FL 24/8
Safety isolating transformer
Version FL 24/8
Rated input voltage
2 x 115 Vac
Rated output voltage
2 x 8 Vac
Power
24 VA
Version | Rated input voltage | Rated output voltage | Power | |
---|---|---|---|---|
FL 2/5 | 2 x 115 Vac | 2 x 5 Vac | 2 VA | |
FL 2/6 | 2 x 115 Vac | 2 x 6 Vac | 2 VA | |
FL 2/8 | 2 x 115 Vac | 2 x 8 Vac | 2 VA | |
FL 2/9 | 2 x 115 Vac | 2 x 9 Vac | 2 VA | |
FL 2/12 | 2 x 115 Vac | 2 x 12 Vac | 2 VA | |
FL 2/15 | 2 x 115 Vac | 2 x 15 Vac | 2 VA | |
FL 2/24 | 2 x 115 Vac | 2 x 24 Vac | 2 VA | |
FL 4/5 | 2 x 115 Vac | 2 x 5 Vac | 4 VA | |
FL 4/6 | 2 x 115 Vac | 2 x 6 Vac | 4 VA | |
FL 4/8 | 2 x 115 Vac | 2 x 8 Vac | 4 VA | |
FL 4/9 | 2 x 115 Vac | 2 x 9 Vac | 4 VA | |
FL 4/12 | 2 x 115 Vac | 2 x 12 Vac | 4 VA | |
FL 4/15 | 2 x 115 Vac | 2 x 15 Vac | 4 VA | |
FL 4/18 | 2 x 115 Vac | 2 x 18 Vac | 4 VA | |
FL 4/24 | 2 x 115 Vac | 2 x 24 Vac | 4 VA | |
FL 6/5 | 2 x 115 Vac | 2 x 5 Vac | 6 VA | |
FL 6/6 | 2 x 115 Vac | 2 x 6 Vac | 6 VA | |
FL 6/8 | 2 x 115 Vac | 2 x 8 Vac | 6 VA | |
FL 6/9 | 2 x 115 Vac | 2 x 9 Vac | 6 VA | |
FL 6/12 | 2 x 115 Vac | 2 x 12 Vac | 6 VA | |
FL 6/15 | 2 x 115 Vac | 2 x 15 Vac | 6 VA | |
FL 6/18 | 2 x 115 Vac | 2 x 18 Vac | 6 VA | |
FL 6/24 | 2 x 115 Vac | 2 x 24 Vac | 6 VA | |
FL 8/6 | 2 x 115 Vac | 2 x 6 Vac | 8 VA | |
FL 8/8 | 2 x 115 Vac | 2 x 8 Vac | 8 VA | |
FL 8/9 | 2 x 115 Vac | 2 x 9 Vac | 8 VA | |
FL 8/12 | 2 x 115 Vac | 2 x 12 Vac | 8 VA | |
FL 8/15 | 2 x 115 Vac | 2 x 15 Vac | 8 VA | |
FL 8/18 | 2 x 115 Vac | 2 x 18 Vac | 8 VA | |
FL 8/24 | 2 x 115 Vac | 2 x 24 Vac | 8 VA | |
FL 10/5 | 2 x 115 Vac | 2 x 5 Vac | 10 VA | |
FL 10/6 | 2 x 115 Vac | 2 x 6 Vac | 10 VA | |
FL 10/8 | 2 x 115 Vac | 2 x 8 Vac | 10 VA | |
FL 10/9 | 2 x 115 Vac | 2 x 9 Vac | 10 VA | |
FL 10/12 | 2 x 115 Vac | 2 x 12 Vac | 10 VA | |
FL 10/15 | 2 x 115 Vac | 2 x 15 Vac | 10 VA | |
FL 10/18 | 2 x 115 Vac | 2 x 18 Vac | 10 VA | |
FL 10/24 | 2 x 115 Vac | 2 x 24 Vac | 10 VA | |
FL 14/5 | 2 x 115 Vac | 2 x 5 Vac | 14 VA | |
FL 14/6 | 2 x 115 Vac | 2 x 6 Vac | 14 VA | |
FL 14/8 | 2 x 115 Vac | 2 x 8 Vac | 14 VA | |
FL 14/9 | 2 x 115 Vac | 2 x 9 Vac | 14 VA | |
FL 14/12 | 2 x 115 Vac | 2 x 12 Vac | 14 VA | |
FL 14/15 | 2 x 115 Vac | 2 x 15 Vac | 14 VA | |
FL 14/18 | 2 x 115 Vac | 2 x 18 Vac | 14 VA | |
FL 14/24 | 2 x 115 Vac | 2 x 24 Vac | 14 VA | |
FL 18/5 | 2 x 115 Vac | 2 x 5 Vac | 18 VA | |
FL 18/6 | 2 x 115 Vac | 2 x 6 Vac | 18 VA | |
FL 18/8 | 2 x 115 Vac | 2 x 8 Vac | 18 VA | |
FL 18/9 | 2 x 115 Vac | 2 x 9 Vac | 18 VA | |
FL 18/12 | 2 x 115 Vac | 2 x 12 Vac | 18 VA | |
FL 18/15 | 2 x 115 Vac | 2 x 15 Vac | 18 VA | |
FL 18/18 | 2 x 115 Vac | 2 x 18 Vac | 18 VA | |
FL 18/24 | 2 x 115 Vac | 2 x 24 Vac | 18 VA | |
FL 24/5 | 2 x 115 Vac | 2 x 5 Vac | 24 VA | |
FL 24/6 | 2 x 115 Vac | 2 x 6 Vac | 24 VA | |
FL 24/8 | 2 x 115 Vac | 2 x 8 Vac | 24 VA | |
FL 24/9 | 2 x 115 Vac | 2 x 9 Vac | 24 VA | |
FL 24/12 | 2 x 115 Vac | 2 x 12 Vac | 24 VA | |
FL 24/15 | 2 x 115 Vac | 2 x 15 Vac | 24 VA | |
FL 24/18 | 2 x 115 Vac | 2 x 18 Vac | 24 VA | |
FL 24/24 | 2 x 115 Vac | 2 x 24 Vac | 24 VA | |
FL 30/5 | 2 x 115 Vac | 2 x 5 Vac | 30 VA | |
FL 30/6 | 2 x 115 Vac | 2 x 6 Vac | 30 VA | |
FL 30/8 | 2 x 115 Vac | 2 x 8 Vac | 30 VA | |
FL 30/9 | 2 x 115 Vac | 2 x 9 Vac | 30 VA | |
FL 30/12 | 2 x 115 Vac | 2 x 12 Vac | 30 VA | |
FL 30/15 | 2 x 115 Vac | 2 x 15 Vac | 30 VA | |
FL 30/18 | 2 x 115 Vac | 2 x 18 Vac | 30 VA | |
FL 30/24 | 2 x 115 Vac | 2 x 24 Vac | 30 VA | |
FL 42/5 | 2 x 115 Vac | 2 x 5 Vac | 42 VA | |
FL 42/6 | 2 x 115 Vac | 2 x 6 Vac | 42 VA | |
FL 42/8 | 2 x 115 Vac | 2 x 8 Vac | 42 VA | |
FL 42/9 | 2 x 115 Vac | 2 x 9 Vac | 42 VA | |
FL 42/12 | 2 x 115 Vac | 2 x 12 Vac | 42 VA | |
FL 42/15 | 2 x 115 Vac | 2 x 15 Vac | 42 VA | |
FL 42/18 | 2 x 115 Vac | 2 x 18 Vac | 42 VA | |
FL 42/24 | 2 x 115 Vac | 2 x 24 Vac | 42 VA | |
FL 52/5 | 2 x 115 Vac | 2 x 5 Vac | 52 VA | |
FL 52/6 | 2 x 115 Vac | 2 x 6 Vac | 52 VA | |
FL 52/8 | 2 x 115 Vac | 2 x 8 Vac | 52 VA | |
FL 52/9 | 2 x 115 Vac | 2 x 9 Vac | 52 VA | |
FL 52/12 | 2 x 115 Vac | 2 x 12 Vac | 52 VA | |
FL 52/15 | 2 x 115 Vac | 2 x 15 Vac | 52 VA | |
FL 52/18 | 2 x 115 Vac | 2 x 18 Vac | 52 VA | |
FL 52/24 | 2 x 115 Vac | 2 x 24 Vac | 52 VA |
Technical Data for FL 24/8
Input | |
---|---|
Rated input voltage | 2 x 115 Vac |
Rated frequency | 50 - 60 Hz |
Output | |
---|---|
Rated output voltage | 2 x 8 Vac |
Power | 24 VA |
No-load voltage (app. x factor) | 1.20 |
No-load loss (typ.) | 1.6 W |
Efficiency | 77 % |
Standards | |
---|---|
Classification | Safety isolating transformer |
Approvals | |
---|---|
Approvals | cURus, VDE |
Environment | |
---|---|
Ambient temperature max. | 104.0 °F |
Safety and protection | |
---|---|
Type | Encapsulated |
Insulation class | VDE=E, UL=class 105 |
Protection index | IP 00 |
Safety class (prepared) | II |
Short circuit strength | non-short-circuit proof |
Terminal and mounting | |
---|---|
Terminals | Pins for PCB |
Measures and weights | |
---|---|
Depth | 2.68 inch |
Height | 1.24 inch |
Width | 2.24 inch |
Core type | UI 39/17 |
Weight | 0.99 lbs |
Information for FL series
General Data
- Rated power 2 - 52 VA
- Efficiency up to 81 %
- Insulation class E
- Maximum ambient temperature 104 °F / 40 °C
- Rated output voltage 2 x 5 - 2 x 24 Vac
- Rated input voltage 2 x 115 Vac
- Degree of protection IP 00
Benefits
- Dual output voltage for series or parallel connection
- Minimum size at high output
- Dual input voltage for series or parallel connection
- Permanent corrosion protection, high insulation value and maximum electrical reliability due to XtraDenseFill resin encapsulation
- Self-extinguishing potting material
- Low height