LR3-AD025-404-0

Line reactor LR3-A

Version LR3-AD025-404-0
Rated voltage 3 x 400 Vac Rated current 3 x 25 A Short circuit voltage uK 4 % @ 400 Vac
Version Rated voltage Rated current Short circuit voltage uK
LR3-AD004-404-0 3 x 400 Vac 3 x 4 A 4 % @ 400 Vac
LR3-AD006-404-0 3 x 400 Vac 3 x 6 A 4 % @ 400 Vac
LR3-AD008-404-0 3 x 400 Vac 3 x 8 A 4 % @ 400 Vac
LR3-AD010-404-0 3 x 400 Vac 3 x 10 A 4 % @ 400 Vac
LR3-AD016-404-0 3 x 400 Vac 3 x 16 A 4 % @ 400 Vac
LR3-AD020-404-0 3 x 400 Vac 3 x 20 A 4 % @ 400 Vac
LR3-AD025-404-0 3 x 400 Vac 3 x 25 A 4 % @ 400 Vac
LR3-AD030-404-0 3 x 400 Vac 3 x 30 A 4 % @ 400 Vac
LR3-AD035-404-0 3 x 400 Vac 3 x 35 A 4 % @ 400 Vac
LR3-AD040-404-0 3 x 400 Vac 3 x 40 A 4 % @ 400 Vac
LR3-AD045-404-0 3 x 400 Vac 3 x 45 A 4 % @ 400 Vac
LR3-AD050-404-0 3 x 400 Vac 3 x 50 A 4 % @ 400 Vac
LR3-AD063-404-0 3 x 400 Vac 3 x 63 A 4 % @ 400 Vac
LR3-AE063-404-0 3 x 400 Vac 3 x 63 A 4 % @ 400 Vac
LR3-AD080-404-0 3 x 400 Vac 3 x 80 A 4 % @ 400 Vac
LR3-AE080-404-0 3 x 400 Vac 3 x 80 A 4 % @ 400 Vac
LR3-AE100-404-0 3 x 400 Vac 3 x 100 A 4 % @ 400 Vac
LR3-AE125-404-0 3 x 400 Vac 3 x 125 A 4 % @ 400 Vac
LR3-AE160-404-0 3 x 400 Vac 3 x 160 A 4 % @ 400 Vac
LR3-AE200-404-0 3 x 400 Vac 3 x 200 A 4 % @ 400 Vac
LR3-AE250-404-0 3 x 400 Vac 3 x 250 A 4 % @ 400 Vac
LR3-AE315-404-0 3 x 400 Vac 3 x 315 A 4 % @ 400 Vac
LR3-AE400-404-0 3 x 400 Vac 3 x 400 A 4 % @ 400 Vac
LR3-AE500-404-0 3 x 400 Vac 3 x 500 A 4 % @ 400 Vac
LR3-AE630-404-0 3 x 400 Vac 3 x 630 A 4 % @ 400 Vac
LR3-AE710-404-0 3 x 400 Vac 3 x 710 A 4 % @ 400 Vac
LR3-AE900-404-0 3 x 400 Vac 3 x 900 A 4 % @ 400 Vac
LR3-AE063-483-0 3 x 480 Vac 3 x 63 A 3 % @ 480 Vac
LR3-AE063-485-0 3 x 480 Vac 3 x 63 A 5 % @ 480 Vac
LR3-AE080-483-0 3 x 480 Vac 3 x 80 A 3 % @ 480 Vac
LR3-AE080-485-0 3 x 480 Vac 3 x 80 A 5 % @ 480 Vac
LR3-AE100-483-0 3 x 480 Vac 3 x 100 A 3 % @ 480 Vac
LR3-AE100-485-0 3 x 480 Vac 3 x 100 A 5 % @ 480 Vac
LR3-AE125-483-0 3 x 480 Vac 3 x 125 A 3 % @ 480 Vac
LR3-AE125-485-0 3 x 480 Vac 3 x 125 A 5 % @ 480 Vac
LR3-AE160-483-0 3 x 480 Vac 3 x 160 A 3 % @ 480 Vac
LR3-AE160-485-0 3 x 480 Vac 3 x 160 A 5 % @ 480 Vac
LR3-AE200-483-0 3 x 480 Vac 3 x 200 A 3 % @ 480 Vac
LR3-AE200-485-0 3 x 480 Vac 3 x 200 A 5 % @ 480 Vac
LR3-AE250-483-0 3 x 480 Vac 3 x 250 A 3 % @ 480 Vac
LR3-AE250-485-0 3 x 480 Vac 3 x 250 A 5 % @ 480 Vac
LR3-AE315-483-0 3 x 480 Vac 3 x 315 A 3 % @ 480 Vac
LR3-AE315-485-0 3 x 480 Vac 3 x 315 A 5 % @ 480 Vac
LR3-AE400-483-0 3 x 480 Vac 3 x 400 A 3 % @ 480 Vac
LR3-AE400-485-0 3 x 480 Vac 3 x 400 A 5 % @ 480 Vac
LR3-AE500-483-0 3 x 480 Vac 3 x 500 A 3 % @ 480 Vac
LR3-AE500-485-0 3 x 480 Vac 3 x 500 A 5 % @ 480 Vac
LR3-AE630-483-0 3 x 480 Vac 3 x 630 A 3 % @ 480 Vac
LR3-AE630-485-0 3 x 480 Vac 3 x 630 A 5 % @ 480 Vac
LR3-AE710-483-0 3 x 480 Vac 3 x 710 A 3 % @ 480 Vac
LR3-AE710-485-0 3 x 480 Vac 3 x 710 A 5 % @ 480 Vac
LR3-AE900-483-0 3 x 480 Vac 3 x 900 A 3 % @ 480 Vac
LR3-AE900-485-0 3 x 480 Vac 3 x 900 A 5 % @ 480 Vac
Image of %s BLOCK Item: LR3-AD025-404-0

Technical data for LR3-AD025-404-0

Operating data
Rated voltage 3 x 400 Vac
Rated voltage (IEC) 3 x 690 Vac
Rated voltage (UL) 3 x 600 Vac
Short circuit voltage uK 4 % @ 400 Vac
Voltage drop 9.2 Vac
Rated current 3 x 25 A
Rated frequency 50 - 60 Hz
Inductance 1.180 mH
Inductance deviation ±10%
Approvals
Approvals cURus
Environment
Ambient temperature +40 °C
Type of cooling AN
Safety and protection
Type Open type
Insulation class H
Protection index IP 00
Safety class I
Test voltage 2500 Vac
Terminal and mounting
Terminals phase Screw clamp, 4 mm²
Terminals PE for M5
Fixing method Fixing rail
Fixing screws M5
Measures and weights
Width 155 mm
Height 165 mm
Depth 110 mm
Weight 5.70 kg

Info on LR3-A series

General Data
  • Rated current 3 x 4 - 3 x 900 A
  • Insulation class H
  • Inductance 7,350 – 0,024 mH
  • Short-circuit voltage (uK) 3 %, 4 %, 5%
  • Rated voltage 3 x 400 Vac, 3 x 480 Vac
  • Degree of protection IP 00
  • Ambient temperature +40 °C
Benefits
  • Ensuring the short-circuit voltage of 3, 4 or 5 % to the mains
  • Increases the service life of consumers
  • Low ripple
  • Starting current limitation
  • Power harmonic damping
  • Use as line reactor, commutating reactor or PFC reactor
  • Bridging voltage dips
  • Peak current limitation
  • Very good corrosion protection and low noise thanks to vacuum impregnation
  • AD types with UL approval, AE types with UL Listed approval

Our recommendations for you

BLOCK product: HF1K 18-400
HF1K 18-400
Harmonic filter
3 x 400 Vac, 3 x 10 – 3 x 144 A , 5.5 – 90 kW, Cos(phi)>0,95 at rated current
to accessory part
BLOCK product: LR3 40-4/25
LR3 40-4/25
Line reactor, three-phase
3 x 400 Vac, 3 x 2 – 3 x 1600 A, 0.019 – 18.500 mH, Use as line reactor, commutating reactor or PFC reactor
to accessory part
BLOCK product: HLD 110-500/30
HLD 110-500/30
Radio interference suppression filter, three-phase
3 x 520 Vac, 3 x 8 – 3 x 250 A, Leakage current 20.00 - 37.00 mA, For enhanced requirements
to accessory part