HFM-FB 260-480

Harmonic filter HFM-FB 480

Version HFM-FB 260-480
Rated voltage 3 x 480 Vac Rated current 3 x 325,00 A Rated load power* 230.0 kW
Version Rated voltage Rated current Rated load power*
HFM-FB 8-480 3 x 480 Vac 3 x 10.00 A 5.5 kW
HFM-FB 15-480 3 x 480 Vac 3 x 19.00 A 11.0 kW
HFM-FB 21-480 3 x 480 Vac 3 x 26.00 A 15.0 kW
HFM-FB 28-480 3 x 480 Vac 3 x 35.00 A 22.0 kW
HFM-FB 34-480 3 x 480 Vac 3 x 43.00 A 30.0 kW
HFM-FB 57-480 3 x 480 Vac 3 x 72.00 A 45.0 kW
HFM-FB 80-480 3 x 480 Vac 3 x 101.00 A 55.0 kW
HFM-FB 115-480 3 x 480 Vac 3 x 144.00 A 90.0 kW
HFM-FB 145-480 3 x 480 Vac 3 x 180.00 A 110.0 kW
HFM-FB 175-480 3 x 480 Vac 3 x 217.00 A 132.0 kW
HFM-FB 230-480 3 x 480 Vac 3 x 289,00 A 160.0 kW
HFM-FB 260-480 3 x 480 Vac 3 x 325,00 A 230.0 kW
HFM-FB 295-480 3 x 480 Vac 3 x 370,00 A 260.0 kW

Technical data for HFM-FB 260-480

Operating data
Rated current 3 x 325,00 A
Rated voltage 3 x 480 Vac
Rated frequency 60 Hz
THD-I 7 % typ at nominal load
Rated load power* 230.0 kW
Description of the load Balanced load by inverter
Overrating Capacity 150 % for 60 sec. every 10 min.
Efficiency 99.0 %
Approvals
Approvals cURus
Environment
Ambient temperature -10 °C to +40 °C,
without condensation
MTBF @ 50 °C/500 V (Mil-HB-217F) >200.000 h
Safety and protection
Type Metal enclosure
Insulation class IEC=F, UL=class 155
Protection index IP 00
Safety class I
SCCR 100 kA
Terminal and mounting
Terminals phase Screw Terminal, M16
Terminals PE for M8
Connection cross section [ mm² ] min. 95
Fixing method Mounting lugs
Measures and weights
Depth 454 mm
Height 420 mm
Width 1330 mm
Weight 240 kg
Notes
* IE2 efficiencies of the motors and an efficiency
>96 % assumed

Info on HFM-FB 480 series

General Data
  • Load rated capacity 10 - 384 HP
  • SCCR 100 kA (without preliminary fuse)
  • Degree of protection IP 00
  • Ambient temperature -10 °C to +40 °C
  • Insulation class F
  • THD-I 7 % typ. at nominal load
  • Rated current 3 x 10.00 - 3 x 433.00 A
  • Rated voltage 3 x 400 - 3 x 480 Vac
Benefits
  • Compliance with EN 61000-3-2, EN 61000-3-12
  • Sinusoidal current consumption from the main in devices with uncontrolled B6U diode rectifiers or controlled B6C thyristor bridges
  • Use of the HFM as a central sum filter for multiple converters possible
  • Support in the compliance with IEEE 519, D-A-CH-CZ
  • Cos(phi)>0.95 at rated current
  • Hardly any intermediate circuit voltage dip by comparison with a 4 % uK line reactor

Our recommendations for you

BLOCK product: LR3 48-5/250
LR3 48-5/250
Line reactor, three-phase
3 x 480 Vac, 3 x 2 – 3 x 1600 A, 0.014 - 18.500 mH, Use as line reactor, commutating reactor or PFC reactor
to accessory part
BLOCK product: HLD 103-500/270
HLD 103-500/270
Radio interference suppression filter, three-phase
3 x 520 Vac, 3 x 270 – 3 x 1800 A, Leakage current 60.00 mA, For enhanced requirements
to accessory part
BLOCK product: LR3 48-3/250
LR3 48-3/250
Line reactor, three-phase
3 x 480 Vac, 3 x 2 – 3 x 1600 A, 0.014 - 18.500 mH, Use as line reactor, commutating reactor or PFC reactor
to accessory part