LR3 40-3/25

Line reactor LR3 400

Version LR3 40-3/25
Rated voltage 3 x 400 Vac Rated current 3 x 25 A Short circuit voltage uK 3 % @ 400 Vac
Version Rated voltage Rated current Short circuit voltage uK
LR3 40-3/2 3 x 400 Vac 3 x 2 A 3 % @ 400 Vac
LR3 40-4/2 3 x 400 Vac 3 x 2 A 4 % @ 400 Vac
LR3 40-5/2 3 x 400 Vac 3 x 2 A 5 % @ 400 Vac
LR3 40-3/4 3 x 400 Vac 3 x 4 A 3 % @ 400 Vac
LR3 40-4/4 3 x 400 Vac 3 x 4 A 4 % @ 400 Vac
LR3 40-5/4 3 x 400 Vac 3 x 4 A 5 % @ 400 Vac
LR3 40-3/6 3 x 400 Vac 3 x 6 A 3 % @ 400 Vac
LR3 40-4/6 3 x 400 Vac 3 x 6 A 4 % @ 400 Vac
LR3 40-5/6 3 x 400 Vac 3 x 6 A 5 % @ 400 Vac
LR3 40-3/8 3 x 400 Vac 3 x 8 A 3 % @ 400 Vac
LR3 40-4/8 3 x 400 Vac 3 x 8 A 4 % @ 400 Vac
LR3 40-5/8 3 x 400 Vac 3 x 8 A 5 % @ 400 Vac
LR3 40-3/10 3 x 400 Vac 3 x 10 A 3 % @ 400 Vac
LR3 40-4/10 3 x 400 Vac 3 x 10 A 4 % @ 400 Vac
LR3 40-5/10 3 x 400 Vac 3 x 10 A 5 % @ 400 Vac
LR3 40-3/16 3 x 400 Vac 3 x 16 A 3 % @ 400 Vac
LR3 40-4/16 3 x 400 Vac 3 x 16 A 4 % @ 400 Vac
LR3 40-5/16 3 x 400 Vac 3 x 16 A 5 % @ 400 Vac
LR3 40-3/20 3 x 400 Vac 3 x 20 A 3 % @ 400 Vac
LR3 40-4/20 3 x 400 Vac 3 x 20 A 4 % @ 400 Vac
LR3 40-5/20 3 x 400 Vac 3 x 20 A 5 % @ 400 Vac
LR3 40-3/25 3 x 400 Vac 3 x 25 A 3 % @ 400 Vac
LR3 40-4/25 3 x 400 Vac 3 x 25 A 4 % @ 400 Vac
LR3 40-5/25 3 x 400 Vac 3 x 25 A 5 % @ 400 Vac
LR3 40-3/30 3 x 400 Vac 3 x 30 A 3 % @ 400 Vac
LR3 40-4/30 3 x 400 Vac 3 x 30 A 4 % @ 400 Vac
LR3 40-5/30 3 x 400 Vac 3 x 30 A 5 % @ 400 Vac
LR3 40-3/35 3 x 400 Vac 3 x 35 A 3 % @ 400 Vac
LR3 40-4/35 3 x 400 Vac 3 x 35 A 4 % @ 400 Vac
LR3 40-5/35 3 x 400 Vac 3 x 35 A 5 % @ 400 Vac
LR3 40-3/40 3 x 400 Vac 3 x 40 A 3 % @ 400 Vac
LR3 40-4/40 3 x 400 Vac 3 x 40 A 4 % @ 400 Vac
LR3 40-5/40 3 x 400 Vac 3 x 40 A 5 % @ 400 Vac
LR3 40-3/45 3 x 400 Vac 3 x 45 A 3 % @ 400 Vac
LR3 40-4/45 3 x 400 Vac 3 x 45 A 4 % @ 400 Vac
LR3 40-5/45 3 x 400 Vac 3 x 45 A 5 % @ 400 Vac
LR3 40-3/50 3 x 400 Vac 3 x 50 A 3 % @ 400 Vac
LR3 40-4/50 3 x 400 Vac 3 x 50 A 4 % @ 400 Vac
LR3 40-5/50 3 x 400 Vac 3 x 50 A 5 % @ 400 Vac
LR3 40-3/63 3 x 400 Vac 3 x 63 A 3 % @ 400 Vac
LR3 40-4/63 3 x 400 Vac 3 x 63 A 4 % @ 400 Vac
LR3 40-5/63 3 x 400 Vac 3 x 63 A 5 % @ 400 Vac
LR3 40-3/70 3 x 400 Vac 3 x 70 A 3 % @ 400 Vac
LR3 40-4/70 3 x 400 Vac 3 x 70 A 4 % @ 400 Vac
LR3 40-5/70 3 x 400 Vac 3 x 70 A 5 % @ 400 Vac
LR3 40-3/80 3 x 400 Vac 3 x 80 A 3 % @ 400 Vac
LR3 40-4/80 3 x 400 Vac 3 x 80 A 4 % @ 400 Vac
LR3 40-5/80 3 x 400 Vac 3 x 80 A 5 % @ 400 Vac
LR3 40-3/90 3 x 400 Vac 3 x 90 A 3 % @ 400 Vac
LR3 40-4/90 3 x 400 Vac 3 x 90 A 4 % @ 400 Vac
LR3 40-5/90 3 x 400 Vac 3 x 90 A 5 % @ 400 Vac
LR3 40-3/100 3 x 400 Vac 3 x 100 A 3 % @ 400 Vac
LR3 40-4/100 3 x 400 Vac 3 x 100 A 4 % @ 400 Vac
LR3 40-5/100 3 x 400 Vac 3 x 100 A 5 % @ 400 Vac
LR3 40-3/115 3 x 400 Vac 3 x 115 A 3 % @ 400 Vac
LR3 40-4/115 3 x 400 Vac 3 x 115 A 4 % @ 400 Vac
LR3 40-5/115 3 x 400 Vac 3 x 115 A 5 % @ 400 Vac
LR3 40-3/125 3 x 400 Vac 3 x 125 A 3 % @ 400 Vac
LR3 40-4/125 3 x 400 Vac 3 x 125 A 4 % @ 400 Vac
LR3 40-5/125 3 x 400 Vac 3 x 125 A 5 % @ 400 Vac
LR3 40-3/160 3 x 400 Vac 3 x 160 A 3 % @ 400 Vac
LR3 40-4/160 3 x 400 Vac 3 x 160 A 4 % @ 400 Vac
LR3 40-5/160 3 x 400 Vac 3 x 160 A 5 % @ 400 Vac
LR3 40-3/180 3 x 400 Vac 3 x 180 A 3 % @ 400 Vac
LR3 40-4/180 3 x 400 Vac 3 x 180 A 4 % @ 400 Vac
LR3 40-5/180 3 x 400 Vac 3 x 180 A 5 % @ 400 Vac
LR3 40-3/200 3 x 400 Vac 3 x 200 A 3 % @ 400 Vac
LR3 40-4/200 3 x 400 Vac 3 x 200 A 4 % @ 400 Vac
LR3 40-5/200 3 x 400 Vac 3 x 200 A 5 % @ 400 Vac
LR3 40-3/250 3 x 400 Vac 3 x 250 A 3 % @ 400 Vac
LR3 40-4/250 3 x 400 Vac 3 x 250 A 4 % @ 400 Vac
LR3 40-5/250 3 x 400 Vac 3 x 250 A 5 % @ 400 Vac
LR3 40-3/300 3 x 400 Vac 3 x 300 A 3 % @ 400 Vac
LR3 40-4/300 3 x 400 Vac 3 x 300 A 4 % @ 400 Vac
LR3 40-5/300 3 x 400 Vac 3 x 300 A 5 % @ 400 Vac
LR3 40-3/400 3 x 400 Vac 3 x 400 A 3 % @ 400 Vac
LR3 40-4/400 3 x 400 Vac 3 x 400 A 4 % @ 400 Vac
LR3 40-5/400 3 x 400 Vac 3 x 400 A 5 % @ 400 Vac
LR3 40-3/500 3 x 400 Vac 3 x 500 A 3 % @ 400 Vac
LR3 40-4/500 3 x 400 Vac 3 x 500 A 4 % @ 400 Vac
LR3 40-5/500 3 x 400 Vac 3 x 500 A 5 % @ 400 Vac
LR3 40-3/630 3 x 400 Vac 3 x 630 A 3 % @ 400 Vac
LR3 40-4/630 3 x 400 Vac 3 x 630 A 4 % @ 400 Vac
LR3 40-5/630 3 x 400 Vac 3 x 630 A 5 % @ 400 Vac
LR3 40-3/710 3 x 400 Vac 3 x 710 A 3 % @ 400 Vac
LR3 40-4/710 3 x 400 Vac 3 x 710 A 4 % @ 400 Vac
LR3 40-5/710 3 x 400 Vac 3 x 710 A 5 % @ 400 Vac
LR3 40-3/800 3 x 400 Vac 3 x 800 A 3 % @ 400 Vac
LR3 40-4/800 3 x 400 Vac 3 x 800 A 4 % @ 400 Vac
LR3 40-5/800 3 x 400 Vac 3 x 800 A 5 % @ 400 Vac
LR3 40-3/1000 3 x 400 Vac 3 x 1000 A 3 % @ 400 Vac
LR3 40-4/1000 3 x 400 Vac 3 x 1000 A 4 % @ 400 Vac
LR3 40-5/1000 3 x 400 Vac 3 x 1000 A 5 % @ 400 Vac
LR3 40-3/1200 3 x 400 Vac 3 x 1200 A 3 % @ 400 Vac
LR3 40-4/1200 3 x 400 Vac 3 x 1200 A 4 % @ 400 Vac
LR3 40-5/1200 3 x 400 Vac 3 x 1200 A 5 % @ 400 Vac
LR3 40-3/1400 3 x 400 Vac 3 x 1400 A 3 % @ 400 Vac
LR3 40-4/1400 3 x 400 Vac 3 x 1400 A 4 % @ 400 Vac
LR3 40-5/1400 3 x 400 Vac 3 x 1400 A 5 % @ 400 Vac
LR3 40-3/1600 3 x 400 Vac 3 x 1600 A 3 % @ 400 Vac
LR3 40-4/1600 3 x 400 Vac 3 x 1600 A 4 % @ 400 Vac
LR3 40-5/1600 3 x 400 Vac 3 x 1600 A 5 % @ 400 Vac
Image of %s BLOCK Item: LR3 40-3/25

Technical data for LR3 40-3/25

Operating data
Rated voltage 3 x 400 Vac
Rated voltage (IEC) 3 x 690 Vac
Rated voltage (UL) 3 x 600 Vac
Short circuit voltage uK 3 % @ 400 Vac
Voltage drop 6.9 Vac
Rated current 3 x 25 A
Rated frequency 50 - 60 Hz
Inductance 0.880 mH
Inductance deviation ±10%
Output
Power loss 60.5 W
Approvals
Approvals cURus
Environment
Ambient temperature -10 °C to +40 °C
Type of cooling AN
Safety and protection
Type Open type
Insulation class IEC=F, UL=class 155
Protection index IP 00
Safety class (prepared) I
Test voltage 4000 Vac
Terminal and mounting
Terminals phase Screw clamp, 10 mm²
Terminals PE for M5
Fixing method Fixing rail
Fixing screws M5
Measures and weights
Width 155 mm
Height 177 mm
Depth 95 mm
Weight 3.80 kg

Info on LR3 400 series

General Data
  • Degree of protection IP 00
  • Rated voltage 3 x 400 Vac
  • Short-circuit voltage (uK) 3 - 5 %
  • Rated current 3 x 2 - 3 x 1600 A
  • Inductance 0.019 - 18.500 mH
  • Insulation class B, F or H
  • Ambient temperature -10 °C to +40 °C
Benefits
  • Ensuring the short-circuit voltage of 3, 4 or 5 % to the mains
  • Increases the service life of consumers
  • Low ripple
  • Starting current limitation
  • Power harmonic damping
  • Use as line reactor, commutating reactor or PFC reactor
  • Integrated lifting rings
  • Bridging voltage dips
  • Peak current limitation
  • Multifunctional fixing rails
  • Very good corrosion protection and low noise thanks to vacuum impregnation

Our recommendations for you

BLOCK product: HF1K 18-400
HF1K 18-400
Harmonic filter
3 x 400 Vac, 3 x 10 – 3 x 144 A , 5.5 – 90 kW, Cos(phi)>0,95 at rated current
to accessory part
BLOCK product: LR3-AD025-404-0
LR3-AD025-404-0
Line reactor, three-phase
3 x 400 Vac, 3 x 4 - 3 x 80 A, 7,350 – 0,370 mH, Use as line reactor, commutating reactor or PFC reactor
to accessory part
BLOCK product: HLD 110-500/30
HLD 110-500/30
Radio interference suppression filter, three-phase
3 x 520 Vac, 3 x 8 – 3 x 250 A, Leakage current 20.00 - 37.00 mA, For enhanced requirements