Rated input voltage 2 x 115 Vac Rated output voltage 2 x 12 Vac Power 2 VA
Version Rated input voltage Rated output voltage Power
AVB 0,35/2/6 2 x 115 Vac 2 x 6 Vac 0.35 VA
AVB 0,35/2/9 2 x 115 Vac 2 x 9 Vac 0.35 VA
AVB 0,35/2/12 2 x 115 Vac 2 x 12 Vac 0.35 VA
AVB 0,35/2/15 2 x 115 Vac 2 x 15 Vac 0.35 VA
AVB 0,35/2/18* Discontinued line - not for new designs 2 x 115 Vac 2 x 18 Vac 0.35 VA
AVB 0,35/2/24* Discontinued line - not for new designs 2 x 115 Vac 2 x 24 Vac 0.35 VA
AVB 0,5/2/6 2 x 115 Vac 2 x 6 Vac 0.5 VA
AVB 0,5/2/8 Discontinued line - not for new designs 2 x 115 Vac 2 x 8 Vac 0.5 VA
AVB 0,5/2/9 2 x 115 Vac 2 x 9 Vac 0.5 VA
AVB 0,5/2/12 2 x 115 Vac 2 x 12 Vac 0.5 VA
AVB 0,5/2/15 2 x 115 Vac 2 x 15 Vac 0.5 VA
AVB 0,5/2/18* Discontinued line - not for new designs 2 x 115 Vac 2 x 18 Vac 0.5 VA
AVB 0,5/2/24* Discontinued line - not for new designs 2 x 115 Vac 2 x 24 Vac 0.5 VA
AVB 1,0/2/6 2 x 115 Vac 2 x 6 Vac 1 VA
AVB 1,0/2/9 2 x 115 Vac 2 x 9 Vac 1 VA
AVB 1,0/2/12 2 x 115 Vac 2 x 12 Vac 1 VA
AVB 1,0/2/15 Discontinued line - not for new designs 2 x 115 Vac 2 x 15 Vac 1 VA
AVB 1,0/2/18 2 x 115 Vac 2 x 18 Vac 1 VA
AVB 1,0/2/24 2 x 115 Vac 2 x 24 Vac 1 VA
AVB 1,5/2/6 2 x 115 Vac 2 x 6 Vac 1.5 VA
AVB 1,5/2/8 2 x 115 Vac 2 x 8 Vac 1.5 VA
AVB 1,5/2/9 2 x 115 Vac 2 x 9 Vac 1.5 VA
AVB 1,5/2/12 2 x 115 Vac 2 x 12 Vac 1.5 VA
AVB 1,5/2/15 2 x 115 Vac 2 x 15 Vac 1.5 VA
AVB 1,5/2/18 2 x 115 Vac 2 x 18 Vac 1.5 VA
AVB 1,5/2/24 2 x 115 Vac 2 x 24 Vac 1.5 VA
AVB 2,0/2/12 Discontinued line - not for new designs 2 x 115 Vac 2 x 12 Vac 2 VA
AVB 2,3/2/6 2 x 115 Vac 2 x 6 Vac 2.3 VA
AVB 2,3/2/8 2 x 115 Vac 2 x 8 Vac 2.3 VA
AVB 2,3/2/9 2 x 115 Vac 2 x 9 Vac 2.3 VA
AVB 2,3/2/12 2 x 115 Vac 2 x 12 Vac 2.3 VA
AVB 2,3/2/15 2 x 115 Vac 2 x 15 Vac 2.3 VA
AVB 2,3/2/18 2 x 115 Vac 2 x 18 Vac 2.3 VA
AVB 2,3/2/24 2 x 115 Vac 2 x 24 Vac 2.3 VA
AVB 3,2/2/6 2 x 115 Vac 2 x 6 Vac 3.2 VA
AVB 3,2/2/9 2 x 115 Vac 2 x 9 Vac 3.2 VA
AVB 3,2/2/12 2 x 115 Vac 2 x 12 Vac 3.2 VA
AVB 3,2/2/15 2 x 115 Vac 2 x 15 Vac 3.2 VA
AVB 3,2/2/18 2 x 115 Vac 2 x 18 Vac 3.2 VA
AVB 3,2/2/24 2 x 115 Vac 2 x 24 Vac 3.2 VA

Technical Data for AVB 2,0/2/12 Discontinued line - not for new designs

Input
Rated input voltage 2 x 115 Vac
Rated frequency 50 - 60 Hz
Output
Rated output voltage 2 x 12 Vac
Power 2 VA
No-load voltage (app. x factor) 1.43
No-load loss (typ.) 0.9 W
Efficiency 43 %
Standards
Classification Safety isolating transformer
Approvals
Approvals cURus
Environment
Ambient temperature max. 158.0 °F
Safety and protection
Type Encapsulated
Insulation class VDE=B, UL=class 105
Protection index IP 00
Safety class (prepared) II
Short circuit strength inherently short-circuit proof
Terminal and mounting
Terminals Pins for printed circuit boards
Pin (ø) 0.8
Measures and weights
Depth 1.27 inch
Height 1.06 inch
Width 1.07 inch
Core type EI 30/15,5
Weight 0.22 lbs

Information for AVB series

General Data
  • Insulation class B
  • Degree of protection IP 00
  • Efficiency up to 59 %
  • Maximum ambient temperature 158 °F / 70 °C (AVB 3,2 max. 122 °F / 50 °C)
  • Rated output voltage 6 - 2 x 24 Vac
  • Rated power 0.35 - 3.2 VA
  • Rated input voltage 2 x 115 Vac
Benefits
  • Permanent corrosion protection, high insulation value and maximum electrical reliability due to XtraDenseFill resin encapsulation
  • Inherently short-circuit proof
  • Minimum size at high output
  • Designed for high ambient temperatures
  • Dual input voltage for series or parallel connection
  • Self-extinguishing potting and hood material
  • Dual output voltage for series or parallel connection

Our recommendations for you

BLOCK product: FL 2/12
FL 2/12
Low profile transformer
Encapsulated, PRI 2 x 115 Vac, SEC 2 x 5 – 2 x 24 Vac , 2 – 52 VA
View accessory
BLOCK product: VB 2,0/2/12
VB 2,0/2/12
Short-circuit proof PCB transformer
Versions with dual output voltage, PRI 230 Vac, SEC 6 – 24 Vac, 0.35 – 3.2 VA
View accessory