FL 42/18

Safety isolating transformer

Version FL 42/18
Rated input voltage 2 x 115 Vac Rated output voltage 2 x 18 Vac Power 42 VA
Version Rated input voltage Rated output voltage Power
FL 2/5 2 x 115 Vac 2 x 5 Vac 2 VA
FL 2/6 2 x 115 Vac 2 x 6 Vac 2 VA
FL 2/8 2 x 115 Vac 2 x 8 Vac 2 VA
FL 2/9 2 x 115 Vac 2 x 9 Vac 2 VA
FL 2/12 2 x 115 Vac 2 x 12 Vac 2 VA
FL 2/15 2 x 115 Vac 2 x 15 Vac 2 VA
FL 2/24 2 x 115 Vac 2 x 24 Vac 2 VA
FL 4/5 2 x 115 Vac 2 x 5 Vac 4 VA
FL 4/6 2 x 115 Vac 2 x 6 Vac 4 VA
FL 4/8 2 x 115 Vac 2 x 8 Vac 4 VA
FL 4/9 2 x 115 Vac 2 x 9 Vac 4 VA
FL 4/12 2 x 115 Vac 2 x 12 Vac 4 VA
FL 4/15 2 x 115 Vac 2 x 15 Vac 4 VA
FL 4/18 2 x 115 Vac 2 x 18 Vac 4 VA
FL 4/24 2 x 115 Vac 2 x 24 Vac 4 VA
FL 6/5 2 x 115 Vac 2 x 5 Vac 6 VA
FL 6/6 2 x 115 Vac 2 x 6 Vac 6 VA
FL 6/8 2 x 115 Vac 2 x 8 Vac 6 VA
FL 6/9 2 x 115 Vac 2 x 9 Vac 6 VA
FL 6/12 2 x 115 Vac 2 x 12 Vac 6 VA
FL 6/15 2 x 115 Vac 2 x 15 Vac 6 VA
FL 6/18 2 x 115 Vac 2 x 18 Vac 6 VA
FL 6/24 2 x 115 Vac 2 x 24 Vac 6 VA
FL 8/6 2 x 115 Vac 2 x 6 Vac 8 VA
FL 8/8 2 x 115 Vac 2 x 8 Vac 8 VA
FL 8/9 2 x 115 Vac 2 x 9 Vac 8 VA
FL 8/12 2 x 115 Vac 2 x 12 Vac 8 VA
FL 8/15 2 x 115 Vac 2 x 15 Vac 8 VA
FL 8/18 2 x 115 Vac 2 x 18 Vac 8 VA
FL 8/24 2 x 115 Vac 2 x 24 Vac 8 VA
FL 10/5 2 x 115 Vac 2 x 5 Vac 10 VA
FL 10/6 2 x 115 Vac 2 x 6 Vac 10 VA
FL 10/8 2 x 115 Vac 2 x 8 Vac 10 VA
FL 10/9 2 x 115 Vac 2 x 9 Vac 10 VA
FL 10/12 2 x 115 Vac 2 x 12 Vac 10 VA
FL 10/15 2 x 115 Vac 2 x 15 Vac 10 VA
FL 10/18 2 x 115 Vac 2 x 18 Vac 10 VA
FL 10/24 2 x 115 Vac 2 x 24 Vac 10 VA
FL 14/5 2 x 115 Vac 2 x 5 Vac 14 VA
FL 14/6 2 x 115 Vac 2 x 6 Vac 14 VA
FL 14/8 2 x 115 Vac 2 x 8 Vac 14 VA
FL 14/9 2 x 115 Vac 2 x 9 Vac 14 VA
FL 14/12 2 x 115 Vac 2 x 12 Vac 14 VA
FL 14/15 2 x 115 Vac 2 x 15 Vac 14 VA
FL 14/18 2 x 115 Vac 2 x 18 Vac 14 VA
FL 14/24 2 x 115 Vac 2 x 24 Vac 14 VA
FL 18/5 2 x 115 Vac 2 x 5 Vac 18 VA
FL 18/6 2 x 115 Vac 2 x 6 Vac 18 VA
FL 18/8 2 x 115 Vac 2 x 8 Vac 18 VA
FL 18/9 2 x 115 Vac 2 x 9 Vac 18 VA
FL 18/12 2 x 115 Vac 2 x 12 Vac 18 VA
FL 18/15 2 x 115 Vac 2 x 15 Vac 18 VA
FL 18/18 2 x 115 Vac 2 x 18 Vac 18 VA
FL 18/24 2 x 115 Vac 2 x 24 Vac 18 VA
FL 24/5 2 x 115 Vac 2 x 5 Vac 24 VA
FL 24/6 2 x 115 Vac 2 x 6 Vac 24 VA
FL 24/8 2 x 115 Vac 2 x 8 Vac 24 VA
FL 24/9 2 x 115 Vac 2 x 9 Vac 24 VA
FL 24/12 2 x 115 Vac 2 x 12 Vac 24 VA
FL 24/15 2 x 115 Vac 2 x 15 Vac 24 VA
FL 24/18 2 x 115 Vac 2 x 18 Vac 24 VA
FL 24/24 2 x 115 Vac 2 x 24 Vac 24 VA
FL 30/5 2 x 115 Vac 2 x 5 Vac 30 VA
FL 30/6 2 x 115 Vac 2 x 6 Vac 30 VA
FL 30/8 2 x 115 Vac 2 x 8 Vac 30 VA
FL 30/9 2 x 115 Vac 2 x 9 Vac 30 VA
FL 30/12 2 x 115 Vac 2 x 12 Vac 30 VA
FL 30/15 2 x 115 Vac 2 x 15 Vac 30 VA
FL 30/18 2 x 115 Vac 2 x 18 Vac 30 VA
FL 30/24 2 x 115 Vac 2 x 24 Vac 30 VA
FL 42/5 2 x 115 Vac 2 x 5 Vac 42 VA
FL 42/6 2 x 115 Vac 2 x 6 Vac 42 VA
FL 42/8 2 x 115 Vac 2 x 8 Vac 42 VA
FL 42/9 2 x 115 Vac 2 x 9 Vac 42 VA
FL 42/12 2 x 115 Vac 2 x 12 Vac 42 VA
FL 42/15 2 x 115 Vac 2 x 15 Vac 42 VA
FL 42/18 2 x 115 Vac 2 x 18 Vac 42 VA
FL 42/24 2 x 115 Vac 2 x 24 Vac 42 VA
FL 52/5 2 x 115 Vac 2 x 5 Vac 52 VA
FL 52/6 2 x 115 Vac 2 x 6 Vac 52 VA
FL 52/8 2 x 115 Vac 2 x 8 Vac 52 VA
FL 52/9 2 x 115 Vac 2 x 9 Vac 52 VA
FL 52/12 2 x 115 Vac 2 x 12 Vac 52 VA
FL 52/15 2 x 115 Vac 2 x 15 Vac 52 VA
FL 52/18 2 x 115 Vac 2 x 18 Vac 52 VA
FL 52/24 2 x 115 Vac 2 x 24 Vac 52 VA

Technical Data for FL 42/18

Input
Rated input voltage 2 x 115 Vac
Rated frequency 50 - 60 Hz
Output
Rated output voltage 2 x 18 Vac
Power 42 VA
No-load voltage (app. x factor) 1.16
No-load loss (typ.) 3.5 W
Efficiency 81 %
Standards
Classification Safety isolating transformer
Approvals
Approvals cURus, VDE
Environment
Ambient temperature max. 104.0 °F
Safety and protection
Type Encapsulated
Insulation class VDE=E, UL=class 105
Protection index IP 00
Safety class (prepared) II
Short circuit strength non-short-circuit proof
Terminal and mounting
Terminals Pins for PCB
Measures and weights
Depth 3.29 inch
Height 1.54 inch
Width 2.76 inch
Core type UI 48/17
Weight 1.59 lbs

Information for FL series

General Data
  • Rated power 2 - 52 VA
  • Efficiency up to 81 %
  • Insulation class E
  • Maximum ambient temperature 104 °F / 40 °C
  • Rated output voltage 2 x 5 - 2 x 24 Vac
  • Rated input voltage 2 x 115 Vac
  • Degree of protection IP 00
Benefits
  • Dual output voltage for series or parallel connection
  • Minimum size at high output
  • Dual input voltage for series or parallel connection
  • Permanent corrosion protection, high insulation value and maximum electrical reliability due to XtraDenseFill resin encapsulation
  • Self-extinguishing potting material
  • Low height