LR3 40-3/250

Inductance de ligne LR3 400

Variante LR3 40-3/250
Tension nominale 3 x 400 V CA Courant nominale 3 x 250 A Tension de court-circuit uK 3 % @ 400 V CA
Variante Tension nominale Courant nominale Tension de court-circuit uK
LR3 40-3/2 3 x 400 V CA 3 x 2 A 3 % @ 400 V CA
LR3 40-4/2 3 x 400 V CA 3 x 2 A 4 % @ 400 V CA
LR3 40-5/2 3 x 400 V CA 3 x 2 A 5 % @ 400 V CA
LR3 40-3/4 3 x 400 V CA 3 x 4 A 3 % @ 400 V CA
LR3 40-4/4 3 x 400 V CA 3 x 4 A 4 % @ 400 V CA
LR3 40-5/4 3 x 400 V CA 3 x 4 A 5 % @ 400 V CA
LR3 40-3/6 3 x 400 V CA 3 x 6 A 3 % @ 400 V CA
LR3 40-4/6 3 x 400 V CA 3 x 6 A 4 % @ 400 V CA
LR3 40-5/6 3 x 400 V CA 3 x 6 A 5 % @ 400 V CA
LR3 40-3/8 3 x 400 V CA 3 x 8 A 3 % @ 400 V CA
LR3 40-4/8 3 x 400 V CA 3 x 8 A 4 % @ 400 V CA
LR3 40-5/8 3 x 400 V CA 3 x 8 A 5 % @ 400 V CA
LR3 40-3/10 3 x 400 V CA 3 x 10 A 3 % @ 400 V CA
LR3 40-4/10 3 x 400 V CA 3 x 10 A 4 % @ 400 V CA
LR3 40-5/10 3 x 400 V CA 3 x 10 A 5 % @ 400 V CA
LR3 40-3/16 3 x 400 V CA 3 x 16 A 3 % @ 400 V CA
LR3 40-4/16 3 x 400 V CA 3 x 16 A 4 % @ 400 V CA
LR3 40-5/16 3 x 400 V CA 3 x 16 A 5 % @ 400 V CA
LR3 40-3/20 3 x 400 V CA 3 x 20 A 3 % @ 400 V CA
LR3 40-4/20 3 x 400 V CA 3 x 20 A 4 % @ 400 V CA
LR3 40-5/20 3 x 400 V CA 3 x 20 A 5 % @ 400 V CA
LR3 40-3/25 3 x 400 V CA 3 x 25 A 3 % @ 400 V CA
LR3 40-4/25 3 x 400 V CA 3 x 25 A 4 % @ 400 V CA
LR3 40-5/25 3 x 400 V CA 3 x 25 A 5 % @ 400 V CA
LR3 40-3/30 3 x 400 V CA 3 x 30 A 3 % @ 400 V CA
LR3 40-4/30 3 x 400 V CA 3 x 30 A 4 % @ 400 V CA
LR3 40-5/30 3 x 400 V CA 3 x 30 A 5 % @ 400 V CA
LR3 40-3/35 3 x 400 V CA 3 x 35 A 3 % @ 400 V CA
LR3 40-4/35 3 x 400 V CA 3 x 35 A 4 % @ 400 V CA
LR3 40-5/35 3 x 400 V CA 3 x 35 A 5 % @ 400 V CA
LR3 40-3/40 3 x 400 V CA 3 x 40 A 3 % @ 400 V CA
LR3 40-4/40 3 x 400 V CA 3 x 40 A 4 % @ 400 V CA
LR3 40-5/40 3 x 400 V CA 3 x 40 A 5 % @ 400 V CA
LR3 40-3/45 3 x 400 V CA 3 x 45 A 3 % @ 400 V CA
LR3 40-4/45 3 x 400 V CA 3 x 45 A 4 % @ 400 V CA
LR3 40-5/45 3 x 400 V CA 3 x 45 A 5 % @ 400 V CA
LR3 40-3/50 3 x 400 V CA 3 x 50 A 3 % @ 400 V CA
LR3 40-4/50 3 x 400 V CA 3 x 50 A 4 % @ 400 V CA
LR3 40-5/50 3 x 400 V CA 3 x 50 A 5 % @ 400 V CA
LR3 40-3/63 3 x 400 V CA 3 x 63 A 3 % @ 400 V CA
LR3 40-4/63 3 x 400 V CA 3 x 63 A 4 % @ 400 V CA
LR3 40-5/63 3 x 400 V CA 3 x 63 A 5 % @ 400 V CA
LR3 40-3/70 3 x 400 V CA 3 x 70 A 3 % @ 400 V CA
LR3 40-4/70 3 x 400 V CA 3 x 70 A 4 % @ 400 V CA
LR3 40-5/70 3 x 400 V CA 3 x 70 A 5 % @ 400 V CA
LR3 40-3/80 3 x 400 V CA 3 x 80 A 3 % @ 400 V CA
LR3 40-4/80 3 x 400 V CA 3 x 80 A 4 % @ 400 V CA
LR3 40-5/80 3 x 400 V CA 3 x 80 A 5 % @ 400 V CA
LR3 40-3/90 3 x 400 V CA 3 x 90 A 3 % @ 400 V CA
LR3 40-4/90 3 x 400 V CA 3 x 90 A 4 % @ 400 V CA
LR3 40-5/90 3 x 400 V CA 3 x 90 A 5 % @ 400 V CA
LR3 40-3/100 3 x 400 V CA 3 x 100 A 3 % @ 400 V CA
LR3 40-4/100 3 x 400 V CA 3 x 100 A 4 % @ 400 V CA
LR3 40-5/100 3 x 400 V CA 3 x 100 A 5 % @ 400 V CA
LR3 40-3/115 3 x 400 V CA 3 x 115 A 3 % @ 400 V CA
LR3 40-4/115 3 x 400 V CA 3 x 115 A 4 % @ 400 V CA
LR3 40-5/115 3 x 400 V CA 3 x 115 A 5 % @ 400 V CA
LR3 40-3/125 3 x 400 V CA 3 x 125 A 3 % @ 400 V CA
LR3 40-4/125 3 x 400 V CA 3 x 125 A 4 % @ 400 V CA
LR3 40-5/125 3 x 400 V CA 3 x 125 A 5 % @ 400 V CA
LR3 40-3/160 3 x 400 V CA 3 x 160 A 3 % @ 400 V CA
LR3 40-4/160 3 x 400 V CA 3 x 160 A 4 % @ 400 V CA
LR3 40-5/160 3 x 400 V CA 3 x 160 A 5 % @ 400 V CA
LR3 40-3/180 3 x 400 V CA 3 x 180 A 3 % @ 400 V CA
LR3 40-4/180 3 x 400 V CA 3 x 180 A 4 % @ 400 V CA
LR3 40-5/180 3 x 400 V CA 3 x 180 A 5 % @ 400 V CA
LR3 40-3/200 3 x 400 V CA 3 x 200 A 3 % @ 400 V CA
LR3 40-4/200 3 x 400 V CA 3 x 200 A 4 % @ 400 V CA
LR3 40-5/200 3 x 400 V CA 3 x 200 A 5 % @ 400 V CA
LR3 40-3/250 3 x 400 V CA 3 x 250 A 3 % @ 400 V CA
LR3 40-4/250 3 x 400 V CA 3 x 250 A 4 % @ 400 V CA
LR3 40-5/250 3 x 400 V CA 3 x 250 A 5 % @ 400 V CA
LR3 40-3/300 3 x 400 V CA 3 x 300 A 3 % @ 400 V CA
LR3 40-4/300 3 x 400 V CA 3 x 300 A 4 % @ 400 V CA
LR3 40-5/300 3 x 400 V CA 3 x 300 A 5 % @ 400 V CA
LR3 40-3/400 3 x 400 V CA 3 x 400 A 3 % @ 400 V CA
LR3 40-4/400 3 x 400 V CA 3 x 400 A 4 % @ 400 V CA
LR3 40-5/400 3 x 400 V CA 3 x 400 A 5 % @ 400 V CA
LR3 40-3/500 3 x 400 V CA 3 x 500 A 3 % @ 400 V CA
LR3 40-4/500 3 x 400 V CA 3 x 500 A 4 % @ 400 V CA
LR3 40-5/500 3 x 400 V CA 3 x 500 A 5 % @ 400 V CA
LR3 40-3/630 3 x 400 V CA 3 x 630 A 3 % @ 400 V CA
LR3 40-4/630 3 x 400 V CA 3 x 630 A 4 % @ 400 V CA
LR3 40-5/630 3 x 400 V CA 3 x 630 A 5 % @ 400 V CA
LR3 40-3/710 3 x 400 V CA 3 x 710 A 3 % @ 400 V CA
LR3 40-4/710 3 x 400 V CA 3 x 710 A 4 % @ 400 V CA
LR3 40-5/710 3 x 400 V CA 3 x 710 A 5 % @ 400 V CA
LR3 40-3/800 3 x 400 V CA 3 x 800 A 3 % @ 400 V CA
LR3 40-4/800 3 x 400 V CA 3 x 800 A 4 % @ 400 V CA
LR3 40-5/800 3 x 400 V CA 3 x 800 A 5 % @ 400 V CA
LR3 40-3/1000 3 x 400 V CA 3 x 1000 A 3 % @ 400 V CA
LR3 40-4/1000 3 x 400 V CA 3 x 1000 A 4 % @ 400 V CA
LR3 40-5/1000 3 x 400 V CA 3 x 1000 A 5 % @ 400 V CA
LR3 40-3/1200 3 x 400 V CA 3 x 1200 A 3 % @ 400 V CA
LR3 40-4/1200 3 x 400 V CA 3 x 1200 A 4 % @ 400 V CA
LR3 40-5/1200 3 x 400 V CA 3 x 1200 A 5 % @ 400 V CA
LR3 40-3/1400 3 x 400 V CA 3 x 1400 A 3 % @ 400 V CA
LR3 40-4/1400 3 x 400 V CA 3 x 1400 A 4 % @ 400 V CA
LR3 40-5/1400 3 x 400 V CA 3 x 1400 A 5 % @ 400 V CA
LR3 40-3/1600 3 x 400 V CA 3 x 1600 A 3 % @ 400 V CA
LR3 40-4/1600 3 x 400 V CA 3 x 1600 A 4 % @ 400 V CA
LR3 40-5/1600 3 x 400 V CA 3 x 1600 A 5 % @ 400 V CA
Illustration de BLOCK Article: LR3 40-3/250

Spécifications techniques pour LR3 40-3/250

Données de fonctionnement
Tension nominale 3 x 400 V CA
Tension nominale (IEC) 3 x 690 V CA
Tension nominale (UL) 3 x 600 V CA
Tension de court-circuit uK 3 % @ 400 V CA
Chute de tension 6,9 V CA
Courant nominale 3 x 250 A
Fréquence nominale 50 - 60 Hz
Inductance 0,088 mH
Déviation de l'inductivité ±10%
Données sortie
Perte d'alimentation max. veille/charge nominale 604,8 W
Admission
Agréments cURus
Environnement
Température ambiante De -10 °C à +40 °C
Méthode de refroidissement AN
Sécurité et protection
Type Ouvert
Classe du système d'isolation IEC=F, UL=class 155
Indice de protection IP 00
Classe de sécurité (préparée) I
Tension d'essai 4000 V CA
Raccordement et montage
Phase de connexion cuivre plat
Bornes de terre pour M8
Méthode de fixation Platine de fixation
Vis de fixation M8
Dimensions et poids
Large 352 mm
Hauteur 260 mm
Profondeur 144 mm
Poids 32,00 kg

Informations sur la série LR3 400

Informations générales
  • Tension assignée 3 x 400 V CA
  • Courant assigné 3 x 2 - 3 x 1 600 A
  • Tension de court-circuit (uK) 3 - 5 %
  • Indice de protection IP 00
  • Température ambiante de -10 °C à +40 °C
  • Inductance 0,019 - 18,500 mH
  • Classe d’isolation B, F ou H
Avantages
  • Utilisable comme réactance de ligne, inductance de commutation, réactance CPR
  • Garantie d’une tension de court-circuit de 3, 4 ou 5 % sur le réseau
  • Limitation du courant de démarrage
  • Augmentation de la durée de vie pour les consommateurs
  • Ondulation réduite
  • Tenue aux coupures du réseau
  • Limitation du courant de crête
  • Très bonne protection contre la corrosion et faible développement du bruit grâce à l’imprégnation sous vide
  • Anneaux de levage intégrés
  • Garantie d'une tension de court-circuit de 2 - 5 % sur le réseau
  • Anneaux de levage intégrés

Nos recommandations pour vous

BLOCK Produit: LR3A 40-3/250
LR3A 40-3/250
Inductance de ligne, triphasée, aluminium
3 x 400 V CA, 3 x 90 – 3 x 1600 A, 0,019 – 14,700 mH, Utilisable comme réactance de ligne, inductance de commutation, réactance CPR
vers les accessoires
BLOCK Produit: HLD 110-500/250
HLD 110-500/250
Filtre d’antiparasitage, triphasé
3 x 520 V CA, 3 x 8 – 3 x 250 A, Courant de fuite 20.00 - 37.00 mA, Pour une suppression améliorée des interférences électromagnétiques
vers les accessoires
BLOCK Produit: HFM-FB 200-400
HFM-FB 200-400
Filtre anti-harmonique
3 x 400 V CA, 3 x 10,00 – 3 x 433,00 A, 5 – 250 kW, Cos(phi)>0,95 au niveau du courant nominal
vers les accessoires