HLD 310-500/130
Radio interference suppression filter HLD 310
Rated voltage
3 x 520 Vac
Rated current
3 x 130 A
Leakage current (50 Hz)*
<0.40 mA
Version | Rated voltage | Rated current | Leakage current (50 Hz)* | |
---|---|---|---|---|
HLD 310-500/8 | 3 x 520 Vac | 3 x 8 A | <0.40 mA | |
HLD 310-500/12 | 3 x 520 Vac | 3 x 12 A | <0.40 mA | |
HLD 310-500/16 | 3 x 520 Vac | 3 x 16 A | <0.40 mA | |
HLD 310-500/30 | 3 x 520 Vac | 3 x 30 A | <0.40 mA | |
HLD 310-500/42 | 3 x 520 Vac | 3 x 42 A | <0.40 mA | |
HLD 310-500/55 | 3 x 520 Vac | 3 x 55 A | <0.40 mA | |
HLD 310-500/75 | 3 x 520 Vac | 3 x 75 A | <0.40 mA | |
HLD 310-500/100 | 3 x 520 Vac | 3 x 100 A | <0.40 mA | |
HLD 310-500/130 | 3 x 520 Vac | 3 x 130 A | <0.40 mA | |
HLD 310-500/180 | 3 x 520 Vac | 3 x 180 A | <0.40 mA | |
HLD 310-500/250 | 3 x 520 Vac | 3 x 250 A | <0.40 mA |
DOWNLOADS
Technical files
Data sheet
Approvals / Manufacturer's declaration
Manufacturer's declaration to EN 60939-2
COA UL 1283 & CSA 22.2
COC UL 1283 & CSA 22.2
CAD/CAE data
3D-CAD-Model (STEP)
ePlan Makro
Technical data for HLD 310-500/130
Special features | |
---|---|
Characteristics | Suitable for the medical field |
Operating data | |
---|---|
Rated voltage | 3 x 520 Vac |
Voltage range | 0 - 3 x 520 Vac |
Rated current | 3 x 130 A |
Leakage current (50 Hz)* | <0.40 mA |
Leakage current (50 Hz)** | <3.50 mA |
Power loss | 90.0 W |
Overrating Capacity | 150 %, shortly |
Input | |
---|---|
Rated frequency | 50 - 60 Hz |
Approvals | |
---|---|
Approvals | cURus, UL 1283 5th edition, CSA 22.2 No.8 |
Environment | |
---|---|
Ambient temperature max. | 50 °C |
Climatic category | 25/085/21 [in accordance with EN 60068-1] |
Safety and protection | |
---|---|
SCCR*** | 100 kA |
Protection index | IP 20 |
Type | Metal enclosure |
Safety class (prepared) | I |
Test voltage | 2150 Vdc Phase/Phase, 2700 Vdc Phase/PE |
Terminal and mounting | |
---|---|
Terminals phase | Screw clamp, 50 mm² |
Terminals PE | Bolt, M10 |
Fixing method | Mounting lugs |
Fixing screws | M6 |
Measures and weights | |
---|---|
Width | 95 mm |
Height | 150 mm |
Depth | 270 mm |
Weight | 5.60 kg |
Notes | |
---|---|
* | Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 % |
** | Leakage current by loss of two phases |
*** | with corresponding preliminary fuse |
Info on HLD 310 series
General Data
- Rated current 3 x 8 - 3 x 250 A
- Degree of protection IP 20
- Leakage current <0.4 mA
- Voltage range 0 - 3 x 520 Vac
- Rated voltage 3 x 520 Vac
Benefits
- Efficient filter effect against line-bound interference emissions
- For enhanced requirements
- Increase in the interference immunity of the connected consumer
- Low leakage current
- Single-stage filter concept