400 Vac | 3 x 800 A | 3 % @ 400 Vac | |
LR3 40-4/800 | 3 x 400 Vac | 3 x 800 A | 4 % @ 400 Vac | |
LR3 40-5/800 | 3 x 400 Vac | 3 x 800 A | 5 % @ 400 Vac | |
LR3 40-3/1000 | 3 x 400 Vac | 3 x 1000 A | 3 % @ 400 Vac | |
LR3 40-4/1000 | 3 x 400 Vac | 3 x 1000 A | 4 % @ 400 Vac | |
LR3 40-5/1000 | 3 x 400 Vac | 3 x 1000 A | 5 % @ 400 Vac | |
LR3 40-3/1200 | 3 x 400 Vac | 3 x 1200 A | 3 % @ 400 Vac | |
LR3 40-4/1200 | 3 x 400 Vac | 3 x 1200 A | 4 % @ 400 Vac | |
LR3 40-5/1200 | 3 x 400 Vac | 3 x 1200 A | 5 % @ 400 Vac | |
LR3 40-3/1400 | 3 x 400 Vac | 3 x 1400 A | 3 % @ 400 Vac | |
LR3 40-4/1400 | 3 x 400 Vac | 3 x 1400 A | 4 % @ 400 Vac | |
LR3 40-5/1400 | 3 x 400 Vac | 3 x 1400 A | 5 % @ 400 Vac | |
LR3 40-3/1600 | 3 x 400 Vac | 3 x 1600 A | 3 % @ 400 Vac | |
LR3 40-4/1600 | 3 x 400 Vac | 3 x 1600 A | 4 % @ 400 Vac | |
LR3 40-5/1600 | 3 x 400 Vac | 3 x 1600 A | 5 % @ 400 Vac |
Technical Data for LR3 40-3/710
Operating data | |
---|---|
Rated voltage | 3 x 400 Vac |
Rated voltage (IEC) | 3 x 690 Vac |
Rated voltage (UL) | 3 x 600 Vac |
Short circuit voltage uK | 3 % @ 400 Vac |
Voltage drop | 6.9 Vac |
Rated current | 3 x 710 A |
Rated frequency | 50 - 60 Hz |
Inductance | 0.031 mH |
Inductance deviation | ±10% |
Output | |
---|---|
Power loss | 1738 W |
Approvals | |
---|---|
Approvals | cURus |
Environment | |
---|---|
Ambient temperature | 14 °F to +104 °F |
Type of cooling | AN |
Safety and protection | |
---|---|
Type | Open type |
Insulation class | IEC=H, UL=class 180 |
Protection index | IP 00 |
Safety class (prepared) | I |
Test voltage | 4000 Vac |
Terminal and mounting | |
---|---|
Terminals phase | Flat copper |
Connection type | for M8 |
Fixing method | Fixing rail |
Fixing screws | M8 |
Measures and weights | |
---|---|
Width | 16.22 inch |
Height | 12.40 inch |
Depth | 7.28 inch |
Weight | 161.27 lbs |
Information for LR3 400 series
General Data
- Rated current 3 x 2 - 3 x 1600A
- Ambient temperature 14 °F / -10 °C to +104 °F / +40 °C
- Insulation class B, F or H
- Inductance 0.019 - 18.500 mH
- Short-circuit voltage (uK) 3 - 5 %
- Rated voltage 3 x 400 Vac
- Degree of protection IP 00
Benefits
- Power harmonic mitigation
- Ensuring the short-circuit voltage of 3, 4 or 5 % to the mains
- Low ripple
- Bridging voltage dips
- Increases the service life of equipment
- Starting current limitation
- Use as line reactor, commutating reactor or PFC reactor
- Peak current limitation
- Very good corrosion protection and low noise due to vacuum impregnation
- Integrated lifting rings
- Multifunctional fixing rails