LR3 48-3/1000
Line reactor LR3 480
Rated voltage
3 x 480 Vac
Rated current
1000 A
Short circuit voltage uK
3 % @ 480 Vac
Version | Rated voltage | Rated current | Short circuit voltage uK | |
---|---|---|---|---|
LR3 48-3/2 | 3 x 480 Vac | 2 A | 3 % @ 480 Vac | |
LR3 48-4/2 - no longer available | 3 x 480 Vac | 2 A | 4 % @ 480 Vac | |
LR3 48-5/2 | 3 x 480 Vac | 2 A | 5 % @ 480 Vac | |
LR3 48-3/4 | 3 x 480 Vac | 4 A | 3 % @ 480 Vac | |
LR3 48-4/4 - no longer available | 3 x 480 Vac | 4 A | 4 % @ 480 Vac | |
LR3 48-5/4 | 3 x 480 Vac | 4 A | 5 % @ 480 Vac | |
LR3 48-3/6 | 3 x 480 Vac | 6 A | 3 % @ 480 Vac | |
LR3 48-4/6 - no longer available | 3 x 480 Vac | 6 A | 4 % @ 480 Vac | |
LR3 48-5/6 | 3 x 480 Vac | 6 A | 5 % @ 480 Vac | |
LR3 48-3/8 | 3 x 480 Vac | 8 A | 3 % @ 480 Vac | |
LR3 48-4/8 - no longer available | 3 x 480 Vac | 8 A | 4 % @ 480 Vac | |
LR3 48-5/8 | 3 x 480 Vac | 8 A | 5 % @ 480 Vac | |
LR3 48-3/10 | 3 x 480 Vac | 10 A | 3 % @ 480 Vac | |
LR3 48-4/10 - no longer available | 3 x 480 Vac | 10 A | 4 % @ 480 Vac | |
LR3 48-5/10 | 3 x 480 Vac | 10 A | 5 % @ 480 Vac | |
LR3 48-3/16 | 3 x 480 Vac | 16 A | 3 % @ 480 Vac | |
LR3 48-4/16 - no longer available | 3 x 480 Vac | 16 A | 4 % @ 480 Vac | |
LR3 48-5/16 | 3 x 480 Vac | 16 A | 5 % @ 480 Vac | |
LR3 48-3/20 | 3 x 480 Vac | 20 A | 3 % @ 480 Vac | |
LR3 48-4/20 - no longer available | 3 x 480 Vac | 20 A | 4 % @ 480 Vac | |
LR3 48-5/20 | 3 x 480 Vac | 20 A | 5 % @ 480 Vac | |
LR3 48-3/25 | 3 x 480 Vac | 25 A | 3 % @ 480 Vac | |
LR3 48-4/25 - no longer available | 3 x 480 Vac | 25 A | 4 % @ 480 Vac | |
LR3 48-5/25 | 3 x 480 Vac | 25 A | 5 % @ 480 Vac | |
LR3 48-3/30 | 3 x 480 Vac | 30 A | 3 % @ 480 Vac | |
LR3 48-4/30 - no longer available | 3 x 480 Vac | 30 A | 4 % @ 480 Vac | |
LR3 48-5/30 | 3 x 480 Vac | 30 A | 5 % @ 480 Vac | |
LR3 48-3/35 | 3 x 480 Vac | 35 A | 3 % @ 480 Vac | |
LR3 48-4/35 - no longer available | 3 x 480 Vac | 35 A | 4 % @ 480 Vac | |
LR3 48-5/35 | 3 x 480 Vac | 35 A | 5 % @ 480 Vac | |
LR3 48-3/40 | 3 x 480 Vac | 40 A | 3 % @ 480 Vac | |
LR3 48-4/40 - no longer available | 3 x 480 Vac | 40 A | 4 % @ 480 Vac | |
LR3 48-5/40 | 3 x 480 Vac | 40 A | 5 % @ 480 Vac | |
LR3 48-3/45 | 3 x 480 Vac | 45 A | 3 % @ 480 Vac | |
LR3 48-4/45 - no longer available | 3 x 480 Vac | 45 A | 4 % @ 480 Vac | |
LR3 48-5/45 | 3 x 480 Vac | 45 A | 5 % @ 480 Vac | |
LR3 48-3/50 | 3 x 480 Vac | 50 A | 3 % @ 480 Vac | |
LR3 48-4/50 - no longer available | 3 x 480 Vac | 50 A | 4 % @ 480 Vac | |
LR3 48-5/50 | 3 x 480 Vac | 50 A | 5 % @ 480 Vac | |
LR3 48-3/63 | 3 x 480 Vac | 63 A | 3 % @ 480 Vac | |
LR3 48-4/63 - no longer available | 3 x 480 Vac | 63 A | 4 % @ 480 Vac | |
LR3 48-5/63 | 3 x 480 Vac | 63 A | 5 % @ 480 Vac | |
LR3 48-3/70 | 3 x 480 Vac | 70 A | 3 % @ 480 Vac | |
LR3 48-4/70 - no longer available | 3 x 480 Vac | 70 A | 4 % @ 480 Vac | |
LR3 48-5/70 | 3 x 480 Vac | 70 A | 5 % @ 480 Vac | |
LR3 48-3/80 | 3 x 480 Vac | 80 A | 3 % @ 480 Vac | |
LR3 48-4/80 - no longer available | 3 x 480 Vac | 80 A | 4 % @ 480 Vac | |
LR3 48-5/80 | 3 x 480 Vac | 80 A | 5 % @ 480 Vac | |
LR3 48-3/90 | 3 x 480 Vac | 90 A | 3 % @ 480 Vac | |
LR3 48-4/90 - no longer available | 3 x 480 Vac | 90 A | 4 % @ 480 Vac | |
LR3 48-5/90 | 3 x 480 Vac | 90 A | 5 % @ 480 Vac | |
LR3 48-3/100 | 3 x 480 Vac | 100 A | 3 % @ 480 Vac | |
LR3 48-4/100 - no longer available | 3 x 480 Vac | 100 A | 4 % @ 480 Vac | |
LR3 48-5/100 | 3 x 480 Vac | 100 A | 5 % @ 480 Vac | |
LR3 48-3/115 | 3 x 480 Vac | 115 A | 3 % @ 480 Vac | |
LR3 48-4/115 - no longer available | 3 x 480 Vac | 115 A | 4 % @ 480 Vac | |
LR3 48-5/115 | 3 x 480 Vac | 115 A | 5 % @ 480 Vac | |
LR3 48-3/125 | 3 x 480 Vac | 125 A | 3 % @ 480 Vac | |
LR3 48-4/125 - no longer available | 3 x 480 Vac | 125 A | 4 % @ 480 Vac | |
LR3 48-5/125 | 3 x 480 Vac | 125 A | 5 % @ 480 Vac | |
LR3 48-3/160 | 3 x 480 Vac | 160 A | 3 % @ 480 Vac | |
LR3 48-4/160 - no longer available | 3 x 480 Vac | 160 A | 4 % @ 480 Vac | |
LR3 48-5/160 | 3 x 480 Vac | 160 A | 5 % @ 480 Vac | |
LR3 48-3/180 | 3 x 480 Vac | 180 A | 3 % @ 480 Vac | |
LR3 48-4/180 - no longer available | 3 x 480 Vac | 180 A | 4 % @ 480 Vac | |
LR3 48-5/180 | 3 x 480 Vac | 180 A | 5 % @ 480 Vac | |
LR3 48-3/200 | 3 x 480 Vac | 200 A | 3 % @ 480 Vac | |
LR3 48-4/200 - no longer available | 3 x 480 Vac | 200 A | 4 % @ 480 Vac | |
LR3 48-5/200 | 3 x 480 Vac | 200 A | 5 % @ 480 Vac | |
LR3 48-3/250 | 3 x 480 Vac | 250 A | 3 % @ 480 Vac | |
LR3 48-4/250 - no longer available | 3 x 480 Vac | 250 A | 4 % @ 480 Vac | |
LR3 48-5/250 | 3 x 480 Vac | 250 A | 5 % @ 480 Vac | |
LR3 48-3/300 | 3 x 480 Vac | 300 A | 3 % @ 480 Vac | |
LR3 48-4/300 - no longer available | 3 x 480 Vac | 300 A | 4 % @ 480 Vac | |
LR3 48-5/300 | 3 x 480 Vac | 300 A | 5 % @ 480 Vac | |
LR3 48-3/400 | 3 x 480 Vac | 400 A | 3 % @ 480 Vac | |
LR3 48-4/400 - no longer available | 3 x 480 Vac | 400 A | 4 % @ 480 Vac | |
LR3 48-5/400 | 3 x 480 Vac | 400 A | 5 % @ 480 Vac | |
LR3 48-3/500 | 3 x 480 Vac | 500 A | 3 % @ 480 Vac | |
LR3 48-4/500 - no longer available | 3 x 480 Vac | 500 A | 4 % @ 480 Vac | |
LR3 48-5/500 | 3 x 480 Vac | 500 A | 5 % @ 480 Vac | |
LR3 48-3/630 | 3 x 480 Vac | 630 A | 3 % @ 480 Vac | |
LR3 48-4/630 - no longer available | 3 x 480 Vac | 630 A | 4 % @ 480 Vac | |
LR3 48-5/630 | 3 x 480 Vac | 630 A | 5 % @ 480 Vac | |
LR3 48-3/710 | 3 x 480 Vac | 710 A | 3 % @ 480 Vac | |
LR3 48-4/710 - no longer available | 3 x 480 Vac | 710 A | 4 % @ 480 Vac | |
LR3 48-5/710 | 3 x 480 Vac | 710 A | 5 % @ 480 Vac | |
LR3 48-3/800 | 3 x 480 Vac | 800 A | 3 % @ 480 Vac | |
LR3 48-4/800 - no longer available | 3 x 480 Vac | 800 A | 4 % @ 480 Vac | |
LR3 48-5/800 | 3 x 480 Vac | 800 A | 5 % @ 480 Vac | |
LR3 48-3/1000 | 3 x 480 Vac | 1000 A | 3 % @ 480 Vac | |
LR3 48-4/1000 - no longer available | 3 x 480 Vac | 1000 A | 4 % @ 480 Vac | |
LR3 48-5/1000 | 3 x 480 Vac | 1000 A | 5 % @ 480 Vac | |
LR3 48-3/1200 | 3 x 480 Vac | 1200 A | 3 % @ 480 Vac | |
LR3 48-4/1200 - no longer available | 3 x 480 Vac | 1200 A | 4 % @ 480 Vac | |
LR3 48-5/1200 | 3 x 480 Vac | 1200 A | 5 % @ 480 Vac | |
LR3 48-3/1400 | 3 x 480 Vac | 1400 A | 3 % @ 480 Vac | |
LR3 48-4/1400 - no longer available | 3 x 480 Vac | 1400 A | 4 % @ 480 Vac | |
LR3 48-5/1400 | 3 x 480 Vac | 1400 A | 5 % @ 480 Vac | |
LR3 48-3/1600 | 3 x 480 Vac | 1600 A | 3 % @ 480 Vac | |
LR3 48-4/1600 - no longer available | 3 x 480 Vac | 1600 A | 4 % @ 480 Vac | |
LR3 48-5/1600 | 3 x 480 Vac | 1600 A | 5 % @ 480 Vac |
DOWNLOADS
Technical files
Manual
Approvals / Manufacturer's declaration
EU-Declaration of Conformity
Additional information
LR3 brochure 480 V
Technical data for LR3 48-3/1000
Operating data | |
---|---|
Rated voltage | 3 x 480 Vac |
Short circuit voltage uK | 3 % @ 480 Vac |
Voltage drop | 8.3 Vac |
Rated current | 1000 A |
Rated frequency | 50 - 60 Hz |
Inductance | 0.022 mH |
Inductance deviation | ±10% |
Approvals | |
---|---|
Approvals | cURus, cULus |
Environment | |
---|---|
Ambient temperature | -10 °C to +40 °C |
Type of cooling | AN |
Safety and protection | |
---|---|
Type | Open type |
Insulation class | IEC=H, UL=class 180 |
Protection index | IP 00 |
Safety class (prepared) | I |
Test voltage | 4000 Vac |
Terminal and mounting | |
---|---|
Terminals phase | Flat copper |
Terminals PE | for M16 |
Fixing method | Fixing rail |
Fixing screws | M10 |
Measures and weights | |
---|---|
Width | 480 mm |
Height | 360 mm |
Depth | 198 mm |
Weight | 68.9 kg |
Info on LR3 480 series
General Data
- Rated current 3 x 2 - 3 x 1600 A
- Degree of protection IP 00
- Ambient temperature -10 °C to +40 °C
- Insulation class B, F or H
- Inductance 0.014 - 18.500 mH
- Short-circuit voltage (uK) 3 - 5 %
- Rated voltage 3 x 480 Vac
Benefits
- Bridging voltage dips
- Starting current limitation
- Use as line reactor, commutating reactor or PFC reactor
- Ensuring the short-circuit voltage of 3 - 5 % to the mains
- Power harmonic damping
- Low ripple
- Multifunctional fixing rails
- Peak current limitation
- Increases the service life of consumers
- Very good corrosion protection and low noise thanks to vacuum impregnation
- Integrated lifting rings