LR3 40-4/80

Line reactor LR3 400

Version LR3 40-4/80
Rated voltage 3 x 400 Vac Rated current 3 x 80 A Short circuit voltage uK 4 % @ 400 Vac
Version Rated voltage Rated current Short circuit voltage uK
LR3 40-3/2 3 x 400 Vac 3 x 2 A 3 % @ 400 Vac
LR3 40-4/2 3 x 400 Vac 3 x 2 A 4 % @ 400 Vac
LR3 40-5/2 3 x 400 Vac 3 x 2 A 5 % @ 400 Vac
LR3 40-3/4 3 x 400 Vac 3 x 4 A 3 % @ 400 Vac
LR3 40-4/4 3 x 400 Vac 3 x 4 A 4 % @ 400 Vac
LR3 40-5/4 3 x 400 Vac 3 x 4 A 5 % @ 400 Vac
LR3 40-3/6 3 x 400 Vac 3 x 6 A 3 % @ 400 Vac
LR3 40-4/6 3 x 400 Vac 3 x 6 A 4 % @ 400 Vac
LR3 40-5/6 3 x 400 Vac 3 x 6 A 5 % @ 400 Vac
LR3 40-3/8 3 x 400 Vac 3 x 8 A 3 % @ 400 Vac
LR3 40-4/8 3 x 400 Vac 3 x 8 A 4 % @ 400 Vac
LR3 40-5/8 3 x 400 Vac 3 x 8 A 5 % @ 400 Vac
LR3 40-3/10 3 x 400 Vac 3 x 10 A 3 % @ 400 Vac
LR3 40-4/10 3 x 400 Vac 3 x 10 A 4 % @ 400 Vac
LR3 40-5/10 3 x 400 Vac 3 x 10 A 5 % @ 400 Vac
LR3 40-3/16 3 x 400 Vac 3 x 16 A 3 % @ 400 Vac
LR3 40-4/16 3 x 400 Vac 3 x 16 A 4 % @ 400 Vac
LR3 40-5/16 3 x 400 Vac 3 x 16 A 5 % @ 400 Vac
LR3 40-3/20 3 x 400 Vac 3 x 20 A 3 % @ 400 Vac
LR3 40-4/20 3 x 400 Vac 3 x 20 A 4 % @ 400 Vac
LR3 40-5/20 3 x 400 Vac 3 x 20 A 5 % @ 400 Vac
LR3 40-3/25 3 x 400 Vac 3 x 25 A 3 % @ 400 Vac
LR3 40-4/25 3 x 400 Vac 3 x 25 A 4 % @ 400 Vac
LR3 40-5/25 3 x 400 Vac 3 x 25 A 5 % @ 400 Vac
LR3 40-3/30 3 x 400 Vac 3 x 30 A 3 % @ 400 Vac
LR3 40-4/30 3 x 400 Vac 3 x 30 A 4 % @ 400 Vac
LR3 40-5/30 3 x 400 Vac 3 x 30 A 5 % @ 400 Vac
LR3 40-3/35 3 x 400 Vac 3 x 35 A 3 % @ 400 Vac
LR3 40-4/35 3 x 400 Vac 3 x 35 A 4 % @ 400 Vac
LR3 40-5/35 3 x 400 Vac 3 x 35 A 5 % @ 400 Vac
LR3 40-3/40 3 x 400 Vac 3 x 40 A 3 % @ 400 Vac
LR3 40-4/40 3 x 400 Vac 3 x 40 A 4 % @ 400 Vac
LR3 40-5/40 3 x 400 Vac 3 x 40 A 5 % @ 400 Vac
LR3 40-3/45 3 x 400 Vac 3 x 45 A 3 % @ 400 Vac
LR3 40-4/45 3 x 400 Vac 3 x 45 A 4 % @ 400 Vac
LR3 40-5/45 3 x 400 Vac 3 x 45 A 5 % @ 400 Vac
LR3 40-3/50 3 x 400 Vac 3 x 50 A 3 % @ 400 Vac
LR3 40-4/50 3 x 400 Vac 3 x 50 A 4 % @ 400 Vac
LR3 40-5/50 3 x 400 Vac 3 x 50 A 5 % @ 400 Vac
LR3 40-3/63 3 x 400 Vac 3 x 63 A 3 % @ 400 Vac
LR3 40-4/63 3 x 400 Vac 3 x 63 A 4 % @ 400 Vac
LR3 40-5/63 3 x 400 Vac 3 x 63 A 5 % @ 400 Vac
LR3 40-3/70 3 x 400 Vac 3 x 70 A 3 % @ 400 Vac
LR3 40-4/70 3 x 400 Vac 3 x 70 A 4 % @ 400 Vac
LR3 40-5/70 3 x 400 Vac 3 x 70 A 5 % @ 400 Vac
LR3 40-3/80 3 x 400 Vac 3 x 80 A 3 % @ 400 Vac
LR3 40-4/80 3 x 400 Vac 3 x 80 A 4 % @ 400 Vac
LR3 40-5/80 3 x 400 Vac 3 x 80 A 5 % @ 400 Vac
LR3 40-3/90 3 x 400 Vac 3 x 90 A 3 % @ 400 Vac
LR3 40-4/90 3 x 400 Vac 3 x 90 A 4 % @ 400 Vac
LR3 40-5/90 3 x 400 Vac 3 x 90 A 5 % @ 400 Vac
LR3 40-3/100 3 x 400 Vac 3 x 100 A 3 % @ 400 Vac
LR3 40-4/100 3 x 400 Vac 3 x 100 A 4 % @ 400 Vac
LR3 40-5/100 3 x 400 Vac 3 x 100 A 5 % @ 400 Vac
LR3 40-3/115 3 x 400 Vac 3 x 115 A 3 % @ 400 Vac
LR3 40-4/115 3 x 400 Vac 3 x 115 A 4 % @ 400 Vac
LR3 40-5/115 3 x 400 Vac 3 x 115 A 5 % @ 400 Vac
LR3 40-3/125 3 x 400 Vac 3 x 125 A 3 % @ 400 Vac
LR3 40-4/125 3 x 400 Vac 3 x 125 A 4 % @ 400 Vac
LR3 40-5/125 3 x 400 Vac 3 x 125 A 5 % @ 400 Vac
LR3 40-3/160 3 x 400 Vac 3 x 160 A 3 % @ 400 Vac
LR3 40-4/160 3 x 400 Vac 3 x 160 A 4 % @ 400 Vac
LR3 40-5/160 3 x 400 Vac 3 x 160 A 5 % @ 400 Vac
LR3 40-3/180 3 x 400 Vac 3 x 180 A 3 % @ 400 Vac
LR3 40-4/180 3 x 400 Vac 3 x 180 A 4 % @ 400 Vac
LR3 40-5/180 3 x 400 Vac 3 x 180 A 5 % @ 400 Vac
LR3 40-3/200 3 x 400 Vac 3 x 200 A 3 % @ 400 Vac
LR3 40-4/200 3 x 400 Vac 3 x 200 A 4 % @ 400 Vac
LR3 40-5/200 3 x 400 Vac 3 x 200 A 5 % @ 400 Vac
LR3 40-3/250 3 x 400 Vac 3 x 250 A 3 % @ 400 Vac
LR3 40-4/250 3 x 400 Vac 3 x 250 A 4 % @ 400 Vac
LR3 40-5/250 3 x 400 Vac 3 x 250 A 5 % @ 400 Vac
LR3 40-3/300 3 x 400 Vac 3 x 300 A 3 % @ 400 Vac
LR3 40-4/300 3 x 400 Vac 3 x 300 A 4 % @ 400 Vac
LR3 40-5/300 3 x 400 Vac 3 x 300 A 5 % @ 400 Vac
LR3 40-3/400 3 x 400 Vac 3 x 400 A 3 % @ 400 Vac
LR3 40-4/400 3 x 400 Vac 3 x 400 A 4 % @ 400 Vac
LR3 40-5/400 3 x 400 Vac 3 x 400 A 5 % @ 400 Vac
LR3 40-3/500 3 x 400 Vac 3 x 500 A 3 % @ 400 Vac
LR3 40-4/500 3 x 400 Vac 3 x 500 A 4 % @ 400 Vac
LR3 40-5/500 3 x 400 Vac 3 x 500 A 5 % @ 400 Vac
LR3 40-3/630 3 x 400 Vac 3 x 630 A 3 % @ 400 Vac
LR3 40-4/630 3 x 400 Vac 3 x 630 A 4 % @ 400 Vac
LR3 40-5/630 3 x 400 Vac 3 x 630 A 5 % @ 400 Vac
LR3 40-3/710 3 x 400 Vac 3 x 710 A 3 % @ 400 Vac
LR3 40-4/710 3 x 400 Vac 3 x 710 A 4 % @ 400 Vac
LR3 40-5/710 3 x 400 Vac 3 x 710 A 5 % @ 400 Vac
LR3 40-3/800 3 x 400 Vac 3 x 800 A 3 % @ 400 Vac
LR3 40-4/800 3 x 400 Vac 3 x 800 A 4 % @ 400 Vac
LR3 40-5/800 3 x 400 Vac 3 x 800 A 5 % @ 400 Vac
LR3 40-3/1000 3 x 400 Vac 3 x 1000 A 3 % @ 400 Vac
LR3 40-4/1000 3 x 400 Vac 3 x 1000 A 4 % @ 400 Vac
LR3 40-5/1000 3 x 400 Vac 3 x 1000 A 5 % @ 400 Vac
LR3 40-3/1200 3 x 400 Vac 3 x 1200 A 3 % @ 400 Vac
LR3 40-4/1200 3 x 400 Vac 3 x 1200 A 4 % @ 400 Vac
LR3 40-5/1200 3 x 400 Vac 3 x 1200 A 5 % @ 400 Vac
LR3 40-3/1400 3 x 400 Vac 3 x 1400 A 3 % @ 400 Vac
LR3 40-4/1400 3 x 400 Vac 3 x 1400 A 4 % @ 400 Vac
LR3 40-5/1400 3 x 400 Vac 3 x 1400 A 5 % @ 400 Vac
LR3 40-3/1600 3 x 400 Vac 3 x 1600 A 3 % @ 400 Vac
LR3 40-4/1600 3 x 400 Vac 3 x 1600 A 4 % @ 400 Vac
LR3 40-5/1600 3 x 400 Vac 3 x 1600 A 5 % @ 400 Vac
Image of %s BLOCK Item: LR3 40-4/80
Technical files Data sheet Approvals / Manufacturer's declaration EU-Declaration of Conformity CAD/CAE data 3D-CAD-Model (STEP) ePlan Makro

Technical data for LR3 40-4/80

Operating data
Rated voltage 3 x 400 Vac
Rated voltage (IEC) 3 x 690 Vac
Rated voltage (UL) 3 x 600 Vac
Short circuit voltage uK 4 % @ 400 Vac
Voltage drop 9.2 Vac
Rated current 3 x 80 A
Rated frequency 50 - 60 Hz
Inductance 0.370 mH
Inductance deviation ±10%
Output
Power loss 230.4 W
Approvals
Approvals cURus
Environment
Ambient temperature -10 °C to +40 °C
Type of cooling AN
Safety and protection
Type Open type
Insulation class IEC=F, UL=class 155
Protection index IP 00
Safety class (prepared) I
Test voltage 4000 Vac
Terminal and mounting
Terminals phase Screw clamp, 35 mm²
Terminals PE for M5
Fixing method Fixing rail
Fixing screws M6
Measures and weights
Width 210 mm
Height 238 mm
Depth 125 mm
Weight 12.50 kg

Info on LR3 400 series

General Data
  • Rated current 3 x 2 - 3 x 1600 A
  • Ambient temperature -10 °C to +40 °C
  • Insulation class B, F or H
  • Inductance 0.019 - 18.500 mH
  • Short-circuit voltage (uK) 3 - 5 %
  • Rated voltage 3 x 400 Vac
  • Degree of protection IP 00
Benefits
  • Power harmonic damping
  • Ensuring the short-circuit voltage of 3, 4 or 5 % to the mains
  • Low ripple
  • Bridging voltage dips
  • Increases the service life of consumers
  • Starting current limitation
  • Use as line reactor, commutating reactor or PFC reactor
  • Peak current limitation
  • Very good corrosion protection and low noise thanks to vacuum impregnation
  • Integrated lifting rings
  • Multifunctional fixing rails

Our recommendations for you

BLOCK product: LR3-AD080-404-0
LR3-AD080-404-0
Line reactor, three-phase
3 x 400 Vac, 3 x 4 - 3 x 900 A, 7,350 – 0,024 mH, Use as line reactor, commutating reactor or PFC reactor
to accessory part
BLOCK product: HLD 110-500/75
HLD 110-500/75
Radio interference suppression filter, three-phase
3 x 520 Vac, 3 x 8 – 3 x 250 A, Leakage current 20.00 - 37.00 mA, For enhanced requirements
to accessory part
BLOCK product: HF1K 70-400
HF1K 70-400
Harmonic filter
3 x 400 Vac, 3 x 10 – 3 x 144 A , 5.5 – 90 kW, Cos(phi)>0,95 at rated current