LR3 48-5/1000

Line reactor LR3 480

Version LR3 48-5/1000
Rated voltage 3 x 480 Vac Rated current 1000 A Short circuit voltage uK 5 %
Version Rated voltage Rated current Short circuit voltage uK
LR3 48-3/2 3 x 480 Vac 2 A 3 %
LR3 48-4/2 3 x 480 Vac 2 A 4 %
LR3 48-5/2 3 x 480 Vac 2 A 5 %
LR3 48-3/4 3 x 480 Vac 4 A 3 %
LR3 48-4/4 3 x 480 Vac 4 A 4 %
LR3 48-5/4 3 x 480 Vac 4 A 5 %
LR3 48-3/6 3 x 480 Vac 6 A 3 %
LR3 48-4/6 3 x 480 Vac 6 A 4 %
LR3 48-5/6 3 x 480 Vac 6 A 5 %
LR3 48-3/8 3 x 480 Vac 8 A 3 %
LR3 48-4/8 3 x 480 Vac 8 A 4 %
LR3 48-5/8 3 x 480 Vac 8 A 5 %
LR3 48-3/10 3 x 480 Vac 10 A 3 %
LR3 48-4/10 3 x 480 Vac 10 A 4 %
LR3 48-5/10 3 x 480 Vac 10 A 5 %
LR3 48-3/16 3 x 480 Vac 16 A 3 %
LR3 48-4/16 3 x 480 Vac 16 A 4 %
LR3 48-5/16 3 x 480 Vac 16 A 5 %
LR3 48-3/20 3 x 480 Vac 20 A 3 %
LR3 48-4/20 3 x 480 Vac 20 A 4 %
LR3 48-5/20 3 x 480 Vac 20 A 5 %
LR3 48-3/25 3 x 480 Vac 25 A 3 %
LR3 48-4/25 3 x 480 Vac 25 A 4 %
LR3 48-5/25 3 x 480 Vac 25 A 5 %
LR3 48-3/30 3 x 480 Vac 30 A 3 %
LR3 48-4/30 3 x 480 Vac 30 A 4 %
LR3 48-5/30 3 x 480 Vac 30 A 5 %
LR3 48-3/35 3 x 480 Vac 35 A 3 %
LR3 48-4/35 3 x 480 Vac 35 A 4 %
LR3 48-5/35 3 x 480 Vac 35 A 5 %
LR3 48-3/40 3 x 480 Vac 40 A 3 %
LR3 48-4/40 3 x 480 Vac 40 A 4 %
LR3 48-5/40 3 x 480 Vac 40 A 5 %
LR3 48-3/45 3 x 480 Vac 45 A 3 %
LR3 48-4/45 3 x 480 Vac 45 A 4 %
LR3 48-5/45 3 x 480 Vac 45 A 5 %
LR3 48-3/50 3 x 480 Vac 50 A 3 %
LR3 48-4/50 3 x 480 Vac 50 A 4 %
LR3 48-5/50 3 x 480 Vac 50 A 5 %
LR3 48-3/63 3 x 480 Vac 63 A 3 %
LR3 48-4/63 3 x 480 Vac 63 A 4 %
LR3 48-5/63 3 x 480 Vac 63 A 5 %
LR3 48-3/70 3 x 480 Vac 70 A 3 %
LR3 48-4/70 3 x 480 Vac 70 A 4 %
LR3 48-5/70 3 x 480 Vac 70 A 5 %
LR3 48-3/80 3 x 480 Vac 80 A 3 %
LR3 48-4/80 3 x 480 Vac 80 A 4 %
LR3 48-5/80 3 x 480 Vac 80 A 5 %
LR3 48-3/90 3 x 480 Vac 90 A 3 %
LR3 48-4/90 3 x 480 Vac 90 A 4 %
LR3 48-5/90 3 x 480 Vac 90 A 5 %
LR3 48-3/100 3 x 480 Vac 100 A 3 %
LR3 48-4/100 3 x 480 Vac 100 A 4 %
LR3 48-5/100 3 x 480 Vac 100 A 5 %
LR3 48-3/115 3 x 480 Vac 115 A 3 %
LR3 48-4/115 3 x 480 Vac 115 A 4 %
LR3 48-5/115 3 x 480 Vac 115 A 5 %
LR3 48-3/125 3 x 480 Vac 125 A 3 %
LR3 48-4/125 3 x 480 Vac 125 A 4 %
LR3 48-5/125 3 x 480 Vac 125 A 5 %
LR3 48-3/160 3 x 480 Vac 160 A 3 %
LR3 48-4/160 3 x 480 Vac 160 A 4 %
LR3 48-5/160 3 x 480 Vac 160 A 5 %
LR3 48-3/180 3 x 480 Vac 180 A 3 %
LR3 48-4/180 3 x 480 Vac 180 A 4 %
LR3 48-5/180 3 x 480 Vac 180 A 5 %
LR3 48-3/200 3 x 480 Vac 200 A 3 %
LR3 48-4/200 3 x 480 Vac 200 A 4 %
LR3 48-5/200 3 x 480 Vac 200 A 5 %
LR3 48-3/250 3 x 480 Vac 250 A 3 %
LR3 48-4/250 3 x 480 Vac 250 A 4 %
LR3 48-5/250 3 x 480 Vac 250 A 5 %
LR3 48-3/300 3 x 480 Vac 300 A 3 %
LR3 48-4/300 3 x 480 Vac 300 A 4 %
LR3 48-5/300 3 x 480 Vac 300 A 5 %
LR3 48-3/400 3 x 480 Vac 400 A 3 %
LR3 48-4/400 3 x 480 Vac 400 A 4 %
LR3 48-5/400 3 x 480 Vac 400 A 5 %
LR3 48-3/500 3 x 480 Vac 500 A 3 %
LR3 48-4/500 3 x 480 Vac 500 A 4 %
LR3 48-5/500 3 x 480 Vac 500 A 5 %
LR3 48-3/630 3 x 480 Vac 630 A 3 %
LR3 48-4/630 3 x 480 Vac 630 A 4 %
LR3 48-5/630 3 x 480 Vac 630 A 5 %
LR3 48-3/710 3 x 480 Vac 710 A 3 %
LR3 48-4/710 3 x 480 Vac 710 A 4 %
LR3 48-5/710 3 x 480 Vac 710 A 5 %
LR3 48-3/800 3 x 480 Vac 800 A 3 %
LR3 48-4/800 3 x 480 Vac 800 A 4 %
LR3 48-5/800 3 x 480 Vac 800 A 5 %
LR3 48-3/1000 3 x 480 Vac 1000 A 3 %
LR3 48-4/1000 3 x 480 Vac 1000 A 4 %
LR3 48-5/1000 3 x 480 Vac 1000 A 5 %
LR3 48-3/1200 3 x 480 Vac 1200 A 3 %
LR3 48-4/1200 3 x 480 Vac 1200 A 4 %
LR3 48-5/1200 3 x 480 Vac 1200 A 5 %
LR3 48-3/1400 3 x 480 Vac 1400 A 3 %
LR3 48-4/1400 3 x 480 Vac 1400 A 4 %
LR3 48-5/1400 3 x 480 Vac 1400 A 5 %
LR3 48-3/1600 3 x 480 Vac 1600 A 3 %
LR3 48-4/1600 3 x 480 Vac 1600 A 4 %
LR3 48-5/1600 3 x 480 Vac 1600 A 5 %
Image of %s BLOCK Item: LR3 48-5/1000

Technical data for LR3 48-5/1000

Operating data
Rated voltage 3 x 480 Vac
Short circuit voltage uK 5 %
Voltage drop 13.9 Vac
Rated current 1000 A
Rated frequency 50 - 60 Hz
Inductance 0.037 mH
Inductance deviation ±10%
Approvals
Approvals cURus, cULus
Environment
Ambient temperature -10 °C to +40 °C
Type of cooling AN
Safety and protection
Type Open type
Insulation class IEC=H, UL=class 180
Protection index IP 00
Safety class (prepared) I
Test voltage 4000 Vac
Terminal and mounting
Terminals phase Flat copper
Terminals PE for M16
Fixing method Fixing rail
Fixing screws M10
Measures and weights
Width 552 mm
Height 410 mm
Depth 193 mm
Weight 134.4 kg

Info on LR3 480 series

General Data
  • Rated current 3 x 2 - 3 x 1600 A
  • Degree of protection IP 00
  • Ambient temperature -10 °C to +40 °C
  • Inductance 0.014 - 18.500 mH
  • Insulation class B, F or H
  • Short-circuit voltage (uK) 3 - 5 %
  • Rated voltage 3 x 480 Vac
Benefits
  • Low ripple
  • Power harmonic damping
  • Use as line reactor, commutating reactor or PFC reactor
  • Ensuring the short-circuit voltage of 3 - 5 % to the mains
  • Increases the service life of consumers
  • Multifunctional fixing rails
  • Bridging voltage dips
  • Peak current limitation
  • Starting current limitation
  • Very good corrosion protection and low noise thanks to vacuum impregnation
  • Integrated lifting rings

Our recommendations for you

BLOCK product: HFM-FB 255-400
HFM-FB 255-400
Harmonic filter
3 x 400 Vac, 3 x 10.00 – 3 x 433.00 A, 5 – 250 kW, Cos(phi)>0.95 at rated current
to accessory part
BLOCK product: HLD 103-500/1000
HLD 103-500/1000
Radio interference suppression filter, three-phase
3 x 520 Vac, 3 x 270 – 3 x 1800 A, Leakage current 60.00 mA, For enhanced requirements
to accessory part
BLOCK product: SFB 400/480
SFB 400/480
Sine filter
3 x 400 Vac, 4 – 480 A, For motor rated output 1.5 – 260 kW, For switching frequencies of 4 to 8 kHz
to accessory part