HFM-FB 300-400

Harmonic filter HFM-FB

Version HFM-FB 300-400
Rated voltage 3 x 400 Vac Rated current 3 x 433,00 A Rated load power 335.256 HP
Version Rated voltage Rated current Rated load power
HFM-FB 7-400 3 x 400 Vac 3 x 10.00 A 6.71 HP
HFM-FB 13-400 3 x 400 Vac 3 x 19.00 A 10.06 HP
HFM-FB 18-400 3 x 400 Vac 3 x 26.00 A 14.75 HP
HFM-FB 24-400 3 x 400 Vac 3 x 35.00 A 20.12 and 24.81 HP
HFM-FB 30-400 3 x 400 Vac 3 x 43.00 A 29.50 HP
HFM-FB 50-400 3 x 400 Vac 3 x 72.00 A 40.23 and 49.62 HP
HFM-FB 70-400 3 x 400 Vac 3 x 101.00 A 73.76 HP
HFM-FB 100-400 3 x 400 Vac 3 x 144.00 A 100.58 HP
HFM-FB 125-400 3 x 400 Vac 3 x 180.00 A 120.692 HP
HFM-FB 150-400 3 x 400 Vac 3 x 217.00 A 147.512 HP
HFM-FB 200-400 3 x 400 Vac 3 x 289.00 A 214.564 HP
HFM-FB 225-400 3 x 400 Vac 3 x 325.00 A 241.384 HP
HFM-FB 255-400 3 x 400 Vac 3 x 370,00 A 268.204 HP
HFM-FB 300-400 3 x 400 Vac 3 x 433,00 A 335.256 HP
Image of BLOCK Item: HFM-FB 300-400
Technical files Data sheet Approvals / Manufacturer's declaration EU-Declaration of Conformity

Technical Data for HFM-FB 300-400

Operating data
Rated current 3 x 433,00 A
Rated voltage 3 x 400 Vac
Voltage range 380 - 420 Vac
Rated frequency 50 Hz
THD-I 7 % typ at nominal load
Rated load power 335.256 HP
Description of the load Balanced load by inverter
Overrating Capacity 150 % for 60 sec. every 10 min.
Efficiency 99 %
Approvals
Approvals cURus
Environment
Ambient temperature 14 °F to + 104 °F,
without condensation
MTBF @ 122 °F/500 V (Mil-HB-217F) >200.000 h
Safety and protection
Type Metal enclosure
Insulation class IEC=F, UL=class 155
Protection index IP 00
Safety class I
SCCR 100 kA
Terminal and mounting
Connection type for M8
Fixing method Mounting lugs
Measures and weights
Depth 20.87 inch
Height 16.54 inch
Width 53.74 inch
Weight 853.19 lbs
Notes
* IE2 efficiencies of the motors and an efficiency
>96 % assumed

Information for HFM-FB 400 series

General Data
  • Load rated capacity 5 - 250 kW
  • SCCR 100 kA (without preliminary fuse)
  • Degree of protection IP 00
  • Ambient temperature -10 °C to +40 °C
  • Insulation class F
  • 7 % typ. at nominal load
  • Rated current 3 x 10.00 - 3 x 433.00 A
  • Rated voltage 3 x 400 Vac
Benefits
  • Support in the compliance with IEEE 519, D-A-CH-CZ
  • Sinusoidal current consumption from the main in devices with uncontrolled B6U diode rectifiers or controlled B6C thyristor bridges
  • Compliance with EN 61000-3-2, EN 61000-3-12
  • Power factor >0.95 at rated current
  • Hardly any intermediate circuit voltage dip by comparison with a 4 % uK line reactor
  • Use of the HFM as a central hum filter for multiple converters possible

Our recommendations for you

BLOCK product: LR3 40-4/500
LR3 40-4/500
Line reactor, three-phase
3 x 400 Vac, 3 x 2 – 3 x 1600 A, 0.019 – 18.500 mH, Use as line reactor, commutating reactor or PFC reactor
View accessory
BLOCK product: HLD 103-500/750
HLD 103-500/750
Radio interference suppression filter, three-phase
3 x 520 Vac, 3 x 270 – 3 x 1800 A, Leakage current 60.00 mA, For enhanced EMI suppression
View accessory