HFD 510-400/16 - no longer available
Radio interference suppression filter HFD 510
Version HFD 510-400/16 - no longer available
Rated voltage
3 x 480 Vac
Rated current
3 x 16 A
Leakage current (50 Hz)*
19 mA
Version | Rated voltage | Rated current | Leakage current (50 Hz)* | |
---|---|---|---|---|
HFD 510-400/8 - no longer available | 3 x 480 Vac | 3 x 8 A | 4 mA | |
HFD 510-400/16 - no longer available | 3 x 480 Vac | 3 x 16 A | 19 mA | |
HFD 510-400/25 - no longer available | 3 x 480 Vac | 3 x 25 A | 17 mA | |
HFD 510-400/35 - no longer available | 3 x 480 Vac | 3 x 35 A | 22 mA | |
HFD 510-400/50 - no longer available | 3 x 480 Vac | 3 x 50 A | 18 mA | |
HFD 510-400/80 - no longer available | 3 x 480 Vac | 3 x 80 A | 31 mA | |
HFD 510-400/180 - no longer available | 3 x 480 Vac | 3 x 180 A | 40 mA | |
HFD 510-500/8 | 3 x 520 Vac | 3 x 8 A | 4 mA | |
HFD 510-500/16 | 3 x 520 Vac | 3 x 16 A | 20 mA | |
HFD 510-500/25 | 3 x 520 Vac | 3 x 25 A | 18 mA | |
HFD 510-500/35 | 3 x 520 Vac | 3 x 35 A | 24 mA | |
HFD 510-500/50 | 3 x 520 Vac | 3 x 50 A | 20 mA | |
HFD 510-500/80 | 3 x 520 Vac | 3 x 80 A | 33 mA | |
HFD 510-500/130 | 3 x 520 Vac | 3 x 130 A | 42 mA | |
HFD 510-500/180 | 3 x 520 Vac | 3 x 180 A | 43 mA |
DOWNLOADS
Technical Data for HFD 510-400/16 - no longer available
Operating data | |
---|---|
Rated voltage | 3 x 480 Vac |
Voltage range | 0 - 3 x 480 Vac |
Rated current | 3 x 16 A |
Leakage current (50 Hz)* | 19 mA |
Leakage current (50 Hz)** | 178 mA |
Rated frequency | 50 - 60 Hz |
Overrating Capacity | 150 %, shortly |
Environment | |
---|---|
Ambient temperature max. | 104.0 °F |
Climatic category | 25/085/21 [in accordance with EN 60068-1] |
Safety and protection | |
---|---|
Type | Metal enclosure |
Protection index | IP 20 |
Safety class (prepared) | I |
Test voltage | 2150 Vdc Phase/Phase, 2700 Vdc Phase/PE |
Terminal and mounting | |
---|---|
Terminals phase | Screw clamp, 4 mm² |
Connection type | Bolt, M5 |
Fixing method | Mounting lugs |
Measures and weights | |
---|---|
Width | 12.01 inch |
Height | 5.59 inch |
Depth | 2.17 inch |
Weight | 4.19 lbs |
Notes | |
---|---|
* | Leakage current measured against the maximum permissible input voltage fluctuation in accordance with IEC 38 ±10 % |
** | Leakage current by loss of two phases |
Information for HFD 510 series
General Data
- Rated current 3 x 8 - 3 x 180 A
- Rated voltage 3 x 520 Vac
- Voltage range 0 - 3 x 480 - 520 Vac
- Leakage current 4.00 - 43.00 mA
- Degree of protection IP 20
Benefits
- Increase in the interference immunity of the connected equipment
- For the highest EMI suppression
- Two-stage filter concept
- Efficient filter effect against line-bound interference emissions