EB-2724-010-0F
1-Channel circuit breaker thermomagnetic, EasyB
Input rated voltage
24 Vdc
Output rated current
1 A, NEC Class 2
Version | Input rated voltage | Output rated current | ||
---|---|---|---|---|
EB-2724-010-0F | 24 Vdc | 1 A, NEC Class 2 | ||
EB-2724-020-0F | 24 Vdc | 2 A, NEC Class 2 | ||
EB-2724-030-0F | 24 Vdc | 3 A, NEC Class 2 | ||
EB-2724-040-0F | 24 Vdc | 4 A, NEC Class 2 | ||
EB-2724-060-0F | 24 Vdc | 6 A | ||
EB-2724-080-0F | 24 Vdc | 8 A | ||
EB-2724-100-0F | 24 Vdc | 10 A |
DOWNLOADS
Technical files
Manual
Instruction manual
Dimension sheet
Approvals / Manufacturer's declaration
UL 508 Listed USA (E219022)
UL 508 Listed Canada (E219022)
COC UL 508 & CSA 22.2
UL 2367 USA (E356250)
COA UL 2367 & CSA 22.2
COC UL 2367 & CSA 22.2
EAC approval
EU-Declaration of Conformity
CAD/CAE data
ePlan Macro
3D-CAD-Model (STEP)
Additional information
Brochure EasyB
eBreaker brochure
Technical data for EB-2724-010-0F
Input | |
---|---|
Input rated voltage | 24 Vdc |
Input voltage range | 18 - 30 Vdc |
Maximal residual ripple of supplied input voltage | 3 % |
Max. total input current | 1 A |
Max. input current for each pole of terminal | 10 A (-), 40 A (+) |
Required input voltage for turning-on of outputs | 17.5 Vdc (Turn-off Threshold 16.7 Vdc), ± 0.7 Vdc |
Max. power losses | 0,93 W |
Over voltage protection | Suppressor diode 33 Vdc |
Stand-by current | 29 mA @ 24 Vdc |
Power losses in stand-by mode | 0,69 W @ 24 V |
Turn on capacity | 20 mF @ 24 Vdc / 2,5 mm² / 2,5 m |
Output | |
---|---|
Output rated voltage | 24 Vdc |
Maximum voltage drop between input and output | 24 mV |
Initialization time of module | 27 ms |
Turn-on delay of outputs | 0 ms |
Waiting periode after switch-off of an output | 500 ms (Short circuit) … 5 s (Overload) |
Maximum turn-on capacity for each channel | 60 mF |
Parallel use of outputs | Not allowed |
Serial use of outputs | not allowed |
Resistance to reverse feed max. | 35 Vdc |
Output rated current | 1 A, NEC Class 2 |
Efficiency | 99.0 % |
Signaling | |
---|---|
Bus communication | Collective notification signal |
Status indicator | LED (red, green, orange) |
Signal output | Output status, short circuit proof high = Channel on, low = Channel off, fault |
Signal output (ON/OFF/Reset) | - |
Approvals | |
---|---|
Approvals | cURus, cULus |
Environment | |
---|---|
Type of cooling | Natural convection |
Ambient temperature | -25 °C … +70 °C |
Storage temperature | -25 °C … +85 °C |
Relative humidity | 5 … 96 %, without condensation |
Required minimum spacing (left/right) | 0 mm |
Required minimum spacing (over/under) | 30 mm |
Safety and protection | |
---|---|
Protection index | IP 20 |
Safety class | III, without PE connection |
Degree of pollution | 2 |
Terminal and mounting | |
---|---|
Terminals input, (spring clamp terminal) | max. 16 mm² |
Terminals output, (spring clamp terminal) | max 2,5 mm² (2 x "+") |
Terminals signalling, (spring clamp terminal) | max. 2,5 mm² |
Mounting position | horizontal for standard rail DIN TS35 |
Measures and weights | |
---|---|
Weight | 0.039 kg |
Width | 12 mm |
Height | 99 mm |
Depth | 60 mm |
Info on EasyB 1-Channel thermomagnetic, adjusted internal fuse series
General Data
- Protection index IP 20
- Ambient temperature -25 °C to +70 °C
- Collective notification signal
- Up to 40 fuse channels stackable side by side
- Thermomagnetic characteristic
- Multi-coloured LED and status display button
- 24 Vdc 1-channel circuit breaker system
- Efficiency up to 99 %
Benefits
- Additional load outputs through output expanders mountable sidewise
- Automatic channel assignment
- Undervoltage shutdown per channel
- 3 years warranty
- Internal fuse adapted to the tripping current