The fully equipped BLOCK EMC testing laboratory, with its trained staff, not only tests and measures the company’s own products. BLOCK also offers EMC-relevant tests as a service to external customers. The laboratory is certified to DIN EN ISO 9001. The mobile EMC laboratories complement BLOCK's scope of services.
All products, such as transformers, reactors, power supplies and EMI filters, are developed in close collaboration with the customer and produced in line with market needs. They can be found wherever reliable mains interfaces are required. Our EMC testing laboratory acts as an independent business division. The laboratory focuses on EMC services in the field of generic technical standards for products in the capital goods industry.

Mobile EMC-equipment
With our mobile EMC testing services BLOCK can optimise and measure your projects on site – throughout Europe.
Interference emissions
Type | Standards |
Electromagnetic compatibility: Interference emissions | |
Harmonic emissions, I ≤ 16 A | DIN EN 61000-3-2 |
Harmonic emissions, 16 A > I ≤ 62,5 A | DIN EN 61000-3-12 |
Flicker | DIN EN 61000-3-3 |
Conducted emissions, 10 kHz – 30 MHz | DIN EN 55011, DIN EN 55022 |
Radiated emissions, 30 MHz – 1 GHz (3m und 10m) | DIN EN 55011, DIN EN 55022 |
Interference immunity
Type | Standards |
Electromagnetic compatibility: Interference immunity | |
ESD | DIN EN 61000-4-2 |
Electromagnetic fields, 80 MHz – 1 GHz | DIN EN 61000-4-3 |
Burst | DIN EN 61000-4-4 |
Surge | DIN EN 61000-4-5 |
Conducted HF, 150 kHz – 80 MHz | DIN EN 61000-4-6 |
Power fail | DIN EN 61000-4-11 |
Harmonics | DIN EN 61000-4-13 |
Voltage fluctuations | DIN EN 61000-4-14 |
AC overlay at DC input | DIN EN 61000-4-17 |
Asymmetric supply voltage | DIN EN 61000-4-27 |
Frequency fluctuations | DIN EN 61000-4-28 |
Power fail at DC supply terminals | DIN EN 61000-4-29 |