HFM-FB 125-400

Harmonic filter HFM-FB

Version HFM-FB 125-400
Rated voltage 3 x 400 Vac Rated current 3 x 180.00 A Rated load power* 90.0 kW
Version Rated voltage Rated current Rated load power*
HFM-FB 7-400 3 x 400 Vac 3 x 10.00 A 5.0 kW
HFM-FB 13-400 3 x 400 Vac 3 x 19.00 A 7.5 kW
HFM-FB 18-400 3 x 400 Vac 3 x 26.00 A 11.0 kW
HFM-FB 24-400 3 x 400 Vac 3 x 35.00 A 15.0 and 18.5 kW
HFM-FB 30-400 3 x 400 Vac 3 x 43.00 A 22.0 kW
HFM-FB 50-400 3 x 400 Vac 3 x 72.00 A 30.0 and 37.0 kW
HFM-FB 70-400 3 x 400 Vac 3 x 101.00 A 55.0 kW
HFM-FB 100-400 3 x 400 Vac 3 x 144.00 A 75.0 kW
HFM-FB 125-400 3 x 400 Vac 3 x 180.00 A 90.0 kW
HFM-FB 150-400 3 x 400 Vac 3 x 217.00 A 110.0 kW
HFM-FB 200-400 3 x 400 Vac 3 x 289.00 A 160.0 kW
HFM-FB 225-400 3 x 400 Vac 3 x 325.00 A 180.0 kW
HFM-FB 255-400 3 x 400 Vac 3 x 370,00 A 200.0 kW
HFM-FB 300-400 3 x 400 Vac 3 x 433,00 A 250.0 kW
Image of %s BLOCK Item: HFM-FB 125-400
Technical files Data sheet Approvals / Manufacturer's declaration EU-Declaration of Conformity

Technical data for HFM-FB 125-400

Operating data
Rated current 3 x 180.00 A
Rated voltage 3 x 400 Vac
Voltage range 380 - 440 Vac
Rated frequency 50 Hz
THD-I 7 % typ at nominal load
Rated load power* 90.0 kW
Description of the load Balanced load by inverter
Overrating Capacity 150 % for 60 sec. every 10 min.
Efficiency 99.0 %
Environment
Ambient temperature -10 °C to +40 °C,
without condensation
MTBF @ 50 °C/500 V (Mil-HB-217F) >200.000 h
Safety and protection
Type Metal enclosure
Insulation class IEC=F, UL=class 155
Protection index IP 00
Safety class I
SCCR 100 kA
Terminal and mounting
Terminals phase Bolt terminal, M16, 240 mm²
Terminals PE for M8
Connection cross section [ mm² ] min. 95
Fixing method Mounting lugs
Measures and weights
Depth 454 mm
Height 420 mm
Width 1160 mm
Weight 178.0 kg
Notes
* IE2 efficiencies of the motors and an efficiency
>96 % assumed

Info on HFM-FB 400 series

General Data
  • Load rated capacity 5 - 250 kW
  • SCCR 100 kA (without preliminary fuse)
  • Degree of protection IP 00
  • Ambient temperature -10 °C to +40 °C
  • Insulation class F
  • 7 % typ. at nominal load
  • Rated current 3 x 10.00 - 3 x 433.00 A
  • Rated voltage 3 x 400 Vac
Benefits
  • Support in the compliance with IEEE 519, D-A-CH-CZ
  • Sinusoidal current consumption from the main in devices with uncontrolled B6U diode rectifiers or controlled B6C thyristor bridges
  • Compliance with EN 61000-3-2, EN 61000-3-12
  • Cos(phi)>0.95 at rated current
  • Hardly any intermediate circuit voltage dip by comparison with a 4 % uK line reactor
  • Use of the HFM as a central sum filter for multiple converters possible

Our recommendations for you

BLOCK product: HLD 110-500/180
HLD 110-500/180
Radio interference suppression filter, three-phase
3 x 520 Vac, 3 x 8 – 3 x 250 A, Leakage current 20.00 - 37.00 mA, For enhanced requirements
to accessory part
BLOCK product: LR3 40-4/200
LR3 40-4/200
Line reactor, three-phase
3 x 400 Vac, 3 x 2 – 3 x 1600 A, 0.019 – 18.500 mH, Use as line reactor, commutating reactor or PFC reactor