EB-0748-100-0
单通道断路器 EasyB
变体 EB-0748-100-0
输入额定电压
48 Vdc
输出额定电流
0,5A, 1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A
变体 | 输入额定电压 | 输出额定电流 | ||
---|---|---|---|---|
EB-2724-010-0 | 24 Vdc | 1 A | ||
EB-2724-010-4 | 24 Vdc | 1 A | ||
EB-2724-020-0 | 24 Vdc | 2 A | ||
EB-2724-020-4 | 24 Vdc | 2 A | ||
EB-2724-030-0 | 24 Vdc | 3 A | ||
EB-2724-030-4 | 24 Vdc | 3 A | ||
EB-2724-040-0 | 24 Vdc | 4 A | ||
EB-2724-040-4 | 24 Vdc | 4 A | ||
EB-2724-060-0 | 24 Vdc | 6 A | ||
EB-2724-060-4 | 24 Vdc | 6 A | ||
EB-2724-080-0 | 24 Vdc | 8 A | ||
EB-2724-080-4 | 24 Vdc | 8 A | ||
EB-2724-100-0 | 24 Vdc | 10 A | ||
EB-2724-100-4 | 24 Vdc | 10 A | ||
EB-0748-100-0 | 48 Vdc | 0,5A, 1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A | ||
EB-1748-060-0 | 48 Vdc | 6 A | ||
EB-1748-100-0 | 48 Vdc | 10 A |
的技术参数 EB-0748-100-0
输入 | |
---|---|
输入额定电压 | 48 Vdc |
供给输入电压的最大余波/脉动 | 3 % |
输入电压范围 | 32 - 58 Vdc |
模块最大持续电流 | 10 A |
每个端子极最大持续电流 | 10 A (-), 40 A (+) |
接通输出端的必要输入电压 | 17,5 Vdc (关断阈值 16,7 Vdc ), ± 0.7 Vdc |
过压保护 | 抑制二极管 33 Vdc |
输出 | |
---|---|
输出额定电压 | 48 Vdc |
输出关断后的等待时间(热释放) | 500 ms (短路) ... 5 s (过载) |
每通道最大负载电容量 | 10 - 40 mF |
输出并联 | 未许可 |
输出串接 | 未许可 |
电源恢复强度 最大 | 35 Vdc |
输出额定电流 | 0,5A, 1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A |
有效度 | 99.0 % |
信号装置 | |
---|---|
状态显示 | LED(红色,绿色,黄色)绿色: 通道打开 绿色闪烁: 过电流(>90%)红色: 通道关闭 红色闪烁: 通道关闭 热释放 黄色闪烁: 触发和热释放 |
信号输出 | 起始状态,防短路 DC 24 V,最大25 mA high = 故障, low = 通道关闭 |
许可 | |
---|---|
许可 | cURus, cULus, DNV GL |
环保 | |
---|---|
冷却方法 | 自然循环 |
环境温度 | -13 °F … +131 °F |
仓库温度 | -25 °C … +85 °C |
相对湿度 | 5 … 96 %, 摄氏度 无冷凝 |
必要最小间隔(侧面) | 0 mm |
必要最小间隔(上/下) | 30 mm |
安全性 和 防护等级 | |
---|---|
防护等级 | IP 20 |
防护等级 | III, 无 PE- 接口 |
脏污度 | 2 |
接口 和 安装 | |
---|---|
输入接口,(弹性端子) | 最大 16 mm² |
输出接口,(弹性端子) | 最大 2,5 mm² (2 x "+") |
信号装置接口,(弹性端子) | 最大 2,5 mm² |
安装位置 | DIN TS35 标准轨 水平 |
尺寸 和 重量 | |
---|---|
宽度 | 12 mm |
高度 | 99 mm |
深度 | 60 mm |
重量 | 0.039 kg |