EMC tests during development

The fully equipped BLOCK EMC testing laboratory, with its trained staff, not only tests and measures the company’s own products. BLOCK also offers EMC-relevant tests as a service to external customers. The laboratory is certified to DIN EN ISO 9001. The mobile EMC laboratories complement BLOCK's scope of services.

All products, such as transformers, reactors, power supplies and EMI filters, are developed in close collaboration with the customer and produced in line with market needs. They can be found wherever reliable mains interfaces are required. Our EMC testing laboratory acts as an independent business division. The laboratory focuses on EMC services in the field of generic technical standards for products in the capital goods industry.

Mobile EMC-equipment

Interference emissions

Type Standards
Harmonic emissions, I ≤ 16 A DIN EN 61000-3-2
Harmonic emissions, 16 A > I ≤ 62,5 A DIN EN 61000-3-12
Conducted emissions, 10 kHz – 30 MHz DIN EN 55011
Radiated emissions, 30 MHz – 1 GHz (3m) DIN EN 55011

Interference immunity

Type Standards
ESD DIN EN 61000-4-2
Electromagnetic fields, 80 MHz – 1 GHz DIN EN 61000-4-3
Burst DIN EN 61000-4-4
Surge DIN EN 61000-4-5
Conducted HF, 150 kHz – 80 MHz DIN EN 61000-4-6
Power fail DIN EN 61000-4-11