LR3-AE630-404-0

Line reactor LR3-A

Version LR3-AE630-404-0
Rated voltage 3 x 400 Vac Rated current 3 x 630 A Short circuit voltage uK 4 %
Version Rated voltage Rated current Short circuit voltage uK
LR3-AD004-404-0 3 x 400 Vac 3 x 4 A 4 %
LR3-AD006-404-0 3 x 400 Vac 3 x 6 A 4 %
LR3-AD008-404-0 3 x 400 Vac 3 x 8 A 4 %
LR3-AD010-404-0 3 x 400 Vac 3 x 10 A 4 %
LR3-AD016-404-0 3 x 400 Vac 3 x 16 A 4 %
LR3-AD020-404-0 3 x 400 Vac 3 x 20 A 4 %
LR3-AD025-404-0 3 x 400 Vac 3 x 25 A 4 %
LR3-AD030-404-0 3 x 400 Vac 3 x 30 A 4 %
LR3-AD035-404-0 3 x 400 Vac 3 x 35 A 4 %
LR3-AD040-404-0 3 x 400 Vac 3 x 40 A 4 %
LR3-AD045-404-0 3 x 400 Vac 3 x 45 A 4 %
LR3-AD050-404-0 3 x 400 Vac 3 x 50 A 4 %
LR3-AD063-404-0 3 x 400 Vac 3 x 63 A 4 %
LR3-AE063-404-0 3 x 400 Vac 3 x 63 A 4 %
LR3-AD080-404-0 3 x 400 Vac 3 x 80 A 4 %
LR3-AE080-404-0 3 x 400 Vac 3 x 80 A 4 %
LR3-AE100-404-0 3 x 400 Vac 3 x 100 A 4 %
LR3-AE125-404-0 3 x 400 Vac 3 x 125 A 4 %
LR3-AE160-404-0 3 x 400 Vac 3 x 160 A 4 %
LR3-AE200-404-0 3 x 400 Vac 3 x 200 A 4 %
LR3-AE250-404-0 3 x 400 Vac 3 x 250 A 4 %
LR3-AE315-404-0 3 x 400 Vac 3 x 315 A 4 %
LR3-AE400-404-0 3 x 400 Vac 3 x 400 A 4 %
LR3-AE500-404-0 3 x 400 Vac 3 x 500 A 4 %
LR3-AE630-404-0 3 x 400 Vac 3 x 630 A 4 %
LR3-AE710-404-0 3 x 400 Vac 3 x 710 A 4 %
LR3-AE900-404-0 3 x 400 Vac 3 x 900 A 4 %
Image of %s BLOCK Item: LR3-AE630-404-0

Technical data for LR3-AE630-404-0

Operating data
Rated voltage 3 x 400 Vac
Rated voltage (IEC) 3 x 690 Vac
Rated voltage (UL) 3 x 600 Vac
Short circuit voltage uK 4 %
Voltage drop 9.2 Vac
Rated current 3 x 630 A
Rated frequency 50 - 60 Hz
Inductance 0.047 mH
Inductance deviation ±10%
Approvals
Approvals -
Environment
Ambient temperature +40 °C
Type of cooling AN
Safety and protection
Type Open type
Insulation class H
Protection index IP 00
Safety class I
Test voltage 2500 Vac
Terminal and mounting
Terminals phase Bolt, 2x M8
Terminals PE Bolt, M10
Fixing method Fixing rail
Fixing screws M10
Measures and weights
Width 500 mm
Height 251 mm
Depth 283 mm
Weight 62.00 kg

Info on LR3-A series

General Data
  • Degree of protection IP 00
  • Rated voltage 3 x 400 Vac
  • Short-circuit voltage (uK) 4 %
  • Rated current 3 x 4 - 3 x 80 A
  • Inductance 7,350 – 0,370 mH
  • Insulation class H
  • Ambient temperature +40 °C
Benefits
  • Use as line reactor, commutating reactor or PFC reactor
  • Increases the service life of consumers
  • Low ripple
  • Ensuring the short-circuit voltage of 4 % to the mains
  • Power harmonic damping
  • Starting current limitation
  • Bridging voltage dips
  • Peak current limitation
  • Very good corrosion protection and low noise thanks to vacuum impregnation
  • AD types with UL approval, AE types UL in preparation